Volkswagen Golf / Golf GTI / Jetta. Manual — part 394
01-319
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item
tested
Test conditions
- Additional
operations
Specification Measures for
deviations from
specification
19
-
Wiring
for
sender 1
for brake
booster -
G201-
Ignition switched
off
Measuring
range set to 200
- Disconnect
connection from
sender 1 for brake
booster -G201-
- Disconnect multi-
pin connection T47
from ABS control
module (w/EDL) -
J104-
- Connect test box
V.A.G 1598/36
- Check wiring for
open circuit
between sender 1
for brake booster -
G201- multi-pin
connector and ABS
control module
(w/EDL) -J104-
multi-pin connector
Max. 1.5
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Test step 19: Continued on next
page.
Electrical check of Mark 60
01-320
Continuation of test step 19
Test
step
V.A.G
1598
sockets
Item
tested
Test
conditions
- Additional
operations
Specification Measures for
deviations from
specification
- Set measuring
range to 20 M
- Remove fuse
S9
- Check wiring
for short circuit
to positive or
Ground
Electrical Wiring
Diagrams,
Troubleshooting &
Component Locations
binder
- Check wiring using
wiring diagram
Electrical check of Mark 60
01-321
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item
tested
Test conditions
- Additional
operations
Specification Measures for
deviations from
specification
20
11 or 15 Data
bus
wiring
Ignition
switched off
Measuring set
range to 200
- Disconnect multi-
pin connection
from a control
module which is
connected via data
bus wiring:
- Connect test box
V.A.G 1598/36
- Check data bus
wiring for open
circuit
Max. 1.5
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Test step 20: Continued on next
page
Electrical check of Mark 60
01-322
Continuation of test step 20
Test
step
V.A.G
1598
sockets
Item
tested
Test
conditions
- Additional
operations
Specification Measures for
deviations from
specification
- Set measuring
range to 20 M
- Remove fuse
S9
- Check wiring
for short circuit
to positive or
Ground
Electrical Wiring
Diagrams,
Troubleshooting &
Component Locations
binder
- Check wiring using
wiring diagram
Electrical check of Mark 60