Infiniti I30 (A33). Manual — part 366
Active Test
NHEL0214S0202
Test Item
Description
BATTERY SAVER
This test enables to check interior lamp, front step lamps, spot lamp, vanity mirror illuminations
and trunk room lamp operations.
When touch “ON” on CONSULT-II screen.
I
Interior lamp turns on when the switch is in ON.
(Smart entrance control unit supplies power to interior lamp.)
I
Front step lamps turn on when any doors are open.
(Smart entrance control unit supplies power to front step lamps.)
I
Spot lamp, vanity mirror illuminations, trunk room lamp turn on when the switch is in ON.
(Smart entrance control unit supplies power to Spot lamp, vanity mirror illuminations, trunk
room lamp.)
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
CONSULT-II Application Items (Cont’d)
EL-133
Trouble Diagnoses for Interior Lamp Timer
=NHEL0215
DIAGNOSTIC PROCEDURE 1
NHEL0215S01
SYMPTOM: Interior lamp timer does not operate.
1
CHECK IGNITION ON SIGNAL
With CONSULT-II
Check ignition switch ON signal (“IGN ON SW”) in “DATA MONITOR” mode with CONSULT-II.
SEL318W
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M144 terminal 27 (G) and ground.
SEL003Y
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
Trouble Diagnoses for Interior Lamp Timer
EL-134
2
CHECK FRONT LH DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check driver door switch signal (“DOOR SW-DR”) in “DATA MONITOR” mode with CONSULT-II.
SEL319WA
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M143 terminal 1 (SB) and ground.
SEL004Y
OK or NG
OK
©
GO TO 4.
NG
©
GO TO 3.
3
CHECK FRONT LH DOOR SWITCH
Check continuity between door switch connector B29 terminals 2 and 3.
SEL325WB
OK or NG
OK
©
Check the following.
I
Front LH door switch ground circuit and condition
I
Harness for open or short between smart entrance control unit and front LH door
switch
NG
©
Replace front LH door switch.
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
Trouble Diagnoses for Interior Lamp Timer (Cont’d)
EL-135
4
CHECK FRONT RH DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check driver door switch signal (“DOOR SW-AS”) in “DATA MONITOR” mode with CONSULT-II.
SEL153Y
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M143 terminal 2 (R/L) and ground.
SEL152Y
OK or NG
OK
©
GO TO 6.
NG
©
GO TO 5.
5
CHECK FRONT RH DOOR SWITCH
Check continuity between door switch connector B129 terminals 2 and 3.
SEL325WC
OK or NG
OK
©
Check the following.
I
Front RH door switch ground circuit and condition
I
Harness for open or short between smart entrance control unit and front RH door
switch
NG
©
Replace front RH door switch.