Volkswagen Golf / Golf GTI / Jetta. Manual — part 1033
01-44
Adaptation table
Adaptation
channel
Adaptation functions
03
Multi-function Indicator (MFA) fuel
consumption indicator (where
applicable), adaptation
Page
01-58
09
Odometer, adaptation
Page 01-
45
16
Distance impulse number (K-
number), reading/confirming
Page 01-50
30
Fuel gauge, checking/adapation
Page 01-53
Note:
After changing an adaption value or ending an
adaption channel the function "10 - Adaption"
must be performed to select another adaption
channel!
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-45
Odometer, adaptation
Notes:
Market and equipment appropriate coding of
instrument cluster must be performed before
adaptation of odometer reading
Page 01-29
.
The total distance travelled by the vehicle can
be read from the malfunctioning instrument
cluster or determined by the vehicle service
history.
The total distance travelled display of new
instrument cluster must not be more than 100
km (62 mi) before adaptation.
The total distance travelled to be transferred to
the new instrument cluster must exceed 100 km
(62 mi).
Adapting the total distance travelled is only
possible once and only in a positive (upwards)
direction.
Adaptation can be interrupted with the "C"
button of the VAG 1551
Correcting a false entry which has been
confirmed is not possible. The instrument
cluster must be exchanged for a new one.
Adaptation value must be entered in kilometers.
For US models, adaptation value must be
converted from miles to kilometers first (miles x
1.609 = kilometers).
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-46
Adaptation, example
The malfunctioning instrument cluster has an
odometer reading of 89627 km. This reading is
transferred to the new instrument cluster as
follows:
- Connect scan tool VAG 1551, select operating
mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"is
displayed.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press button -1- twice to select "Login" function
11.
- Press -Q- button to confirm input.
Rapid data transfer
Q
11 - Login procedure
Indicated on display:
- Press -Q- button to confirm input.
Login procedure
Q
Enter code number XXXXX
Indicated on display:
- Enter code number 13861.
Login procedure
Q
Enter code number 13861
Indicated on display:
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-47
"FAIL" appears in odometer if a false
code or secret number is entered 3
times.
In this case terminal 30 (battery)
must be disconnected and
reconnected again and the Login
procedure repeated using the correct
code number.
- Press -Q- button to confirm input.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -1- and -0- to select
"Adaptation" function 10.
Rapid data transfer
Q
10 - Adaptation
Indicated on display:
- Press -Q- button to confirm input.
Adaptation
Enter channel number XX
Indicated on display:
- Press buttons -0- and -9- to select
adaptation "channel 09".
- Press -Q- button to confirm input.
Channel 9 Adaptation 0
<-1 3->
- Indicated on display:
- Press
button to advance
program sequence.
Channel 9 Adaptation 0
Enter adaptation value XXXXX
Indicated on display:
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.