Nissan Tiida C11. Instruction — part 618
EC-1122
< COMPONENT DIAGNOSIS >
[K9K]
P0090 FUEL PUMP
P0090 FUEL PUMP
DTC Logic
INFOID:0000000001162566
DTC DETECTION LOGIC
NOTE:
• Conditions for applying the diagnostic procedure to the stored DTCs:
The DTC becomes present after the engine is started.
• If the DTC is present:
- Malfunction indicator (Red) lights up.
Diagnosis Procedure
INFOID:0000000001162567
1.
CHECK HIGH PRESSURE SUPPLY PUMP (PRESSURE CONTROL VALVE) POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect high pressure supply pump (pressure control valve) harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between high pressure supply pump (pressure control valve) harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• IPDM E/R
• Harness for open or short between IPDM E/R and high pressure supply pump (pressure control valve)
• Harness for open or short between ECM and high pressure supply pump (pressure control valve)
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK HIGH PRESSURE SUPPLY PUMP (PRESSURE CONTROL VALVE) OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between high pressure supply pump (pressure control valve) harness connector and
ECM harness connector.
4.
Also check harness for short to ground and short to power.
DTC No.
Trouble diagnosis name
Possible cause
P0090
HIGH PRESSURE SUPPLY PUMP (PRESSURE CONTROL VALVE)
CIRCUIT
• CO: Open circuit
• CO.0: Short circuit to ground
• CC.1: Short circuit to +12V
• 1.DEF: Parameter at maximum level
• Harness or connectors
[High pressure supply pump (pressure
control valve) circuit is open or shorted.]
• High pressure supply pump (pressure
control valve)
High pressure supply pump
(Pressure control valve)
Ground
Voltage
Connector
Terminal
F53
3
Ground
Battery voltage
High pressure supply pump
(Pressure control valve)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F53
4
F11
49
Existed
P0090 FUEL PUMP
EC-1123
< COMPONENT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
HIGH PRESSURE SUPPLY PUMP (PRESSURE CONTROL VALVE) CHECK
EC-1123, "Component Inspection"
.
Is the inspection result normal?
Yes
>> GO TO 5.
No
>> Replace high pressure supply pump.
5.
CHECK INTERMITTENT INCIDENT
GI-55, "Intermittent Incident"
.
>> INSPECTIO END
Component Inspection
INFOID:0000000001162568
1.
CHECK HIGH PRESSURE SUPPLY PUMP (PRESSURE CONTROL VALVE)
1.
Turn ignition switch OFF.
2.
Disconnect high pressure supply pump (pressure control valve) harness connector.
3.
Check resistance between high pressure supply pump (pressure control valve) terminals as follows.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace high pressure supply pump.
Terminals
Resistance
3 and 4
1.5 - 15
Ω
EC-1124
< COMPONENT DIAGNOSIS >
[K9K]
P0100 MAF SENSOR
P0100 MAF SENSOR
Description
INFOID:0000000001162569
The mass air flow sensor is placed in the stream of intake air.
• Intake air temperature sensor (1)
DTC Logic
INFOID:0000000001162570
DTC DETECTION LOGIC
NOTE:
• If DTC P0100 is displayed with DTC P0641, first perform trouble diagnosis for DTC P0641. Refer to
.
• Conditions for applying the diagnostic procedure to the stored DTCs:
The DTC is declared present after the ignition has been switched on.
Diagnosis Procedure
INFOID:0000000001162571
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Check ground connection E15. Refer to Ground inspection in
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT-I
1.
Turn ignition switch OFF.
2.
Disconnect mass air flow sensor harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between mass air flow sensor harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
MBIB1523E
DTC No.
Trouble diagnosis name
Possible cause
P0100
MASS AIR FLOW SENSOR CIRCUIT
• CC.0: Short circuit to ground
• CO.1: Open circuit or short circuit to +12V
• Harness or connectors
(Mass air flow sensor circuit is open or
shorted.)
• Mass air flow sensor
Mass air flow sensor
Ground
Voltage
Connector
Terminal
F31
4
Ground
Battery voltage
P0100 MAF SENSOR
EC-1125
< COMPONENT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
• Harness for open or short between IPDM E/R and mass air flow sensor
• Harness for open or short between ECM and mass air flow sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT-II
Check the voltage between mass air flow sensor harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK MASS AIR FLOW SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connectors.
3.
Check the continuity between mass air flow sensor harness connector and ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
6.
CHECK MASS AIR FLOW SENSOR NPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between mass air flow sensor harness connector and ECM harness connector.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
7.
CHECK MASS AIR FLOW SENSOR
EC-1125, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Replace mass air flow sensor.
8.
CHECK INTERMITTENT INCIDENT
GI-55, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000001162572
1.
CHECK MASS AIR FLOW SENSOR
Mass air flow sensor
Ground
Voltage
Connector
Terminal
F31
5
Ground
Approx. 5V
Mass air flow sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F31
2
F10
30
Existed
Mass air flow sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F31
6
F10
35
Existed