Volkswagen Golf / Golf GTI / Jetta. Manual — part 393
01-315
Continuation of test step 17a
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item
tested
Test conditions
- Additional
operations
Specification Measures for
deviations from
specification
17a
-
Wiring
for
steering
angle
sensor -
G85-
Measuring
range set to
200
Ignition
switched off
- Connect test box
V.A.G 1598/36
- Check wiring for
open circuit
between steering
angle sensor -G85-
and ABS control
module (w/EDL) -
J104- multi-pin
connector
Max. 1.5
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Test step 17a: On next page.
Electrical check of Mark 60
01-316
Continuation of test step 17a
Test
step
V.A.G
1598
sockets
Item
tested
Test
conditions
- Additional
operations
Specification Measures for
deviations from
specification
17a
Wiring for
steering
angle
sensor -
G85-
- Set measuring
range to 20 M
- Remove fuse
S9
- Check wiring
for short circuit
to positive or
Ground
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Electrical check of Mark 60
01-317
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item tested
Test
conditions
- Additional
operations
Specification Measures for
deviations from
specification
18
-
Wiring for
sensor for
transverse
acceleration -
G200- and
sender for
rotation rate -
G202-
Ignition
switched off
Measuring
range set to
200
- Connect test
box
V.A.G1598/36
- Check wiring for
open circuit
between multi-pin
connector of
sensor for
transverse
acceleration -
G200-, sender for
rotation rate -
G202- and multi-
pin connector of
ABS control
module (w/EDL) -
J104-:
Max. 1.5
Electrical
Wiring Diagrams,
Troubleshooting
& Component
Locations binder
- Check wiring
using wiring
diagram
Test step 18: Continued on next
page.
Electrical check of Mark 60
01-318
Continuation of test step 18
Test
step
V.A.G
1598
sockets
Item
tested
Test
conditions
- Additional
operations
Specification Measures for
deviations from
specification
- Set measuring
range to 20 M
- Remove fuse
S9
- Check wiring
for short circuit
to positive or
Ground
Electrical Wiring
Diagrams,
Troubleshooting &
Component Locations
binder
- Check wiring using
wiring diagram
Electrical check of Mark 60