Mitsubishi Montero (2004+). Manual — part 650
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-89
INSPECTION PROCEDURE 7: Inside/Outside Air Changeover is not Possible.
Outside/Inside Air changeover Damper Motor Citcuit
AC204170
CONNECTORS : D-01, D-23
DS
D-23(B)
D-01
AC204171 AY
D-20
CONNECTOR : D-10
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-90
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991958: Scan Tool (MUT-III Sub Assembly)
• MB991824: Vehicle Communication Interface (V.C.I.)
• MB991827: MUT-III USB Cable
• MB991911: MUT-III Main Harness B (Vehicles without
CAN communication system)
STEP 1. Using scan tool MB991958, check actuator test
item 13 and item 14: Outside/inside air selection damper
control motor.
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958.
Carry out the actuator test.
Item 13 and 14: outside/inside air selection damper control
motor
Q: Does the check result show outside air (actuator test
item number: 13) or inside air (actuator test number:
14)?
YES : Got to Step 8.
NO : Go to Step 2.
AC204173
CONNECTORS : D-208, D-210
BF
D-208
D-210
AC307591 AB
MB991911
DATA LINK
CONNECTOR
MB991824
MB991827
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-91
STEP 2. Check the outside/inside air selection damper
control motor.
CAUTION
Disconnect the battery negative terminal when the damper
is in the inside/outside air position.
Check the outside/inside air selection damper control motor by
the following procedures.
Q: Is the check result normal?
YES : Got to Step 3.
NO : Replace the inside air/outside air changeover
damper motor. Check that the outside/inside air
selection damper control motor works normally.
LEVER POSITION BATTERY
CONNECTION
LEVER
OPERATION
At the inside air
position
• Connect
terminal 1 to the
positive battery
terminal
• Connect
terminal 2 to the
negative battery
terminal
The lever moves
from the inside air
position to the
outside air position
At the outside air
position
• Connect
terminal 1 to the
positive battery
terminal
• Connect
terminal 3 to the
negative battery
terminal
The lever moves
from the outside air
position to the
inside air position
2 3
1
AC001041AB
OUTSIDE
AIR
INSIDE AIR
AUTO A/C DIAGNOSIS
TSB Revision
AUTOMATIC AIR CONDITIONING
55B-92
STEP 3. Measure the voltage at outside/inside air selection
damper control motor connector D-10.
(1) Disconnect outside/inside air selection damper control
motor connector D-10, and measure the voltage at the
harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 1 and ground.
• The measured value should be approximately 12 volts
(battery positive voltage).
Q: Does the measured voltage correspond with this range?
YES : Go to Step 6.
NO : Go to Step 4.
STEP 4. Check outside/inside air selection damper control
motor connector D-10 for damage.
Q: Is outside/inside air selection damper control motor
connector D-10 in good condition?
YES : Go to Step 5.
NO : Repair or replace the connector. Refer to GROUP
00E, Harness Connector Inspection
that the outside/inside air changeover damper control
motor works normally.
STEP 5. Check the wiring harness between outside/inside
air selection damper control motor connector D-10
(terminal 1) and the ignition switch (IG2).
AC204171
CONNECTOR : D-10
AO
HARNESS SIDE
1
3 2
AC204738 CZ
HARNESS SIDE : D-10
1
3 2
AC204171
CONNECTOR : D-10
AO
HARNESS SIDE
1
3 2
AC204171
CONNECTOR : D-10
AO
HARNESS SIDE
1
3 2