Mitsubishi Montero (2004+). Manual — part 593
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-15
STEP 2. Check the front blower relay continuity.
Follow the table below to check the front blower relay for conti-
nuity.
Q: Is there continuity at the front blower relay?
YES : Go to Step 3.
NO : Replace the front blower relay. Then go to Step 4.
STEP 3. Check the blower switch continuity.
Follow the table below to check the blower switch for continuity.
Q: Is there continuity at the blower switch?
YES : Go to Step 4.
NO : Replace the blower switch. Then go to Step 4.
STEP 4. Retest the system.
Q: Does the blower motor stop operating?
YES : The procedure complete (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
).
NO : Go to Step 1.
BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
2
− 5
Open circuit
• Connect terminal 3
to the positive
battery terminal
• Connect terminal 1
to the negative
battery terminal
2
− 5
Less than 2 ohms
AC204714AB
FRONT BLOWER RELAY
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
0 (OFF)
1
− 3, 3 − 4, 3 − 5, 3 − 6 Open circuit
1 (LO)
3
− 5
Less than 2 ohms
2 (ML)
1
− 3
Less than 2 ohms
3 (MH)
3
− 6
Less than 2 ohms
4 (HI)
3
− 4
Less than 2 ohms
AC001371
BLOWER SWITCH
ASSEMBLY
AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-16
INSPECTION PROCEDURE 6: When the A/C is Operating Condenser Fan does not turn.
DIAGNOSIS
STEP 1. Check the condenser fan control relay continuity.
Follow the table below to check the condenser fan control relay
for continuity.
Q: Is there continuity at the fan control relay?
YES : Go to Step 2.
NO : Replace the condenser fan control relay. Then go to
Step 4.
STEP 2. Check the condenser fan motor operation.
Follow the table below to check the condenser fan motor for
continuity.
Q: Is the condenser fan motor operating correctly?
YES : Go to Step 3.
NO : Replace the condenser fan motor. Then go to Step 3.
STEP 3. Measure the PCM terminal voltage.
Refer to GROUP 13A, Check at PCM terminals
.
Q: Is the PCM voltage correct?
YES : Go to Step 4.
NO : Replace the PCM. Then go to Step 4.
BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4
− 5
Open circuit
• Connect terminal 3
to the positive
battery terminal
• Connect terminal 1
to the negative
battery terminal
4
− 5
Less than 2 ohms
AC204715
3
1
4
5
AF
BATTERY
CONDENSER
FAN CONTROL
RELAY
CONNECT
POSITIVE BATTERY
TERMINAL TO
CONNECT
NEGATIVE BATTERY
TERMINAL TO
MOTOR
OPERATION
1
2
Rotates
ACX00845 AC
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-17
STEP 4. Retest the system.
NOTE: The condenser fan might not operate when there is an
air conditioning low load from the air conditioning condenser
control, so remove the negative battery terminal and then
check the symptoms after 5 minutes since initial start control
after reconnection.
Q: Is the condenser fan operating correctly?
YES : The procedure complete (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
).
NO : Go to Step 1.
INSPECTION PROCEDURE 7: Inside/Outside Air changeover is not possible.
DIAGNOSIS
STEP 1. Check the outside/inside air selection damper
control motor operation.
CAUTION
Disconnect the battery negative terminal when the damper
is in the inside/outside air position.
Check the outside/inside air selection damper control motor by
the following procedures.
Q: Is the outside/inside air selection damper control motor
operating correctly?
YES : Go to Step 2.
NO : Replace the outside/inside air selection damper
control motor. Then go to Step 4.
LEVER
POSITION
BATTERY
CONNECTION
LEVER
OPERATION
At the inside
air position
• Connect terminal 1
to the positive
battery terminal
• Connect terminal 2
to the negative
battery terminal
The lever moves
from the inside air
position to the
outside air position
At the outside
air position
• Connect terminal 1
to the positive
battery terminal
• Connect terminal 3
to the negative
battery terminal
The lever moves
from the outside air
position to the
inside air position
AC309178AB
OUTSIDE
AIR
INSIDE AIR
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-18
STEP 2. Check the outside/inside air selection switch
continuity.
Follow the table below to check the inside/outside air
changeover switch for continuity.
Q: Is there continuity at the outside/inside air selection
switch?
YES : Go to Step 3.
NO : Replace the outside/inside air selection switch. Then
go to Step 4.
STEP 3. Measure the automatic compressor controller
terminal voltage.
Refer to
Q: Is the automatic compressor controller terminal voltage
correct?
YES : Go to Step 4.
NO : Replace the automatic compressor controller. Then
go to Step 4.
STEP 4. Retest the system.
Q: Do the outside/inside air selection damper control
motor operate?
YES : The procedure complete (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
).
NO : Go to Step 1.
INSPECTION AT THE AUTOMATIC COMPRESSOR CONTROLLER TERMINAL
M1552010300613
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
Inside air
4
− 5
Open circuit
Outside air
4
− 5
Less than 2 ohms
AC001370
OFF
ON
BLOWER
SWITCH
ASSEMBLY
AB
28
27
23 24
26
25
21 22
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
AC101882
TERMINAL
NO.
INSPECTION ITEM
INSPECTION REQUIREMENT
NORMAL CONDITION
1
IG2 power supply
Ignition switch ON
Battery positive voltage
2
Input from air thermo
sensor to controller
Ignition switch and A/C switch: OFF
0 V
Ignition switch and A/C switch: ON
2
− 5 V