Nissan Quest E52. Instruction — part 406
DLK-338
< DTC/CIRCUIT DIAGNOSIS >
FUEL LID STATUS SWITCH
FUEL LID STATUS SWITCH
Component Function Check
INFOID:0000000009649280
1.
CHECK FUNCTION
1.
Select “AUTO SLDE DOOR” using CONSULT.
2.
Select “F LID SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Fuel filler lid status switch is OK.
NO
>> Refer to
DLK-338, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000009649281
1.
CHECK FUEL FILLER LID STATUS SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect fuel filler lid status switch connector.
3.
Check voltage between fuel filler lid status switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK FUEL FILLER LID STATUS SWITCH CIRCUIT
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and fuel filler lid status switch
harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK FUEL FILLER LID STATUS SWITCH GROUND CIRCUIT
Check continuity between fuel filler lid status switch LH harness connector and ground.
Monitor item
Condition
Status
F LID SW
Fuel filler lid status switch
ON
ON
OFF
OFF
(+)
(–)
Voltage
Fuel filler lid status switch
Connector
Terminal
B24
2
Ground
8 – 16 V
Sliding door control unit LH
Fuel filler lid status switch
Continuity
Connector
Terminal
Connector
Terminal
B45
17
B24
2
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
17
Not existed
FUEL LID STATUS SWITCH
DLK-339
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK FUEL FILLER LID STATUS SWITCH
DLK-339, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace fuel filler interlock assembly.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000009649282
1.
CHECK FUEL FILLER LID STATUS SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect fuel filler lid status switch connector.
3.
Check continuity between fuel filler lid status switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace fuel filler lid interlock assembly.
Fuel filler lid status switch
Ground
Continuity
Connector
Terminal
B24
1
Existed
Fuel filler lid status switch
Condition
Continuity
Terminal
2
1
Fuel filler lid status switch
ON
Existed
OFF
Not existed
DLK-340
< DTC/CIRCUIT DIAGNOSIS >
SLIDING DOOR OPEN/CLOSE SWITCH
SLIDING DOOR OPEN/CLOSE SWITCH
FRONT LH
FRONT LH : Component Function Check
INFOID:0000000009649283
1.
CHECK FUNCTION
1.
Select “AUTO SLDE DOOR” using CONSULT.
2.
Select “DRIVER SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Sliding door open/close switch (front LH) is OK.
NO
>> Refer to
DLK-340, "FRONT LH : Diagnosis Procedure"
FRONT LH : Diagnosis Procedure
INFOID:0000000009649284
1.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect sliding door open/close switch (front side) connector.
3.
Check voltage between sliding door open/close switch (front side) harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH CIRCUIT
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and sliding door open/close
switch (front side) harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH GROUND CIRCUIT
Check continuity between sliding door open/close switch (front side) harness connector and ground.
Monitor item
Condition
Status
DRIVER SW
Sliding door open/close switch
(front LH)
Pressed
ON
Released
OFF
(+)
(–)
Voltage
Sliding door open/close switch (front side)
Connector
Terminal
M90
2
Ground
8 – 16 V
Sliding door control unit LH
Sliding door open/close switch (front side)
Continuity
Connector
Terminal
Connector
Terminal
B45
19
M90
2
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
19
Not existed
SLIDING DOOR OPEN/CLOSE SWITCH
DLK-341
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH
DLK-341, "FRONT LH : Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace sliding door open/close switch (front side).
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
.
>> INSPECTION END
FRONT LH : Component Inspection
INFOID:0000000009649285
1.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect sliding door open/close switch (front side) connector.
3.
Check continuity between sliding door open/close switch (front side) terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace sliding door open/close switch (front side).
FRONT RH
FRONT RH : Component Function Check
INFOID:0000000009649286
1.
CHECK FUNCTION
1.
Select “AUTO SLDE DOOR RIGHT” using CONSULT.
2.
Select “DRIVER SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Sliding door open/close switch (front RH) is OK.
NO
>> Refer to
DLK-341, "FRONT RH : Diagnosis Procedure"
.
FRONT RH : Diagnosis Procedure
INFOID:0000000009649287
1.
CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect sliding door open/close switch (front side) connector.
Sliding door open/close switch (front side)
Ground
Continuity
Connector
Terminal
M90
3
Existed
Sliding door open/close switch (front side)
Condition
Continuity
Terminal
2
3
Sliding door open/close switch
(front LH)
Pressed
Existed
Released
Not existed
Monitor item
Condition
Status
DRIVER SW
Sliding door open/close switch
(front RH)
Pressed
ON
Released
OFF