Mitsubishi Outlander XL. Manual — part 432
COOLING FAN MOTOR CHECK
M11401000019USA0000010000
1.
Disconnect the fan motor connector.
ZC602533
Rariator fan motor
AA00
ZC602534
Condenser fan
motor
AA00
2.
Check that the fan motor runs when a positive battery terminal
is connected to the fan motor-side connector terminal number
1, and terminal number 2 is grounded. Also check to see that
there is no abnormal sound emitted from the fan motor at this
time.
3.
If the fan motor is defective, replace it (Refer to P.14-27).
THERMOSTAT
REMOVAL AND INSTALLATION
M11401000024USA0000010000
Pre-removal and Post-installation Operation
⦆
Engine Coolant Draining and Refilling (Refer to P.14-15).
⦆
Air Cleaner Removal and Installation (Refer to GROUP 15, Air Cleaner P.15-6).
⦆
Battery and Battery Tray Removal and Installation
ENGINE COOLING
14-19
ON-VEHICLE SERVICE
ZC600494
1
2
3
23 ± 6 N·m
17 ± 4 ft-lb
AA00
Removal steps
<<A>>
>>B<<
1.
Radiator lower hose connection
2.
Water inlet fitting
Removal steps
>>A<<
3.
Thermostat
REMOVAL SERVICE POINT
<<A>> RADIATOR LOWER HOSE DISCONNECTION
ZC6006480000
Mating marks
Make mating marks on the radiator hose and the hose clamp.
Disconnect the radiator hose.
14-20
ENGINE COOLING
THERMOSTAT
INSTALLATION SERVICE POINTS
>>A<< THERMOSTAT INSTALLATION
Make absolutely sure that no oil adheres to the rubber ring
of the thermostat. Also do not fold or scratch the rubber ring
during installation.
ZC5015940000
Jiggle valve
Rubber ring
Install the thermostat so that the jiggle valve is facing straight up.
Be careful not to fold or scratch the rubber ring.
>>B<< RADIATOR LOWER HOSE INSTALLATION
ZC6006490000
Mating marks
Projection
Water inlet fitting
1.
Insert each hose as far as the projection of the water inlet
fitting.
2.
Align the mating marks on the radiator hose and hose clamp,
and then connect the radiator hose.
INSPECTION
M11401000025USA0000010000
Thermostat Check
ZC600851AA00
1.
Immerse the thermostat in water, and heat the water while
stirring. Check the thermostat valve opening temperature.
Standard value: Valve opening temperature: 82 ± 1.5°
C (180 ± 3°F)
ENGINE COOLING
14-21
THERMOSTAT
ZC6008520000
Valve lift
2.
Check that the amount of valve lift is at the standard value
when the water is at the full-opening temperature.
NOTE:
Measure the valve height when the thermostat is
fully closed, and use this measurement to compare the
valve height when the thermostat is fully open.
Standard value:
Full-opening temperature: 95°C (203°F)
Amount of valve lift: 9.0 mm (0.35 inch)
WATER PUMP
REMOVAL AND INSTALLATION
M11401000027USA0000010000
Pre-removal and Post-installation Operation
⦆
Engine Coolant Draining and Refilling (Refer to P.14-15).
⦆
Timing Belt Removal and Installation (Refer to GROUP 11A, Timing Belt P.11A-49).
ZC600496
1
2
23 ± 6 N·m
17 ± 4 ft-lb
N
AA00
Removal steps
1.
Water pump
Removal steps
2.
Water pump gasket