Infiniti EX35. Manual — part 472
DLK-102
< COMPONENT DIAGNOSIS >
[INTELLIGENT KEY SYSTEM]
COMBINATION METER DISPLAY FUNCTION
COMBINATION METER DISPLAY FUNCTION
Description
INFOID:0000000003728937
Displays each operation method guide and warning for system malfunction.
Component Function Check
INFOID:0000000003728938
1.
CHECK FUNCTION
Check the operation with (“LCD”) in the Active Test.
Is the inspection result normal?
YES
>> Meter display is OK.
NO
>> Refer to
DLK-102, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000003728939
1.
CHECK COMBINATION METER
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Check combination meter. Refer to
.
2.
CHECK INTERMITTENT INCIDENT
GI-38, "Intermittent Incident"
>> INSPECTION END
Is each warning displayed on meter display?
BUZZER (COMBINATION METER)
DLK-103
< COMPONENT DIAGNOSIS >
[INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BUZZER (COMBINATION METER)
Description
INFOID:0000000003728940
Performs operation method guide and warning with buzzer.
Component Function Check
INFOID:0000000003728941
1.
CHECK FUNCTION
1.
Check the operation with “INSIDE BUZZER” in the Active Test.
2.
Touch “TAKE OUT”, “KNOB”or “KEY”on screen.
Is the inspection result normal?
Yes
>> Warning buzzer into combination meter is OK.
No
>> Refer to
DLK-103, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000003728942
1.
CHECK METER BUZZER CIRCUIT
WCS-23, "Component Function Check"
.
Is the inspection result normal?
Yes
>> GO TO 2.
No
>> Repair or replace harness.
2.
CHECK INTERMITTENT INCIDENT
GI-38, "Intermittent Incident"
.
>> INSPECTION END
DLK-104
< COMPONENT DIAGNOSIS >
[INTELLIGENT KEY SYSTEM]
KEY WARNING LAMP
KEY WARNING LAMP
Description
INFOID:0000000003728943
Performs operation method guide and warning together with buzzer.
Component Function Check
INFOID:0000000003728944
1.
CHECK FUNCTION
Check the operation with “INDICATOR” in “Active Test” mode with CONSULT-III.
Is the inspection result normal?
YES
>> Key warning lamp in combination meter is OK.
NO
>> Refer to
DLK-104, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000003728945
1.
CHECK KEY WARNING LAMP
MWI-38, "Diagnosis Description"
.
Is the inspection result normal?
Yes
>> GO TO 2.
No
>> Repair or replace harness.
2.
CHECK INTERMITTENT INCIDENT
GI-38, "Intermittent Incident"
>> INSPECTION END
Test item
Condition
INDICATOR
RED ON
Key warning lamp (red) illuminates
RED IND
Key warning lamp (red) flashes
HAZARD FUNCTION
DLK-105
< COMPONENT DIAGNOSIS >
[INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
HAZARD FUNCTION
Description
INFOID:0000000003728946
Perform answer-back for each operation with number of blinks.
Component Function Check
INFOID:0000000003728947
1.
CHECK FUNCTION
Check hazard warning lamp (“FLASHER”) in Active Test.
Is the inspection result normal?
YES
>> Hazard warning lamp circuit is OK.
NO
>> Refer to
DLK-105, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000003728948
1.
CHECK HAZARD SWITCH CIRCUIT
EXL-104, "Wiring Diagram - TURN AND HAZARD WARNING LAMPS -"
275, "Wiring Diagram - TURN AND HAZARD WARNING LAMPS -"
(For halogen type)
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK INTERMITTENT INCIDENT
GI-38, "Intermittent Incident"
.
>> INSPECTION END
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.