Volkswagen Golf / Golf GTI / Golf Variant. Manual — part 160
DTC /
Descrip‐
tion
Monitor
Strategy
Descrip‐
tion
Malfunction Crite‐
ria and Threshold
Value
Secondary Parame‐
ters with Enable
Conditions
Monitor‐
ing Time
Length
MIL Il‐
lum.
Component Diag‐
nostic Procedure
P0659
Actuator
Supply
Voltage
"A" Cir‐
cuit High
Supply
Voltage
Relay En‐
gine
Compo‐
nents
Short To
Battery
Voltage
• Output current
driver stage in‐
ternal value
• Or
• Actuator tem‐
perature (hard‐
ware values) >
175 – 195° C
• Relay comman‐
ded on
P0686
ECM/
PCM
Power
Relay
Control
Circuit
Low
Main Re‐
lay Ra‐
tionality
Check
During
Engine
Off
• Sensed circuit
voltage > 6.00
V
• Main relay com‐
manded on
• For time >= 0.3 s
• 0.1 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Mo‐
tronic Engine
Control Module
Power Supply
Relay - J271- .
Refer to
P0687
ECM/
PCM
Power
Relay
Control
Circuit
High
Main Re‐
lay Ra‐
tionality
Check
During
Engine
Running
• Sensed circuit
voltage < 5.00
V
• Main relay com‐
manded on
• For time >= 0.1 s
• 0.1 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Mo‐
tronic Engine
Control Module
Power Supply
Relay - J271- .
Refer to
Main Re‐
lay Short
To Bat‐
tery Plus
• Main relay driv‐
er temperature
> 175 – 195° C
• Or
• Main relay out‐
put current
(hardware val‐
ues) driver
stage internal
value
• Main relay com‐
manded on
• For time >= 0.4 s
• 0.2 s
• Con‐
tinu‐
ous
P0698
Sensor
Refer‐
ence
Voltage
"C" Cir‐
cuit Low
ECM: 5V
Supply
Voltage
Out Of
Range
Low
• Analog output
3 supply volt‐
age < 4.62 V
• 0.2 s
• Con‐
tinu‐
ous
• 2
DCY
– If a related sen‐
sor voltage code
is also set, refer
to that sensor for
diagnosis first. If
no other related
codes set, re‐
place the Engine
Control Module -
J623- . Refer to
appropriate re‐
pair manual.
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
3. Diagnosis and Testing
313
DTC /
Descrip‐
tion
Monitor
Strategy
Descrip‐
tion
Malfunction Crite‐
ria and Threshold
Value
Secondary Parame‐
ters with Enable
Conditions
Monitor‐
ing Time
Length
MIL Il‐
lum.
Component Diag‐
nostic Procedure
P0699
Sensor
Refer‐
ence
Voltage
"C" Cir‐
cuit High
ECM: 5V
Supply
Voltage
Out Of
Range
High
• Analog output
3 supply volt‐
age > 5.43 V
• 0.2 s
• Con‐
tinu‐
ous
• 2
DCY
– If a related sen‐
sor voltage code
is also set, refer
to that sensor for
diagnosis first. If
no other related
codes set, re‐
place the Engine
Control Module -
J623- . Refer to
appropriate re‐
pair manual.
P11A1
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 1
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 1 Exhaust
Camshaft Ad‐
juster A - N580- .
Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11A2
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 1
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 1 Exhaust
Camshaft Ad‐
juster A - N580- .
Refer to
P11A3
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 1
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 1 Exhaust
Camshaft B -
N581- . Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11A4
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 1
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 1 Exhaust
Camshaft B -
N581- . Refer to
P11A5
Cam
Shift Ac‐
tuator
"A" Cyl‐
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 2 Exhaust
Camshaft Ad‐
juster A - N588- .
Refer to
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
314
Rep. Gr. ST - Generic Scan Tool
DTC /
Descrip‐
tion
Monitor
Strategy
Descrip‐
tion
Malfunction Crite‐
ria and Threshold
Value
Secondary Parame‐
ters with Enable
Conditions
Monitor‐
ing Time
Length
MIL Il‐
lum.
Component Diag‐
nostic Procedure
inder 2
Circuit/
Open
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11A6
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 2
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 2 Exhaust
Camshaft Ad‐
juster A - N588- .
Refer to
P11A7
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 2
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 2 Exhaust
Camshaft B -
N589- . Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11A8
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 2
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 2 Exhaust
Camshaft B -
N589- . Refer to
P11A9
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 3
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 3 Exhaust
Camshaft Ad‐
juster A - N596- .
Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
3. Diagnosis and Testing
315
DTC /
Descrip‐
tion
Monitor
Strategy
Descrip‐
tion
Malfunction Crite‐
ria and Threshold
Value
Secondary Parame‐
ters with Enable
Conditions
Monitor‐
ing Time
Length
MIL Il‐
lum.
Component Diag‐
nostic Procedure
P11AA
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 3
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 3 Exhaust
Camshaft Ad‐
juster A - N596- .
Refer to
P11AB
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 3
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 3 Exhaust
Camshaft B -
N597- . Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11AC
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 3
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 3 Exhaust
Camshaft B -
N597- . Refer to
P11AD
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 4
Circuit/
Open
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 4 Exhaust
Camshaft Ad‐
juster A - N604- .
Refer to
Variable
Valve Lift
(VVL)
open cir‐
cuit
• Output voltage,
lower range <
1.92 – 2.21 V
• Output voltage,
upper range >
2.85 – 3.25 V
• 2
DCY
P11AE
Cam
Shift Ac‐
tuator
"A" Cyl‐
inder 4
Range/
Per‐
for‐
mance
Variable
Valve Lift
(VVL) ra‐
tionality
check low
• Actuator feed‐
back signal
voltage perma‐
nently low [-]
• Modeled oil tem‐
perature < 20° C
• 6.0 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 4 Exhaust
Camshaft Ad‐
juster A - N604- .
Refer to
P11AF
Cam
Shift Ac‐
tuator
"B" Cyl‐
inder 4
Variable
Valve Lift
(VVL)
short to
ground
• Output voltage
< 1.92 – 2.21 V
(hardware val‐
ues)
• Actuator com‐
manded off
• 0.5 s
• Con‐
tinu‐
ous
• 2
DCY
– Check the Cylin‐
der 4 Exhaust
Camshaft B -
N605- . Refer to
GTI 2014 ➤