Nissan Quest E52. Instruction — part 410
DLK-354
< DTC/CIRCUIT DIAGNOSIS >
SLIDING DOOR TOUCH SENSOR
3.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK SLIDING DOOR TOUCH SENSOR GROUND CIRCUIT 2
1.
Connect sliding door control unit RH connector and sliding door touch sensor RH connector.
2.
Check voltage between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace sliding door control unit RH. Refer to
DLK-500, "LH : Removal and Installation"
.
5.
CHECK SLIDING DOOR TOUCH SENSOR
DLK-354, "SLIDING DOOR RH : Component Inspection"
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace sliding door touch sensor RH.
6.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
>> INSPECTION END
SLIDING DOOR RH : Component Inspection
INFOID:0000000009649306
1.
CHECK SLIDING DOOR TOUCH SENSOR RH
1.
Turn ignition switch OFF.
2.
Disconnect sliding door touch sensor RH connector.
3.
Check resistance between sliding door touch sensor RH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace sliding door touch sensor RH.
Sliding door control unit RH
Sliding door touch sensor RH
Continuity
Connector
Terminal
Connector
Terminal
B247
23
D173
2
Existed
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B247
23
Not existed
(+)
(–)
Voltage
Sliding door control unit RH
Connector
Terminal
B247
23
Ground
0 V
Sliding door touch sensor RH
Condition
Resistance
Terminal
1
2
Sliding door touch sen-
sor RH
Detect obstruction
120
Ω
or less
Other than above
1 k
Ω
±
10%
CLUTCH
DLK-355
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
CLUTCH
SLIDING DOOR LH
SLIDING DOOR LH : Component Function Check
INFOID:0000000009649307
1.
CHECK FUNCTION
1.
Select “AUTO SLIDE DOOR” using CONSULT.
2.
Select “CLUTCH” in “ACTIVE TEST” mode.
3.
Touch “HOLD” and “RELEASE” to check that it works normally.
Is the inspection result normal?
YES
>> Clutch is OK.
NO
>> Refer to
DLK-355, "SLIDING DOOR LH : Diagnosis Procedure"
SLIDING DOOR LH : Diagnosis Procedure
INFOID:0000000009649308
1.
CHECK CLUTCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic sliding door unit LH connector.
3.
Check voltage between automatic sliding door unit LH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK CLUTCH CIRCUIT
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK CLUTCH GROUND CIRCUIT
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
(+)
(–)
Condition
Voltage
Automatic sliding door unit LH
Connector
Terminal
B33
2
Ground
Clutch
ON
9 – 16 V
OFF
0 V
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B47
47
B33
2
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B47
47
Not existed
DLK-356
< DTC/CIRCUIT DIAGNOSIS >
CLUTCH
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK CLUTCH CIRCUIT 2
1.
Connect sliding door control unit LH connector and automatic sliding door unit LH connector.
2.
Check voltage between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit LH.
NO
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
SLIDING DOOR RH
SLIDING DOOR RH : Component Function Check
INFOID:0000000009649309
1.
CHECK FUNCTION
1.
Select “AUTO SLIDE DOOR RIGHT” using CONSULT.
2.
Select “CLUTCH” in “ACTIVE TEST” mode.
3.
Touch “HOLD” and “RELEASE” to check that it works normally.
Is the inspection result normal?
YES
>> Clutch is OK.
NO
>> Refer to
DLK-355, "SLIDING DOOR LH : Diagnosis Procedure"
SLIDING DOOR RH : Diagnosis Procedure
INFOID:0000000009649310
1.
CHECK CLUTCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic sliding door unit RH connector.
3.
Check voltage between automatic sliding door unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK CLUTCH CIRCUIT
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B47
44
B33
1
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B47
44
Not existed
(+)
(–)
Voltage
Sliding door control unit LH
Connector
Terminal
B47
44
Ground
0 V
(+)
(–)
Condition
Voltage
Automatic sliding door unit RH
Connector
Terminal
B245
2
Ground
Clutch
ON
9 – 16 V
OFF
0 V
CLUTCH
DLK-357
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
1.
Disconnect sliding door control unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit RH. Refer to
DLK-500, "RH : Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK CLUTCH GROUND CIRCUIT
1.
Disconnect sliding door control unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK CLUTCH CIRCUIT 2
1.
Connect sliding door control unit RH connector and automatic sliding door unit RH connector.
2.
Check voltage between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit RH.
NO
>> Replace sliding door control unit RH. Refer to
DLK-500, "RH : Removal and Installation"
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B249
47
B245
2
Existed
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B249
47
Not existed
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B249
44
B245
1
Existed
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B249
44
Not existed
(+)
(–)
Voltage
Sliding door control unit RH
Connector
Terminal
B249
44
Ground
0 V