Mitsubishi Montero (2004+). Manual — part 800
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-457
NOTE: Also check intermediate connectors D-26, D-28, junc-
tion block connectors D-207 and D-221 for loose, corroded, or
damaged terminals, or terminals pushed back in the connector.
If intermediate connector D-26, D-28, junction block connector
D-207 or D-221 is damaged, repair or replace the damaged
component(s) as described in GROUP, Harness Connector
Inspection
.
Q: Is the wiring harness between rear personal light (RH)
connector F-04 (terminal 1) and fusible link (1) in good
condition?
YES : Go to Step 41.
NO : Repair the wiring harness. Verify that the rear
personal light (RH) illuminates normally.
AC204188
CONNECTORS : D-26, D-28
D-28
AH
D-26
D-28
D-26
2 3
27
32
28
33
16
15
4 5
19
18
29
17
34
7 8
35
22
21
9 10
30
36
31
37
25
24
23
6
20
1
14
26
11
13
12
38
2 3
1
7
6
12
11
8
13
5
4
9 10
AC204191
CONNECTORS : D-207, D-221
D-207
AB
HARNESS SIDE
HARNESS SIDE
D-221
D-207
D-221
3
1
4
6 5
7
8
2
1
2
3
4
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-458
STEP 41. Check the wiring harness between rear personal
light (RH) connector F-04 (terminal 2) and ground.
NOTE: Also check intermediate connectors D-26 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector D-26 is damaged, repair or
replace the damaged component(s) as described in GROUP,
Harness Connector Inspection
.
Q: Is the wiring harness between rear personal light (LH)
connector (terminal 2) and ground in good condition?
YES : No action to be taken.
NO : Repair the wiring harness. Verify that the rear
personal light (RH) illuminates normally.
ACX02274
FUSIBLE LINK (1)
AE
BATTERY
AC204177
CONNECTOR: F-04
AO
HARNESS SIDE
F-04
AC204170
CONNECTOR : D-26
AG
2 3
1
7
6
12
11
8
13
5
4
9 10
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-459
INSPECTION PROCEDURE M-2: Interior Light: Dome light dimming function does not work normally.
NOTE: This troubleshooting procedure requires the
use of scan tool MB991958 and SWS monitor kit
MB991862. For details on how to use the SWS mon-
itor, refer to "How to use SWS monitor
.
CIRCUIT OPERATION
The ETACS-ECU operates the dome light dimming
function according to the following switches:
• Ignition switch (IG1)
• Key reminder switch
• Front door switches
• Driver's door lock actuator switch
.
TECHNICAL DESCRIPTION (COMMENT)
Is the dome lights do not dim normally, the input cir-
cuits from the switches described in "CIRCUIT
OPERATION" or the ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
• The key reminder switch may be defective
• The door switches may be defective
• The driver’s door lock actuator switch may be
defective
• The ETACS-ECU may be defective
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991958: Scan Tool (MUT-III Sub Assembly)
• MB991824: Vehicle Communication Interface (V.C.I.)
• MB991827: MUT-III USB Cable
• MB991911: MUT-III Main Harness B
• MB991813: SWS Monitor Kit
• MB991806: SWS Monitor Cartridge
• MB991812: SWS Monitor Harness (For Column-ECU)
• MB991822: Probe Harness
Interior Light Dimming Function
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-460
STEP 1. Verify the dome light.
If the dome light switch are moved to the "door interlock posi-
tion", the dome light should illuminate when either door is
opened.
Q: Do the dome light illuminate normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure M-1 "The dome light do
not illuminate or go out normally
STEP 2. Use scan tool MB991958 to select "ECU COMM
CHK" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958.
(1) Connect the special tool. Refer to "How to connect SWS
monitor
.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate scan tool MB991958 according to the procedure
below to display "ECU COMM CHK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHK."
(4) Scan tool MB991958 should show "OK" on the "ECU
COMM CHK" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed on the "ETACS ECU" menu?
YES : Go to Step 3.
NO : Refer to Inspection Procedure A-3 "Communication
with ETACS-ECU is not possible
AC309091
MB991911
MB991827
MB991824
AB
MB991806
MB991862
DATA LINK
CONNECTOR
(16-PIN)
DATA LINK
CONNECTOR
(13-PIN)