Volkswagen Golf / Golf GTI / Jetta. Manual — part 1034
01-48
- Enter adaptation value using VAG 1551 button
pad.
The last position of the kilometer reading must be
rounded off to the nearest 10 kms. Therefore, a
kilometer reading of 89627 produces an
adaptation value of:
0 8 9 6 3
X
Hundred thou.: 100000 ...
655350 km
X
Ten thousands: 10000 ...
90000 km
X
Thousands: 1000 ... 9000 km
X
Hundreds: 100 ... 900 km
X Tens: 10 ... 90 km
Units: round up to next ten
- After entering adaptation value using VAG 1551
button pad,
Channel 9 Adaptation 0
Q
Enter adaptation value 08963
Indicated on display (example only):
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Q
<-1 3->
Indicated on display:
The kilometer reading entered now appears in the
display of the instrument cluster. If the displayed
kilometer reading is not OK, e.g. false entry:
- Press -C- button and enter correct adaptation
value again.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-49
If the displayed kilometer reading in
instrument cluster is OK:
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Q
Store changed value?
Indicated on display:
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Changed value is stored
Indicated on display:
- End odometer adaptation by
pressing
button.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -6- to select
"End Output" function 06.
Rapid data transfer
Q
06 End Output
Indicated on display:
- Press -Q- button to confirm input.
Rapid data transfer
Help
Enter address word XX
Indicated on display:
The tester is now in basic function
again.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-50
Distance impulse number (K-number),
reading/confirming
Distance impulse number can only be
read/confirmed on VDO instrument clusters.
Distance impulse number for MMO instrument
clusters
Code control module,
Page 01-
29
.
Notes:
The distance impulse number is a constant
used to calculate the speed indication and
distance travelled.
The distance impulse number (K number)
cannot be changed using the "Adaptation"
function!
For instrument clusters with mile indicators, the
distance impulse number is shown in
kilometers. The trip impulse number for mile
values can be calculated as follows:Trip
impulse number for kilometer values x 1.609 =
trip impulse number for mile values.
Press the -C- button on the VAG 1551 to abort
the "Read distance impulse number" function.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-51
- Connect scan tool VAG 1551, select operating
mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"appears in
display.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -1- and -0- to select "Adaptation"
function 10.
Rapid data transfer
Q
10 - Adaptation
Indicated on display:
- Press -Q- button to confirm input.
Adaptation
Enter channel number XX
Indicated on display:
- Press buttons -1- and -6- to select adaptation
"channel 16".
- Press -Q- button to confirm input.
Channel 16 Adaptation 3538
<- 1 3 ->
Indicated on display (example only):
Read/confirm distance impulse number,
code