Volkswagen Golf / Golf GTI / Jetta. Manual — part 1049
01-105
Notes:
Interpreting display groups and evaluating
measured values in individual display fields
tables beginning
Page 01-106
.
With the printer switched on, the information on
the display is printed out.
To easily change between display groups,
proceed as follows:
Display
group
VAG 1551
VAG 1552
Higher
Press button
3
Press
button
Lower
Press button
1
Press
button
Skip
Press button
C
Press button
C
- Displayed after pressing C button.
Read Measuring Value Block HELP
Enter display group number XXX
Indicated on display:
Notes:
- Enter alternate display group number as needed
tables beginning
Page 01-106
.
Display fields always show actual values
transmitted from senders and sensors.
However, instrument cluster display values can
differ from those in the display fields due to
internal filtering.
Other display groups are possible, but are not
required for On Board Diagnostic program!
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-106
Display groups, interpreting
Display group 001
Read Measuring
Value Block 1
Indicated on
display
xxx
xxx
xxx xxx
1
2
3
4
Display
fields
Designation
Evaluating
display fields
Time
Clock time in hours
and minutes
Page 01-107
Oil pressure switch
0.9 bar
Oilp2<min
Oilp2 OK.
Engine speed (RPM)
Engine speed in rpm
Speed
Speed in km/h
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-107
Evaluating display group 001
Display
field
Description
Display
Corrective actions
1
Speed
Speed in km/h
- Visually check wire routing
- Check harness connectors of the
appropriate electrical circuit for proper
and secure seating and simultaneously
observe display
- If the display content does not change
during operation, repair malfunction or
replace the relevant component
- Erase DTC memory
- Perform functional check
- Check DTC memory again
2
Engine speed
(RPM)
Engine speed
in rpm
3
Oil pressure
switch 0.9 bar
Oilp2<min
Oilp2 OK.
4
Time
Clock time in
hours and
minutes
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-108
Display group 002
Read Measuring
Value Block 2
Indicated on
display
xxx
xxx
xxx
xxx
1
2
3
4
Display fields
Designation
Evaluating
display fields
Ambient
temperature
1)
Ambient
temperature in
C
Page 01-109
value of sender for
fuel gauge -G-
Resistance in
Fuel level
Fuel level in liters
Distance travelled (odometer)
Distance in km
1)
For instrument clusters with Multi Function Indicator (MFI) or Climatronic
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005