Infiniti EX35. Manual — part 759
EXL-80
< COMPONENT DIAGNOSIS >
[XENON TYPE]
TURN SIGNAL LAMP CIRCUIT
YES
>> GO TO 3.
NO
>> Replace BCM.
3.
CHECK TURN SIGNAL LAMP OPEN CIRCUIT
1.
Turn the ignition switch OFF.
2.
Disconnect BCM connector.
3.
Check the continuity between the BCM harness connector and the front combination lamp or the rear
combination lamp harness connector.
Does continuity exist?
YES
>> GO TO 4.
NO
>> Repair the harnesses or connectors.
4.
CHECK TURN SIGNAL LAMP SHORT CIRCUIT
Check continuity between the BCM harness connector and the ground.
Does continuity exist?
YES
>> Repair the harnesses or connectors.
NO
>> GO TO 5.
5.
CHECK TURN SIGNAL LAMP GROUND OPEN CIRCUIT
Check the continuity between the BCM harness connector and the front combination lamp or the rear combi-
nation lamp and the ground.
Does continuity exist?
YES
>> Replace the front combination lamp or the rear combination lamp.
NO
>> Repair the harnesses or connectors.
BCM
Front combination lamp/
Rear combination lamp
Continuity
Connector
Terminal
Connector
Terminal
Front RH
M119
17
E28
6
Existed
Front LH
18
E58
6
Rear RH
M120
20
B261
1
Rear LH
25
B260
1
BCM
Ground
Continuity
Connector
Terminal
Front RH
M119
17
Not existed
Front LH
18
Rear RH
M120
20
Rear LH
25
Front combination lamp /
Rear combination lamp
Ground
Continuity
Connector
Terminal
Front RH
E28
4
Existed
Front LH
E58
4
Rear RH
B261
2
Rear LH
B260
2
OPTICAL SENSOR
EXL-81
< COMPONENT DIAGNOSIS >
[XENON TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
OPTICAL SENSOR
Description
INFOID:0000000003135347
Optical sensor converts the outside brightness (lux) to voltage and transmits the optical sensor signal to BCM.
Component Function Check
INFOID:0000000003135348
1.
CHECK OPTICAL SENSOR SIGNAL BY CONSULT-III
CONSULT-III DATA MONITOR
1.
Turn the ignition switch ON.
2.
Select "OPTICAL SENSOR" of BCM (HEADLAMP) data monitor item.
3.
Turn the lighting switch AUTO.
4.
With the optical sensor illuminating, check the monitor status.
*: Illuminates the optical sensor. The value may be less than the standard value if brightness is weak.
Is the item status normal?
YES
>> Optical sensor is normal.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000003135349
1.
CHECK OPTICAL SENSOR POWER SUPPLY INPUT
1.
Turn the ignition switch ON.
2.
Turn the lighting switch AUTO.
3.
Check the voltage between the optical sensor harness connector and the ground.
Is the measurement value normal?
YES
>> GO TO 2.
NO
>> GO TO 4.
2.
CHECK OPTICAL SENSOR GROUND INPUT
Check the voltage between the optical sensor harness connector and the ground.
Is the measurement value normal?
YES
>> GO TO 3.
NO
>> GO TO 6.
Monitor item
Condition
Voltage (Approx.)
OPTICAL SEN-
SOR
Optical sensor
When illuminat-
ing
3.1 V or more *
When shutting
off light
0.6 V or less
Terminals
Voltage
(Approx.)
(+)
(
−
)
Optical sensor
Ground
Connector
Terminal
M94
1
5 V
Terminals
Voltage
(Approx.)
(+)
(
−
)
Optical sensor
Ground
Connector
Terminal
M94
3
0 V
EXL-82
< COMPONENT DIAGNOSIS >
[XENON TYPE]
OPTICAL SENSOR
3.
CHECK OPTICAL SENSOR SIGNAL OUTPUT
With illuminating the optical sensor, check the voltage between the optical sensor harness connector and the
ground.
*: Illuminate the optical sensor. The value may be less than the standard if brightness is weak.
Is the measurement value normal?
YES
>> GO TO 7.
NO
>> Replace the optical sensor.
4.
CHECK OPTICAL SENSOR OPEN CIRCUIT
1.
Turn the ignition switch OFF.
2.
Disconnect the optical sensor connector and BCM connector.
3.
Check continuity between the optical sensor harness connector and the BCM harness connector.
Does continuity exist?
YES
>> GO TO 5.
NO
>> Repair the harnesses or connectors.
5.
CHECK OPTICAL SENSOR SHORT CIRCUIT
Check the continuity between the optical sensor harness connector and the ground.
Does continuity exist?
YES
>> Repair the harnesses or connectors.
NO
>> Replace BCM.
6.
CHECK OPTICAL SENSOR GROUND OPEN CIRCUIT
1.
Turn the ignition switch OFF.
2.
Disconnect the optical sensor connector and BCM connector.
3.
Check continuity between the optical sensor harness connector and the BCM harness connector.
Does continuity exist?
YES
>> Replace BCM.
NO
>> Repair the harnesses or connectors.
7.
CHECK OPTICAL SENSOR SIGNAL OPEN CIRCUIT
Terminals
Condition
Voltage
(Approx.)
(+)
(
−
)
Optical sensor
Ground
Optical sen-
sor
Connector
Terminal
M94
2
When illumi-
nating
3.1 V or
more *
When shut-
ting off light
0.6 V or less
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M94
1
M123
138
Existed
Optical sensor
Ground
Continuity
Connector
Terminal
M94
1
Not existed
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M94
3
M123
137
Existed
OPTICAL SENSOR
EXL-83
< COMPONENT DIAGNOSIS >
[XENON TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
1.
Turn the ignition switch OFF.
2.
Disconnect the optical sensor connector and BCM connector.
3.
Check continuity between the optical sensor harness connector and the BCM harness connector.
Does continuity exist?
YES
>> GO TO 8.
NO
>> Repair the harnesses or connectors.
8.
CHECK OPTICAL SENSOR SHORT CIRCUIT
Check the continuity between the optical sensor harness connector and the ground.
Does continuity exist?
YES
>> Repair the harnesses or connectors.
NO
>> Replace BCM.
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M94
2
M123
113
Existed
Optical sensor
Ground
Continuity
Connector
Terminal
M94
2
Not existed