Nissan Quest E52. Instruction — part 409

DLK-350

< DTC/CIRCUIT DIAGNOSIS >

SLIDING DOOR ONE-TOUCH OPEN/CLOSE SWITCH

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR ONE-TOUCH OPEN/CLOSE SWITCH CIRCUIT 2

1.

Connect sliding door control unit RH connector and sliding door one-touch open/close switch RH connec-
tor.

2.

Check voltage between sliding door one-touch open/close switch RH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door control unit RH. Refer to

DLK-500, "RH : Removal and Installation"

.

5.

CHECK SLIDING DOOR ONE-TOUCH OPEN/CLOSE SWITCH

Refer to

DLK-350, "SLIDING DOOR RH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace sliding door one-touch open/close switch RH.

6.

CHECK INTERMITTENT INCIDENT

Refer to

GI-42, "Intermittent Incident"

.

>> INSPECTION END

SLIDING DOOR RH : Component Inspection

INFOID:0000000009649300

1.

CHECK SLIDING DOOR ONE-TOUCH OPEN/CLOSE SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door one-touch open/close switch RH connector.

3.

Check continuity between sliding door one-touch open/close switch RH terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door one-touch open/close switch RH.

Sliding door control unit RH

Sliding door one-touch open/close switch RH

Continuity

Connector

Terminal

Connector

Terminal

B247

23

D126

2

Existed

Sliding door control unit RH

Ground

Continuity

Connector

Terminal

B247

23

Not existed

(+)

(–)

Voltage

Sliding door control unit RH

Connector

Terminal

B247

23

Ground

0 V

Sliding door one-touch open/close switch

RH

Condition

Continuity

Terminal

1

2

Sliding door one-touch open/
close switch RH

Pressed

Existed

Released

Not existed

SLIDING DOOR TOUCH SENSOR

DLK-351

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

SLIDING DOOR TOUCH SENSOR

SLIDING DOOR LH

SLIDING DOOR LH : Component Function Check

INFOID:0000000009649301

1.

CHECK FUNCTION

1.

Select “AUTO SLIDE DOOR” using CONSULT.

2.

Select “TOUCH SEN LH” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door touch sensor is OK.

NO

>> Refer to

DLK-351, "SLIDING DOOR LH : Diagnosis Procedure"

.

SLIDING DOOR LH : Diagnosis Procedure

INFOID:0000000009649302

1.

CHECK SLIDING DOOR TOUCH SENSOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Check voltage between sliding door touch sensor LH harness connector and sliding door control unit LH
harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR TOUCH SENSOR CIRCUIT

1.

Disconnect sliding door control unit LH and sliding door touch sensor LH connector.

2.

Check continuity between sliding door control unit LH harness connector and sliding door touch sensor
LH harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit LH. Refer to

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR TOUCH SENSOR GROUND CIRCUIT

1.

Disconnect sliding door control unit LH and sliding door touch sensor LH connectors.

Monitor item

Condition

Status

TOUCH SEN LH

Sliding door touch sensor LH

Other than below

OFF

Detect obstruction

ON

(+)

(–)

Condition

Voltage

Sliding door touch sensor

LH

Sliding door control unit

LH

Connector

Terminal

Connector

Terminal

D172

1

B45

23

Sliding door touch
sensor LH

Detect obstruction

0 – 1.5 V

Other than above

4 – 8 V

Sliding door control unit LH

Sliding door touch sensor LH

Continuity

Connector

Terminal

Connector

Terminal

B45

24

D172

1

Existed

Sliding door control unit LH

Ground

Continuity

Connector

Terminal

B45

24

Not existed

DLK-352

< DTC/CIRCUIT DIAGNOSIS >

SLIDING DOOR TOUCH SENSOR

2.

Check continuity between sliding door control unit LH harness connector and sliding door touch sensor
LH harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR TOUCH SENSOR GROUND CIRCUIT 2

1.

Connect sliding door control unit LH connector and sliding door touch sensor LH connector.

2.

Check voltage between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door control unit LH. Refer to

DLK-500, "LH : Removal and Installation"

.

5.

CHECK SLIDING DOOR TOUCH SENSOR

Refer to

DLK-352, "SLIDING DOOR LH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace sliding door touch sensor LH.

6.

CHECK INTERMITTENT INCIDENT

Refer to

GI-42, "Intermittent Incident"

.

>> INSPECTION END

SLIDING DOOR LH : Component Inspection

INFOID:0000000009649303

1.

CHECK SLIDING DOOR TOUCH SENSOR LH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door touch sensor LH connector.

3.

Check resistance between sliding door touch sensor LH terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door touch sensor LH.

SLIDING DOOR RH

Sliding door control unit LH

Sliding door touch sensor LH

Continuity

Connector

Terminal

Connector

Terminal

B45

23

D172

2

Existed

Sliding door control unit LH

Ground

Continuity

Connector

Terminal

B45

23

Not existed

(+)

(–)

Voltage

Sliding door control unit LH

Connector

Terminal

B45

23

Ground

0 V

Sliding door touch sensor LH

Condition

Resistance

Terminal

1

2

Sliding door touch sen-
sor RH

Detect obstruction

120

or less

Other than above

1 k

±

10%

SLIDING DOOR TOUCH SENSOR

DLK-353

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

SLIDING DOOR RH : Component Function Check

INFOID:0000000009649304

1.

CHECK FUNCTION

1.

Select “AUTO SLIDE DOOR RIGHT” using CONSULT.

2.

Select “TOUCH SEN RH” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door touch sensor is OK.

NO

>> Refer to

DLK-353, "SLIDING DOOR RH : Diagnosis Procedure"

.

SLIDING DOOR RH : Diagnosis Procedure

INFOID:0000000009649305

1.

CHECK SLIDING DOOR TOUCH SENSOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Check voltage between sliding door touch sensor RH harness connector and sliding door control unit RH
harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR TOUCH SENSOR CIRCUIT

1.

Disconnect sliding door control unit RH connector and sliding door touch sensor RH connector.

2.

Check continuity between sliding door control unit RH harness connector and sliding door touch sensor
RH harness connector.

3.

Check continuity between sliding door control unit RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit RH. Refer to

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR TOUCH SENSOR GROUND CIRCUIT

1.

Disconnect sliding door control unit RH connector and sliding door touch sensor RH connectors.

2.

Check continuity between sliding door control unit RH harness connector and sliding door touch sensor
RH harness connector.

Monitor item

Condition

Status

TOUCH SEN RH

Sliding door touch sensor RH

Other than below

OFF

Detect obstruction

ON

(+)

(–)

Condition

Voltage

Sliding door touch sensor

RH

Sliding door control unit

RH

Connector

Terminal

Connector

Terminal

D173

1

B247

23

Sliding door touch
sensor RH

Detect obstruction

0 – 1.5 V

Other than above

4 – 8 V

Sliding door control unit RH

Sliding door touch sensor RH

Continuity

Connector

Terminal

Connector

Terminal

B247

24

D173

1

Existed

Sliding door control unit RH

Ground

Continuity

Connector

Terminal

B247

24

Not existed