Infiniti QX4 (R50). Manual — part 278
5
CHECK VACUUM CUT VALVE
1. Turn ignition switch OFF.
2. Remove vacuum cut valve.
3. Check vacuum cut valve as follows:
SEF379Q
a. Plug port C and D with fingers.
b. Apply vacuum to port A and check that there is no suction from port B.
c. Apply vacuum to port B and check that there is suction from port A.
d. Blow air in port B and check that there is a resistance to flow out of port A.
e. Open port C and D.
f. Blow air in port A check that air flows freely out of port C.
g. Blow air in port B check that air flows freely out of port D.
OK or NG
OK
©
GO TO 6.
NG
©
Replace vacuum cut valve.
6
CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve attached.
2. Check if water will drain from the EVAP canister.
SEF596U
Yes or No
Yes
©
GO TO 7.
No
©
GO TO 9.
7
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve attached.
The weight should be less than 1.8 kg (4.0 lb).
OK or NG
OK
©
GO TO 9.
NG
©
GO TO 8.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P1448 EVAPORATIVE EMISSION (EVAP) CANISTER VENT CONTROL
VALVE (OPEN)
Diagnostic Procedure (Cont’d)
EC-579
8
DETECT MALFUNCTIONING PART
Check the following.
I
EVAP canister for damage
I
EVAP hose between EVAP canister and water separator for clogging or poor connection
©
Repair hose or replace EVAP canister.
9
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR HOSE
Check disconnection or improper connection of hose connected to EVAP control system pressure sensor.
OK or NG
OK
©
GO TO 10.
NG
©
Repair it.
10
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
SEF495R
2. Check connectors for water.
Water should not exist.
OK or NG
OK
©
GO TO 11.
NG
©
Replace EVAP control system pressure sensor.
DTC P1448 EVAPORATIVE EMISSION (EVAP) CANISTER VENT CONTROL
VALVE (OPEN)
Diagnostic Procedure (Cont’d)
EC-580
11
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
I
Never apply force to the air hole protector of the sensor if equipped.
SEF799W
2. Remove hose from EVAP control system pressure sensor.
3. Turn ignition switch “ON”.
4. Use pump to apply vacuum and pressure to EVAP control system pressure sensor as shown in figure.
CAUTION:
I
Always calibrate the vacuum pump gauge when using it.
I
Do not apply below −20 kPa (−150 mmHg, −5.91 inHg) or over 20 kPa (150 mmHg, 5.91 inHg) of pressure.
5. Check input voltage between ECM terminal 84 and ground.
SEF342X
CAUTION:
I
Discard and EVAP control system pressure sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
OK or NG
OK
©
GO TO 12.
NG
©
Replace EVAP control system pressure sensor.
12
CHECK INTERMITTENT INCIDENT
Refer to “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-140.
©
INSPECTION END
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P1448 EVAPORATIVE EMISSION (EVAP) CANISTER VENT CONTROL
VALVE (OPEN)
Diagnostic Procedure (Cont’d)
EC-581
SEF018S
Component Description
NBEC0632
The fuel level sensor is mounted in the fuel level sensor unit. The
sensor detects a fuel level in the fuel tank and transmits a signal
to the ECM.
It consists of two parts, one is mechanical float and the other side
is variable resistor. Fuel level sensor output voltage changes
depending on the movement of the fuel mechanical float.
On Board Diagnostic Logic
NBEC0633
ECM receives two signals from the fuel level sensor.
One is fuel level sensor power supply circuit, and the other is fuel
level sensor ground circuit.
This diagnosis indicates the latter to detect open circuit malfunc-
tion. Malfunction is detected when a high voltage from the sensor
is sent to ECM.
Possible Cause
NBEC0634
I
Fuel level sensor circuit
(The fuel level sensor circuit is open or shorted.)
DTC Confirmation Procedure
NBEC0635
NOTE:
If “DTC Confirmation Procedure” has been previously conducted,
always turn ignition switch “OFF” and wait at least 10 seconds
before conducting the next test.
SEF195Y
WITH CONSULT-II
NBEC0635S01
1)
Turn ignition switch “ON”.
2)
Select “DATA MONITOR” mode with CONSULT-II.
3)
Wait at least 5 seconds.
4)
If 1st trip DTC is detected, go to “Diagnostic Procedure”,
EC-584.
WITH GST
NBEC0635S02
Follow the procedure “WITH CONSULT-II” above.
DTC P1464 FUEL LEVEL SENSOR CIRCUIT (GROUND SIGNAL)
Component Description
EC-582
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.