Infiniti EX35. Manual — part 472

DLK-102

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

COMBINATION METER DISPLAY FUNCTION

COMBINATION METER DISPLAY FUNCTION

Description

INFOID:0000000003728937

Displays each operation method guide and warning for system malfunction.

Component Function Check

INFOID:0000000003728938

1.

CHECK FUNCTION

Check the operation with (“LCD”) in the Active Test.

Is the inspection result normal?

YES

>> Meter display is OK.

NO

>> Refer to

DLK-102, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003728939

1.

CHECK COMBINATION METER

Refer to

MWI-101, "DTC Index"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Check combination meter. Refer to

MWI-4, "Work flow"

.

2.

CHECK INTERMITTENT INCIDENT

Refer to

GI-38, "Intermittent Incident"

.

>> INSPECTION END

Is each warning displayed on meter display?

BUZZER (COMBINATION METER)

DLK-103

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

BUZZER (COMBINATION METER)

Description

INFOID:0000000003728940

Performs operation method guide and warning with buzzer.

Component Function Check

INFOID:0000000003728941

1.

CHECK FUNCTION

1.

Check the operation with “INSIDE BUZZER” in the Active Test.

2.

Touch “TAKE OUT”, “KNOB”or “KEY”on screen.

Is the inspection result normal?

Yes

>> Warning buzzer into combination meter is OK.

No

>> Refer to

DLK-103, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003728942

1.

CHECK METER BUZZER CIRCUIT

Refer to

WCS-23, "Component Function Check"

.

Is the inspection result normal?

Yes

>> GO TO 2.

No

>> Repair or replace harness.

2.

CHECK INTERMITTENT INCIDENT

Refer to

GI-38, "Intermittent Incident"

.

>> INSPECTION END

DLK-104

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

KEY WARNING LAMP

KEY WARNING LAMP

Description

INFOID:0000000003728943

Performs operation method guide and warning together with buzzer.

Component Function Check

INFOID:0000000003728944

1.

CHECK FUNCTION

Check the operation with “INDICATOR” in “Active Test” mode with CONSULT-III.

Is the inspection result normal?

YES

>> Key warning lamp in combination meter is OK.

NO

>> Refer to

DLK-104, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003728945

1.

CHECK KEY WARNING LAMP

Refer to

MWI-38, "Diagnosis Description"

.

Is the inspection result normal?

Yes

>> GO TO 2.

No

>> Repair or replace harness.

2.

CHECK INTERMITTENT INCIDENT

Refer to

GI-38, "Intermittent Incident"

.

>> INSPECTION END

Test item

Condition

INDICATOR

RED ON

Key warning lamp (red) illuminates

RED IND

Key warning lamp (red) flashes

HAZARD FUNCTION

DLK-105

< COMPONENT DIAGNOSIS >

[INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

HAZARD FUNCTION

Description

INFOID:0000000003728946

Perform answer-back for each operation with number of blinks.

Component Function Check

INFOID:0000000003728947

1.

CHECK FUNCTION

Check hazard warning lamp (“FLASHER”) in Active Test.

Is the inspection result normal?

YES

>> Hazard warning lamp circuit is OK.

NO

>> Refer to

DLK-105, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003728948

1.

CHECK HAZARD SWITCH CIRCUIT

Refer to

EXL-104, "Wiring Diagram - TURN AND HAZARD WARNING LAMPS -"

(For xenon type) or

EXL-

275, "Wiring Diagram - TURN AND HAZARD WARNING LAMPS -"

(For halogen type)

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace harness.

2.

CHECK INTERMITTENT INCIDENT

Refer to

GI-38, "Intermittent Incident"

.

>> INSPECTION END