Volkswagen Golf / Golf GTI / Golf Variant. Manual — part 194
DQ-250 6F 02E
DTC
Fault
Code De‐
scription
Monitor Strat‐
egy Descrip‐
tion
Malfunction
Criteria
Threshold
Value
Secondary Pa‐
rameters with
Enable Condi‐
tions
Monitor‐
ing Time
Length
Frequen‐
cy of
checks,
MIL Illum
• plausibility
check of se‐
lector lever
• selector
lever posi‐
tion is not
equal to
negation of
the inverse
selector
lever posi‐
tion
OR
• selector
lever posi‐
tion equals
initializa‐
tion value
OR
• selector
lever posi‐
tion equals
error value
OR
• selector
lever posi‐
tion is
equal to
negation of
the inverse
selector
lever posi‐
tion but no
valid posi‐
tion
• selector
lever posi‐
tion = Posi‐
tion 1 or
Position 2
or Position
3 or Posi‐
tion 4 or
Position L
• no bus off er‐
ror
• no error fail‐
ure of all
CAN mes‐
sages
• no failure of
selector lev‐
er CAN mes‐
sages
• time after
Reset > 1100
ms
• terminal 15
voltage > 9 V
for more than
1100 ms
• 1000
ms
• question
and answer
diagnosis
• failure of
question
and an‐
swer diag‐
nosis
• 1500
ms
P0919 Gear
Shift Po‐
sition
Control
Error
• evaluation
the error
signal of se‐
lector lever
CAN mes‐
sage
• error flag
of not de‐
terminable
selector
lever posi‐
tion is set
• no failure of
selector lev‐
er CAN mes‐
sages
• terminal 15
voltage > 4 V
for more than
500 ms
• battery volt‐
age > 9 V for
more than
500 ms
• engine
speed > 500
rpm
• 20 ms • 2 driv‐
ing cy‐
cles
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
3. Diagnosis and Testing
449
DQ-250 6F 02E
DTC
Fault
Code De‐
scription
Monitor Strat‐
egy Descrip‐
tion
Malfunction
Criteria
Threshold
Value
Secondary Pa‐
rameters with
Enable Condi‐
tions
Monitor‐
ing Time
Length
Frequen‐
cy of
checks,
MIL Illum
• validity
check of se‐
lector lever
position
• if the se‐
lector lever
position is
equal to
negation of
the inverse
selector
lever posi‐
tion but is
not valid
(position =
L, P4, P3,
P2, or P1)
AND
• is not in er‐
ror state
(position !=
error)
AND
• initializa‐
tion value
with the in‐
itialization
flag not set
then incre‐
ment an
event
counter
• no failure of
selector lev‐
er CAN mes‐
sages
• terminal 15
voltage > 4 V
for more than
500 ms
• error detec‐
tion of the
question
and answer
diagnosis
• if the an‐
swer of the
diagnosis
is wrong
an event
counter is
incremen‐
ted
• no failure of
selector lev‐
er CAN mes‐
sages
• terminal 15
voltage > 4 V
for more than
500 ms
• 100
ms
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
450
Rep. Gr. ST - Generic Scan Tool
DQ-250 6F 02E
DTC
Fault
Code De‐
scription
Monitor Strat‐
egy Descrip‐
tion
Malfunction
Criteria
Threshold
Value
Secondary Pa‐
rameters with
Enable Condi‐
tions
Monitor‐
ing Time
Length
Frequen‐
cy of
checks,
MIL Illum
• plausibility
check of se‐
lector lever
position
• if the se‐
lector lever
position is
not equal
to negation
of the in‐
verse se‐
lector lever
position
OR
• selector
lever posi‐
tion equals
initializa‐
tion value
but the ini‐
tialization
flag is not
set
OR
• selector
lever posi‐
tion equals
error value
then incre‐
ment an
event
counter
• no failure of
selector lev‐
er CAN mes‐
sages
• terminal 15
voltage > 4 V
for more than
500 ms
• battery volt‐
age > 9 V for
more than
500 ms
• engine
speed > 500
rpm
• 400
ms
P0929 Gear
Shift Lock
Solenoid/
Actuator
Control
Circuit
"A"
Range/
Perform‐
ance
• validity
check of
shiftlock po‐
sition signal
• if the shift‐
lock posi‐
tion signal
is not valid
(position !=
error, de‐
active, ac‐
tive or init)
increment
an event
counter
• no failure of
selector lev‐
er CAN mes‐
sages
• terminal 15
voltage > 4 V
for more than
500 ms
• 20 ms • 2 driv‐
ing cy‐
cles
P2711 Unexpec‐
ted Me‐
chanical
Gear Dis‐
engage‐
ment
• unable to
engage a
gear on
shaft 1
• the num‐
ber of suc‐
cessive
engage‐
ments of
the same
gear on
shaft 1 ex‐
ceeds a
maximum
value
• coun‐
ter>=6
• battery volt‐
age > 9 V for
more than
500 ms
• engine
speed > 600
rpm for more
than 500 ms
• 0 ms • 2 driv‐
ing cy‐
cles
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
3. Diagnosis and Testing
451
DQ-250 6F 02E
DTC
Fault
Code De‐
scription
Monitor Strat‐
egy Descrip‐
tion
Malfunction
Criteria
Threshold
Value
Secondary Pa‐
rameters with
Enable Condi‐
tions
Monitor‐
ing Time
Length
Frequen‐
cy of
checks,
MIL Illum
• unable to
engage a
gear on
shaft 2
• the num‐
ber of suc‐
cessive
engage‐
ments of
the same
gear on
shaft 2 ex‐
ceeds a
maximum
value
• detect dis‐
engage‐
ment of
gears on
shaft 1 with‐
out control
• In spite of
a constant
desired
gear dis‐
engage‐
ment
counter
exceeds a
maximum
value
• counter >3 • battery volt‐
age > 9 V for
more than
500 ms
• engine
speed > 600
rpm for more
than 500 ms
• output speed
>= 12 rpm
• detect dis‐
engage‐
ment of
gears on
shaft 2 with‐
out control
• In spite of
a constant
desired
gear dis‐
engage‐
ment
counter
exceeds a
maximum
value
GTI 2014 ➤
Generic Scan Tool - Edition 04.2015
452
Rep. Gr. ST - Generic Scan Tool