Mitsubishi Outlander GS45X. Manual — part 1081
DOOR
TSB Revision
BODY
42A-127
INSPECTION PROCEDURE B-7: Window Glass Lowers Automatically while it is Rising <Driver’s Side
Only>.
.
CIRCUIT OPERATION
If the sliding resistance is too great when the window is being
raised or the window glass encounters an object, the window
glass will lower by approximately 150 mm (5.9 in).
.
TROUBLESHOOTING HINTS
• Improperly adjusted door window glass
• Incorrectly installed or warped glass slider
• Malfunction of the power window motor
• Malfunction of the window regulator
DIAGNOSIS
STEP 1. Check the power window anti-trap function.
Check that the power window anti-trap function works normally
(Refer to
Q: Is the check result normal?
YES : Go to Step 2.
NO : Refer to
.
STEP 2. Check that the door window glasses are installed
correctly.
Check that the door window glasses are installed correctly.
Q: Is the check result normal?
YES : Go to Step 3.
NO : Adjust the door window glass (Refer to
Verify that the power window works normally.
STEP 3. Retest the system.
Check that the power window does not lower while it is being
raised.
Q: Is the check result normal?
YES : No action is necessary and testing is complete.
NO : Replace the power window motor of the defective
window. Verify that the power window works normally.
DOOR
TSB Revision
BODY
42A-128
CHECK AT ECU TERMINAL
M1429013600573
POWER WINDOW SWITCH TERMINAL CHECK
.
POWER WINDOW MAIN SWITCH
AC609433
E-19
AC
Terminal
No.
Check items
Check conditions
Normal conditions
1
Output to power window motor
(Passenger’s side)
−
−
2
Output to power window motor
(Driver’s side)
−
−
3
Output to power window motor
(Passenger’side)
−
−
4
Power supply
Power window relay: ON
Battery positive
voltage
5
Power supply
Always
Battery positive
voltage
6
Output to power window motor
(Driver’s side)
−
−
7
LIN communication line (between
ETACS-ECUs)
Always
0 to 12 V (pulse signal)
8
Input from power window motor
(pulse sensor signal)
When the power windows are
operating
0 to 5 V (pulse signal)
9
Input from power window motor
(pulse sensor ground)
−
0.5 V or less
10
Ground
Always
1 V or less
11
Input from power window motor
(pulse sensor signal)
When the power windows are
operating
0 to 5 V (pulse signal)
12
Input from power window motor
(power supply to pulse sensor)
When the power windows are
operating
5 V
13
−
−
−
14
−
−
−
15
Output to power window motor
(Rear right side)
−
−
16
−
−
−
17
Output to power window motor
(Rear right side)
−
−
18
Output to power window motor
(Rear left side)
−
−
19
Output to power window motor
(Rear left side)
−
−
DOOR
TSB Revision
BODY
42A-129
DOOR DIAGNOSIS
INTRODUCTION TO GLASS AND DOOR DIAGNOSIS
M1423007300296
Glass and door faults include water leaks and
improper opening and closing. Causes for these
faults can include faults in the glass, weatherstrip,
drain hole or door installation.
GLASS AND DOOR DIAGNOSTIC TROUBLESHOOTING STRATEGY
M1423006700354
Use these steps to plan your diagnostic strategy. If
you follow them carefully, you will be sure that you
have exhausted most of the possible ways to find a
glass and door fault.
1. Gather information from the customer.
2. Verify that the condition described by the
customer exists.
3. Find the malfunction by following the Symptom
Chart.
4. Verify malfunction is eliminated.
SYMPTOM CHART
M1423007000392
SYMPTOM PROCEDURES
INSPECTION PROCEDURE 1: Water Leak Through Door Window Glass
DIAGNOSIS
STEP 1. Check the window glass runchannel.
Q: Is the window glass runchannel in good condition?
YES :
Go to Step 2.
NO :
Replace the runchannel, then go to Step 4.
STEP 2. Check the door window glass
installation.
Q: Is the door window glass installed correctly?
YES :
Go to Step 3.
NO :
Reinstall the door window glass (Refer to
). Then go to Step 4.
STEP 3. Check the clearance at the top of the
door window glass.
Q: Is the clearance at the top of the door window
glass correct?
YES :
Go to Step 4.
NO :
Adjust the door window glass (Refer to
). Then go to Step 4.
STEP 4. Retest the system.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
The procedure is complete.
Symptom
Inspection
procedure
Reference page
Water leak through door window glass
1
Door window glass malfunction
2
Water leak through door edge
3
Water leak from door center
4
Door hard to open
5
Door does not open or close completely
6
Uneven gap between body
7
Wind noise around door
8
DOOR
TSB Revision
BODY
42A-130
INSPECTION PROCEDURE 2: Door Window Glass Malfunction
DIAGNOSIS
STEP 1. Check the door window glass
installation condition.
Q: Is the door window glass installed correctly?
YES :
Go to Step 2.
NO :
Reinstall the door window glass (Refer to
). Then go to Step 4.
STEP 2. Check the delta window glass.
Q: Is the delta window glass installed correctly?
YES :
Go to Step 3.
NO :
Repair or replace delta window glass, then
go to Step 4.
STEP 3. Inspect the window regulator assembly.
Q: Is the window regulator assembly installed
correctly?
YES :
Go to Step 4.
NO :
Repair or replace the window regulator
assembly, then go to Step 4.
STEP 4. Retest the system.
Q: Does the door window operate correctly?
YES :
The procedure is complete.
NO :
Return to Step 1.
INSPECTION PROCEDURE 3: Water Leak Through Door Edge
DIAGNOSIS
STEP 1. Check the door opening weatherstrips.
Q: Is the door opening weatherstrips in good
condition?
YES :
Go to Step 2.
NO :
Replace the door opening weatherstrips,
then go to Step 3.
STEP 2. Check the door fit (alignment).
Q: Is the door fit (alignment) correct?
YES :
Go to Step 3.
NO :
.
Then go to Step 3.
STEP 3. Retest the system.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
The procedure is complete.
INSPECTION PROCEDURE 4: Water Leak from Door Center
DIAGNOSIS
STEP 1. Check the drain hole.
Q: Is the drain hole clogged?
YES :
Clean the drain hole, then go to Step 3.
NO :
Go to Step 2.
STEP 2. Check the door opening weatherstrips.
Q: Is the door opening weatherstrips in good
condition?
YES :
Go to Step 3.
NO :
Repair or replace the door opening
weatherstrips, then go to Step 3.
STEP 3. Retest the system.
Q: Is any water leaking?
YES :
Return to Step 1.
NO :
The procedure is complete.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.