Volkswagen Golf / Golf GTI / Jetta. Manual — part 1047
2)
Distance impulse number is a constant used to
calculate speed indication and distance travelled.
Code for USA/CDN Golf/Jetta is always 2.
Distance impulse number can only be
read/confirmed using function 10, "Adaptation"
Page 01-125
.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-99
Instrument cluster 05.00 , coding
(function 07)
Using this function the instrument cluster can be
coded as follows:
Available equipment activation
Market versions
Service Intervals
Distance impulse number (K-number)
Note:
The code table lists only those combinations
applicable to Golf/Jetta through from 05.00 .
Initiating coding
- Connect scan tool VAG 1551, select operating
mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"is
displayed..
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -7- to select "Code control
module" function 07.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-100
Rapid data transfer
Q
07 - Code control module
Indicated on display:
- Press -Q- button to confirm input.
Code Control Module
Enter code number XXXXX
(0-32000)
Indicated on display:
Example:
Note:
Values shown below are examples
only!!
- Determine vehicle particulars and
input code number using coding
table
Page 01-102
.
02 Available equipment:
seatblet warning
active
2 Market version:
USA
3 Service Interval
2 Distance impulse
number
Code Control Module
Q
Enter code number 02232
(0-32000)
Indicated on display (example only):
- Press -Q- button to confirm input.
1J0919860D A4 COMBI INSTR VDO V04
Coding 02232 WSC 00000
Indicated on display (example only):
- Press
button.
Rapid data transfer
HELP
Select function XX
Indicated on display:
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-101
End function:
- Press buttons -0- and -6- to select "End Output"
function 06.
Rapid data transfer
Q
06 - End Output
Indicated on display:
- Press -Q- button to confirm input.
Rapid data transfer
Help
Enter address word XX
Indicated on display
The tester is now in basic function again.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст