Infiniti G20 (P11). Manual — part 451
Refrigeration System
REFRIGERATION CYCLE
NCHA0121
Refrigerant Flow
NCHA0121S01
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser, the liquid tank,
through the evaporator, and back to the compressor. The refrigerant evaporation through the evaporator coil
is controlled by an externally equalized expansion valve, located inside the evaporator case.
Freeze Protection
NCHA0121S02
The compressor cycles go on and off to maintain the evaporator temperature within a specified range. When
the evaporator coil temperature falls below a specified point, the thermo control amplifier interrupts the com-
pressor operation. When the evaporator coil temperature rises above the specification, the thermo control
amplifier allows compressor operation.
Refrigerant System Protection
NCHA0121S03
Refrigerant Pressure Sensor
NCHA0121S0303
The refrigerant system is protected against excessively high or low pressures by the refrigerant pressure
sensor, located on the liquid tank. If the system pressure rises above, or falls below the specifications, the
refrigerant pressure sensor detects the pressure inside the refrigerant line and sends the voltage signal to the
ECM. ECM makes the A/C relay go OFF and stops the compressor when pressure on the high pressure side
detected by refrigerant pressure sensor is over about 2,746 kPa (28 kg/cm
2
, 398 psi) or below about 177 kPa
(1.8 kg/cm
2
, 26 psi).
Pressure Relief Valve
NCHA0121S0302
The refrigerant system is also protected by a pressure relief valve, located in the rear head of the compres-
sor. When the pressure of refrigerant in the system increases to an abnormal level [more than 3,727 kPa (38
kg/cm
2
, 540 psi)], the release port on the pressure relief valve automatically opens and releases refrigerant
into the atmosphere.
RHA347H
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
SC
EL
IDX
DESCRIPTION
MANUAL
Refrigeration System
HA-135
Component Layout
NCHA0122
RHA041H
DESCRIPTION
MANUAL
Component Layout
HA-136
Control Operation
NCHA0123
RHA184HA
FAN CONTROL SWITCH
NCHA0123S01
This switch turns the fan ON and OFF, and controls fan speed.
MODE SWITCHES
NCHA0123S02
These switches control the outlet air flow.
The indicator lamp will also light when the switch is depressed.
When DEF
or D/F
mode is selected, the push control unit sets the intake door to FRESH.
The compressor turns on when DEF
mode is selected.
TEMPERATURE CONTROL LEVER
NCHA0123S03
This lever allows you to adjust the temperature of the discharge air.
RECIRCULATION (REC) SWITCH
NCHA0123S04
OFF position: Outside air is drawn into the passenger compartment.
In VENT mode and hi coolant temperature [Over 105°C (221°F)] the intake door set to Recirculation position.
ON position: Interior air is recirculated inside the vehicle.
The indicator lamp will also light.
Recirculation is canceled when DEF
or D/F
mode is selected, and resumes when another mode is
chosen.
AIR CONDITIONER (A/C) SWITCH
NCHA0123S05
The air conditioner switch controls the A/C system. When the switch is depressed with the fan ON, the com-
pressor will turn ON. The indicator lamp will also light.
The air conditioner cooling function operates only when the engine is running.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
SC
EL
IDX
DESCRIPTION
MANUAL
Control Operation
HA-137
Discharge Air Flow
NCHA0124
RHA042H
DESCRIPTION
MANUAL
Discharge Air Flow