Volkswagen Golf / Golf GTI / Jetta. Manual — part 394

01-319

Switch to measuring range:

Resistance measurement (200

/20 M

)

Test

step

V.A.G

1598

sockets

Item

tested

Test conditions

- Additional
operations

Specification Measures for

deviations from
specification

19

-

Wiring
for
sender 1
for brake
booster -
G201-

Ignition switched

off

Measuring

range set to 200

- Disconnect
connection from
sender 1 for brake
booster -G201-

- Disconnect multi-
pin connection T47
from ABS control
module (w/EDL) -
J104-

- Connect test box
V.A.G 1598/36

- Check wiring for
open circuit
between sender 1
for brake booster -
G201- multi-pin
connector and ABS
control module
(w/EDL) -J104-
multi-pin connector

Max. 1.5

Electrical Wiring

Diagrams,
Troubleshooting &
Component
Locations binder

- Check wiring
using wiring
diagram

Test step 19: Continued on next
page.

Electrical check of Mark 60

01-320

Continuation of test step 19

Test

step

V.A.G

1598

sockets

Item

tested

Test

conditions

- Additional
operations

Specification Measures for

deviations from
specification

- Set measuring
range to 20 M

- Remove fuse
S9

- Check wiring
for short circuit
to positive or
Ground

Electrical Wiring

Diagrams,
Troubleshooting &
Component Locations
binder

- Check wiring using
wiring diagram

Electrical check of Mark 60

01-321

Switch to measuring range:

Resistance measurement (200

/20 M

)

Test

step

V.A.G

1598

sockets

Item

tested

Test conditions

- Additional
operations

Specification Measures for

deviations from
specification

20

11 or 15 Data

bus
wiring

Ignition

switched off

Measuring set

range to 200

- Disconnect multi-
pin connection
from a control
module which is
connected via data
bus wiring:

- Connect test box
V.A.G 1598/36

- Check data bus
wiring for open
circuit

Max. 1.5

Electrical Wiring

Diagrams,
Troubleshooting &
Component
Locations binder

- Check wiring
using wiring
diagram

Test step 20: Continued on next
page

Electrical check of Mark 60

01-322

Continuation of test step 20

Test

step

V.A.G

1598

sockets

Item

tested

Test

conditions

- Additional
operations

Specification Measures for

deviations from
specification

- Set measuring
range to 20 M

- Remove fuse
S9

- Check wiring
for short circuit
to positive or
Ground

Electrical Wiring

Diagrams,
Troubleshooting &
Component Locations
binder

- Check wiring using
wiring diagram

Electrical check of Mark 60

Была ли эта страница вам полезна?