Nissan Frontier D40. Instruction — part 386
P0448 EVAP CANISTER VENT CONTROL VALVE
EC-235
< COMPONENT DIAGNOSIS >
[QR25DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
4.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.0 kg (4.4 lb).
OK or NG
OK
>> GO TO 6.
NG
>> GO TO 5.
5.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
6.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1.
Disconnect EVAP control system pressure sensor (2) harness
connector.
- EVAP canister vent control valve (1)
- Drain filter (3)
- EVAP canister (4)
-
: Vehicle front
2.
Check that water is not inside connectors.
OK or NG
OK
>> GO TO 7.
NG
>> Replace EVAP control system pressure sensor.
7.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-247, "Component Inspection"
OK or NG
OK
>> GO TO 8.
NG
>> Replace EVAP control system pressure sensor.
8.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000005273232
EVAP CANISTER VENT CONTROL VALVE
With CONSULT-III
1.
Remove EVAP canister vent control valve from EVAP canister.
2.
Check portion B of EVAP canister vent control valve for being
rusted.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
3.
Reconnect harness connectors disconnected.
4.
Turn ignition switch ON.
ALBIA0514ZZ
PBIB1033E
EC-236
< COMPONENT DIAGNOSIS >
[QR25DE]
P0448 EVAP CANISTER VENT CONTROL VALVE
5.
Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
6.
Check air passage continuity and operation delay time.
Operation takes less than 1 second.
Make sure new O-ring is installed properly.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
7.
Clean the air passage (Portion A to B) of EVAP canister vent control valve using an air blower.
8.
Perform step 6 again.
Without CONSULT-III
1.
Remove EVAP canister vent control valve from EVAP canister.
2.
Check portion B of EVAP canister vent control valve for being
rusted.
3.
Check air passage continuity and operation delay time under the
following conditions.
Operation takes less than 1 second.
Make sure new O-ring is installed properly.
If NG, replace EVAP canister vent control valve.
If OK, go to next step.
4.
Clean the air passage (Portion A to B) of EVAP canister vent control valve using an air blower.
5.
Perform step 3 again.
Condition VENT CONTROL/V
Air passage continuity between A and B
ON
No
OFF
Yes
PBIB1033E
Condition
Air passage continuity between A and B
12V direct current supply between
terminals 1 and 2
No
OFF
Yes
PBIB1034E
P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-237
< COMPONENT DIAGNOSIS >
[QR25DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
Component Description
INFOID:0000000005273233
The EVAP control system pressure sensor (2) detects pressure in
the purge line. The sensor output voltage to the ECM increases as
pressure increases.
• EVAP canister vent control valve (1)
• Drain filter (3)
• EVAP canister (4)
•
: Vehicle front
On Board Diagnosis Logic
INFOID:0000000005273234
NOTE:
If DTC P0451 is displayed with DTC P0643, first perform the trouble diagnosis for DTC P0643. Refer to
.
DTC Confirmation Procedure
INFOID:0000000005273235
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-III
1.
Turn ignition switch OFF and wait at least 10 seconds.
2.
Start engine and wait at least 40 seconds.
3.
Check 1st trip DTC.
4.
If 1st trip DTC is detected, go to
NOTE:
Do not depress accelerator pedal even slightly.
WITH GST
Follow the procedure “WITH CONSULT-III” above.
Diagnosis Procedure
INFOID:0000000005273236
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
ALBIA0514ZZ
PBIB3370E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0451
0451
EVAP control system pressure
sensor performance
ECM detects a sloshing signal from the
EVAP control system pressure sensor
• Harness or connectors
• EVAP control system pressure sensor
EC-238
< COMPONENT DIAGNOSIS >
[QR25DE]
P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR
2.
Loosen and retighten two ground screws on the body. Refer to
.
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace ground connections.
2.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
1.
Disconnect EVAP control system pressure sensor (2) harness
connector.
- EVAP canister vent control valve (1)
- Drain filter (3)
- EVAP canister (4)
: Vehicle front
2.
Check that water is not inside connector.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace harness connector.
3.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-238, "Component Inspection"
OK or NG
OK
>> GO TO 4.
NG
>> Replace EVAP control system pressure sensor.
4.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000005273237
EVAP CONTROL SYSTEM PRESSURE SENSOR
1.
Remove EVAP control system pressure sensor with its harness connector.
Always replace O-ring with a new one.
2.
Install a vacuum pump to EVAP control system pressure sensor.
3.
Turn ignition switch ON and check output voltage between ECM
terminal 32 and ground under the following conditions.
CAUTION:
• Always calibrate the vacuum pump gauge when using it.
• Never apply below -93.3 kPa (-0.952 kg/cm
2
, -13.53 psi) or
pressure over 101.3 kPa (1.033 kg/cm
2
, 14.69 psi).
BBIA0614E
ALBIA0514ZZ
Applied vacuum kPa
(kg/cm
2
, psi)
Voltage (V)
Not applied
1.8 - 4.8
-26.7 (-0.272, -3.87)
2.1 to 2.5V lower than above value
PBIB1200E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.