Volkswagen Golf / Golf GTI / Jetta. Manual — part 393

01-315

Continuation of test step 17a

Switch to measuring range:

Resistance measurement (200

/20 M

)

Test

step

V.A.G

1598

sockets

Item

tested

Test conditions

- Additional
operations

Specification Measures for

deviations from
specification

17a

-

Wiring
for
steering
angle
sensor -
G85-

Measuring

range set to
200

Ignition

switched off

- Connect test box
V.A.G 1598/36

- Check wiring for
open circuit
between steering
angle sensor -G85-
and ABS control
module (w/EDL) -
J104- multi-pin
connector

Max. 1.5

Electrical Wiring

Diagrams,
Troubleshooting &
Component
Locations binder

- Check wiring
using wiring
diagram

Test step 17a: On next page.

Electrical check of Mark 60

01-316

Continuation of test step 17a

Test

step

V.A.G

1598

sockets

Item

tested

Test

conditions

- Additional
operations

Specification Measures for

deviations from
specification

17a

Wiring for

steering

angle

sensor -

G85-

- Set measuring
range to 20 M

- Remove fuse
S9

- Check wiring
for short circuit
to positive or
Ground

Electrical Wiring

Diagrams,
Troubleshooting &
Component
Locations binder

- Check wiring
using wiring
diagram

Electrical check of Mark 60

01-317

Switch to measuring range:

Resistance measurement (200

/20 M

)

Test

step

V.A.G

1598

sockets

Item tested

Test

conditions

- Additional
operations

Specification Measures for

deviations from
specification

18

-

Wiring for
sensor for
transverse
acceleration -
G200- and
sender for
rotation rate -
G202-

Ignition

switched off

Measuring

range set to
200

- Connect test
box
V.A.G1598/36

- Check wiring for
open circuit
between multi-pin
connector of
sensor for
transverse
acceleration -
G200-, sender for
rotation rate -
G202- and multi-
pin connector of
ABS control
module (w/EDL) -
J104-:

Max. 1.5

Electrical

Wiring Diagrams,
Troubleshooting
& Component
Locations binder

- Check wiring
using wiring
diagram

Test step 18: Continued on next
page.

Electrical check of Mark 60

01-318

Continuation of test step 18

Test

step

V.A.G

1598

sockets

Item

tested

Test

conditions

- Additional
operations

Specification Measures for

deviations from
specification

- Set measuring
range to 20 M

- Remove fuse
S9

- Check wiring
for short circuit
to positive or
Ground

Electrical Wiring

Diagrams,
Troubleshooting &
Component Locations
binder

- Check wiring using
wiring diagram

Electrical check of Mark 60