Nissan Quest E52. Instruction — part 1010
PWO-28
< DTC/CIRCUIT DIAGNOSIS >
[AC 120 V OUTLET]
AC 120 V POWER OUTPUT CIRCUIT
CAUTION:
• To measure AC 120 V output signal, always use the circuit tester AC range.
• Never allow the probes to contact each other.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace AC 120 V outlet.
Terminals
Condition
Standard value
Voltage
(Approx.)
(+)
(-)
AC 120 V outlet
AC 120 V outlet
main switch
Terminal
1
2
OFF
Approx. 0 V
0 V
ON
AC 108 – 132 V
AC 120 V
PWO
AC 120 V OUTLET MAIN SWITCH INDICATOR CIRCUIT
PWO-29
< DTC/CIRCUIT DIAGNOSIS >
[AC 120 V OUTLET]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
AC 120 V OUTLET MAIN SWITCH INDICATOR CIRCUIT
Diagnosis Procedure
INFOID:0000000009651888
1.
CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET MAIN SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect inverter unit connector and AC 120 V outlet main switch connector.
3.
Check continuity between inverter unit harness connector and AC 120 V main switch harness connector.
4.
Check continuity between inverter unit harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair the harnesses or connectors.
2.
CHECK AC 120 V OUTLET MAIN SWITCH GROUND CIRCUIT
Check continuity between AC 120 V outlet main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair the harnesses or connectors.
3.
CHECK AC 120 V OUTLET MAIN SWITCH INDICATOR OUTPUT SIGNAL
1.
Connect AC 120 V outlet main switch connector and inverter unit connector.
2.
Turn ignition switch ON.
3.
AC 120 V outlet main switch ON. (AC 120 V output is normal)
4.
Check for voltage between the inverter unit harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Replace inverter unit.
4.
CHECK AC 120 V OUTLET MAIN SWITCH INDICATOR
1.
AC 120 V outlet main switch ON. (AC 120 V output is normal)
2.
Check that AC 120 V outlet main switch indicator is illuminated.
Is the inspection result normal?
Inverter unit
AC 120 V outlet main switch
Continuity
Connector
Terminal
Connector
Terminal
B226
7
M24
5
Existed
Inverter unit
Ground
Continuity
Connector
Terminal
B226
7
Not existed
AC 120 V outlet main switch
Ground
Continuity
Connector
Terminal
M24
6
Existed
Terminals
Condition
Voltage
(Approx.)
(+)
(–)
Inverter unit
Ground
AC 120 V out-
let main
switch
Connector
Terminal
B226
7
OFF
0 V
ON
5.2 V
PWO-30
< DTC/CIRCUIT DIAGNOSIS >
[AC 120 V OUTLET]
AC 120 V OUTLET MAIN SWITCH INDICATOR CIRCUIT
YES
>> INSPECTION END
NO
>> Replace AC 120 V outlet main switch.
PWO
NO OUTPUT FROM AC 120 V OUTLET
PWO-31
< SYMPTOM DIAGNOSIS >
[AC 120 V OUTLET]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
SYMPTOM DIAGNOSIS
NO OUTPUT FROM AC 120 V OUTLET
Diagnosis Procedure
INFOID:0000000009651889
1.
CHECK FAIL-SAFE ACTIVATION
Check if the symptom is caused by a fail-safe operation. Refer to
.
Is fail-safe operating?
YES
>> Repair the part causing fail-safe operation.
NO
>> GO TO 2.
2.
CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Check inverter unit power supply circuit. Refer to
.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CHECK AC 120 V OUTLET MAIN SWITCH POWER SUPPLY CIRCUIT
Check AC 120 V outlet main switch power supply circuit. Refer to
.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the malfunctioning parts.
4.
CHECK AC 120 V OUTLET MAIN SWITCH INPUT SIGNAL CIRCUIT
Check AC 120 V outlet main switch input signal circuit. Refer to
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace the malfunctioning parts.
5.
CHECK INVERTER UNIT POWER OUTPUT CIRCUIT
Check inverter unit power output circuit. Refer to
.
Is the inspection result normal?
YES
>> Refer to
GI-42, "Intermittent Incident"
.
NO
>> Repair or replace the malfunctioning parts.