Mitsubishi Montero (2004+). Manual — part 592
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-11
STEP 2. Check the dual pressure switch operation.
(1) Remove the dual pressure switch connector and connect
the high/low pressure side terminals located on the harness
side as shown in the illustration.
(2) Install a gauge manifold to the high-pressure side service
valve of the refrigerant line. (Refer to
(3) When the high/low pressure sides of the dual pressure
switch are at operation pressure (ON) and there is
continuity between the respective terminals.
Q: When the high/low pressure sides of the dual pressure
switch are at operation pressure (ON), is there
continuity between the respective terminals?
YES : Go to Step 3.
NO : Replace the dual pressure switch. Then go to Step 5.
STEP 3. Measure the automatic compressor controller
terminal voltage.
Refer to
Q: Is the automatic compressor controller terminal voltage
correct?
YES : Go to Step 4.
NO : Replace the automatic compressor controller. Then
go to Step 5.
STEP 4. Measure the powertrain control module terminal
voltage.
Refer to GROUP 13A, Diagnosis
− Check at the Powertrain
Control Module (PCM)
Q: Is the voltage correct?
YES : Go to Step 5.
NO : Replace the PCM. Then go to Step 5.
STEP 5. Retest the system.
Q: Does the system produce cool air?
YES : The procedure complete. (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
ITEM
OFF to ON
ON to OFF
Low-pressure side
kPa (psi)
223
± 27 (32.4 ±
3.9)
196
± 20 (28.4 ±
2.9)
High-pressure side
kPa (psi)
2,550
± 200 (369.9
± 29)
3,140
± 200
(455.5
± 29)
ACX00822
ON
OFF
196 ± 20
(284 ± 2.9)
223 ± 27
(32.4 ± 3.9)
2,550 ± 200
(369.9 ± 29)
3,140 ± 200
(455.5 ± 29)
kPa
(psi)
DUAL PRESSURE
SWITCH
AF
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-12
INSPECTION PROCEDURE 4: Blower Fan and Motor does not turn.
DIAGNOSIS
STEP 1. Check the front blower relay continuity.
Follow the table below to check the front blower relay for conti-
nuity.
Q: Is the front blower relay continuity in good condition?
YES : Go to Step 2.
NO : Replace the front blower relay. Then go to Step 5.
STEP 2. Check the blower motor operation.
When battery voltage is applied between the terminals, check
that the motor operates.
Q: Is there any abnormal noise?
YES : Go to Step 3.
NO : Replace the blower motor. Then go to Step 5.
BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
2
− 5
Open circuit
• Connect terminal 3 to the
positive battery terminal
• Connect terminal 1 to the
negative battery terminal
2
− 5
Less than 2
ohms
AC204714AB
FRONT BLOWER RELAY
AC001038 AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-13
STEP 3. Check the blower switch continuity.
Follow the table below to check the blower switch for continuity.
Q: Is there continuity at the blower switch?
YES : Go to Step 4.
NO : Replace the blower switch. Then go to Step 5.
STEP 4. Check the blower resistor resistance value.
Use an ohmmeter to measure the resistance between the ter-
minals as indicated below. Check that the measured value is at
the standard value.
Q: Is the measured value at the standard value?
YES : Go to Step 5.
NO : Replace the blower resistor. Then go to Step 5.
STEP 5. Retest the system.
Q: Do the blower fan and motor operate?
YES : The procedure complete (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
).
NO : Go to Step 1.
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
0 (OFF)
1
− 3, 3 − 4, 3 − 5, 3 − 6 Open circuit
1 (LO)
3
− 5
Less than 2 ohms
2 (ML)
1
− 3
Less than 2 ohms
3 (MH)
3
− 6
Less than 2 ohms
4 (HI)
3
− 4
Less than 2 ohms
AC001371
BLOWER SWITCH
ASSEMBLY
AB
MEASUREMENT TERMINAL
STANDARD VALUE
Ω
Between terminals 2 and 3 (LO) 2.79
Between terminals 1 and 2 (ML) 1.49
Between terminals 2 and 4 (MH) 0.36
AC002646
1 2
3 4
AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-14
INSPECTION PROCEDURE 5: Blower Fan and Motor does not Stop turning.
DIAGNOSIS
STEP 1. Check the harness wires between the blower
motor connector D-113, the blower resistor connector
D-115, and the blower switch connector D-101.
Q: Are the harness wires between the blower motor
connector D-113, the blower resistor connector D-115,
and the blower switch connector D-101 in good
condition?
YES : Go to Step 2.
NO : Repair the wiring harness. Then go to Step 4.
AC204170
CONNECTOR : D-101
BZ
HARNESS
SIDE
1
4
2
3
5
6
AC204189
CONNECTORS : D-113, D-115
D-113
AB
D-115
D-113
HARNESS SIDE
HARNESS SIDE
D-115
1
2
1
2
3
4