Dodge Neon / Neon SRT-4. Manual — part 490
TEST
ACTION
APPLICABILITY
3
NOTE: This test is for vehicles with VTSS. If this vehicle is not equipped
with VTSS, answer YES to the question and continue.
Turn the ignition off.
Disconnect the Remote Keyless Entry module connector.
Remove the driver door inner trim panel.
Disconnect the Cylinder Lock Switch connector.
Measure the resistance between ground and the driver Door Switch Mux circuit
(cavity 10).
Is the resistance below 8000.0 ohms?
All
Yes
→ Go To 4
No
→ Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
4
Turn the ignition off.
Disconnect the Door Lock Switch connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance between ground and the driver Door Switch Mux circuit
(cavity 10).
Is the resistance below 8000.0 ohms?
All
Yes
→ Repair the Driver Door Switch Mux circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Replace the Door Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
182
POWER DOOR LOCKS/RKE
DRIVER DOOR SWITCH SHORTED OR STUCK —
Continued
Symptom:
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUM-
BER
When Monitored and Set Condition:
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUMBER
When Monitored:
When the ignition is in the run position during Remote Keyless Entry
Module configuration.
Set Condition:
When the operator attempts to choose a configuration which is not
compatible with the part number. Example: Selecting BUX RKE when the module is a
Domestic part number, The RKE frequencies are not compatible.
POSSIBLE CAUSES
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUMBER
TEST
ACTION
APPLICABILITY
1
Ensure the module type corresponds with the correct module part number.
If the module type corresponds with the module part number the RKE module is
defective.
If there are no possible causes remaining, view repair.
All
Repair
Replace the Remote Keyless Entry Module.
Perform BODY VERIFICATION TEST - VER 1.
183
POWER DOOR LOCKS/RKE
Symptom:
INTERIOR DECKLID RELEASE SWITCH SHORTED OR STUCK
When Monitored and Set Condition:
INTERIOR DECKLID RELEASE SWITCH SHORTED OR STUCK
When Monitored:
Whenever the RKE module is connected and the battery is above 10.0
volts..
Set Condition:
When a decklid release input is present for more than 8 seconds.
POSSIBLE CAUSES
DTC PRESENT
DECKLID RELEASE SWITCH SHORT TO GROUND.
DECKLID RELEASE RELAY CONTROL CIRCUIT SHORT TO GROUND.
REMOTE KEYLESS ENTRY MODULE - SHORTED
TEST
ACTION
APPLICABILITY
1
With the DRBIII
t, erase DTCs.
Turn the ignition on.
Operate the decklid release from the interior switch.
With the DRBIII
t, read DTCs.
Does the DRBIII
t display: INTERIOR DECKLID RELEASE SWITCH SHORTED
OR STUCK?
All
Yes
→ Go To 2
No
→ The causes for setting this code are not present at this time. Using
the wiring diagram/schematic as a guide, inspect the wiring and
connectors.
Perform BODY VERIFICATION TEST - VER 1.
2
Disconnect the interior Decklid Release Switch connector.
Turn the ignition on.
Measure the voltage between ground and the Decklid Release Relay Control circuit
in the switch connector
Is the voltage above 10.0 volts?
All
Yes
→ Replace the Decklid Release Switch.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 3
184
POWER DOOR LOCKS/RKE
TEST
ACTION
APPLICABILITY
3
Disconnect the RKE module connector.
Disconnect the interior Decklid Release Switch connector.
Measure the resistance between ground and the Decklid Release Relay Control
circuit.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Decklid Release Relay Control circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Replace the Remote Keyless Entry module.
Perform BODY VERIFICATION TEST - VER 1.
185
POWER DOOR LOCKS/RKE
INTERIOR DECKLID RELEASE SWITCH SHORTED OR STUCK —
Continued
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.