Nissan Juke F15. Instruction — part 739
EXL-176
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN TYPE]
DAYTIME RUNNING LIGHT RELAY CIRCUIT
5. With operating the test item, check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Daytime running light relay circuit is normal.
NO-1 >> Fixed at 0 – 1 V: GO TO 6.
NO-2 >> Fixed at 9 – 16 V: GO TO 5.
5.
CHECK DAYTIME RUNNING LIGHT REQUEST SIGNAL
With CONSULT
1. Select “DTRL REQ” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
2. With operating the daytime running light ON condition, check the monitor status.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
6.
CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL CIRCUIT
1. Turn ignition switch OFF.
2. Remove daytime running light relay.
3. Disconnect IPDM E/R harness connector.
4. Check continuity between IPDM E/R harness connector and daytime running light relay harness connec-
tor.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
NO
>> Repair or replace harness.
Component Inspection
INFOID:0000000012201756
1.
CHECK DAYTIME RUNNING LIGHT RELAY
1. Turn ignition switch OFF.
2. Remove daytime running light relay.
3. Apply battery voltage to daytime running light relay between terminals 1 and 2.
4. Check continuity of daytime running light relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
+
-
Test item
Voltage
IPDM E/R
Connector
Terminal
E13
28
Ground
DAYTIME RUNNING LIGHT
On
0 – 1 V
Off
9 – 16 V
Monitor item
Condition
Monitor status
DTRL REQ
Daytime running light
ON condition
On
OFF condition
Off
IPDM E/R
Daytime running light relay
Continuity
Connector
Terminal
Connector
Terminal
E13
28
E65
2
Existed
Daytime running light relay
Condition
Continuity
Terminal
5
3
Battery voltage
Apply
Existed
Not apply
Not existed
DAYTIME RUNNING LIGHT RELAY CIRCUIT
EXL-177
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
NO
>> Replace daytime running light relay.
EXL-178
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN TYPE]
DAYTIME RUNNING LIGHT CIRCUIT
DAYTIME RUNNING LIGHT CIRCUIT
Component Function Check
INFOID:0000000012201757
1.
CHECK DAYTIME RUNNING LIGHT OPERATION
With CONSULT
1. Select “EXTERNAL LAMPS” in “Active Test” mode of “IPDM E/R” using CONSULT.
2. With operating the test items, check that the daytime running light is turned ON.
Without CONSULT
1. Start IPDM E/R auto active test. Refer to
PCS-12, "Diagnosis Description"
2. Check that the daytime running light is turned ON.
Is the measurement normal?
YES
>> Daytime running light circuit is normal.
NO
>> Refer to
EXL-178, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000012201758
1.
CHECK DAYTIME RUNNING LIGHT FUSE
1. Turn ignition switch OFF.
2. Check that the following fuse is not blown (open).
Is the fuse blown (open)?
YES
>> Replace the blown fuse after repairing the affected circuit if a fuse is blown (open).
NO
>> GO TO 2.
2.
CHECK DAYTIME RUNNING LIGHT POWER SUPPLY
With CONSULT
1. Turn ignition switch ON.
2. Select “EXTERNAL LAMPS” in “Active Test” mode of “IPDM E/R” using CONSULT.
3. With operating the test items, check the voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
3.
CHECK DAYTIME RUNNING LIGHT POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and daytime running light connector.
3. Check continuity between IPDM E/R harness connector and daytime running light harness connector.
Fog
: Daytime running light ON
Off
: Daytime running light OFF
Unit
Location
Fuse No.
Capacity
Daytime running light
IPDM E/R
#50
15 A
+
-
Test item
Voltage
IPDM E/R
Connector
Terminal
RH
E12
19
Ground
EXTERNAL
LAMPS
Fog
9 – 16 V
Off
0 – 1 V
LH
20
Fog
9 – 16 V
Off
0 – 1 V
DAYTIME RUNNING LIGHT CIRCUIT
EXL-179
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN TYPE]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DAYTIME RUNNING LIGHT GROUND CIRCUIT
Check continuity between daytime running light harness connector and ground.
Is the inspection result normal?
YES
>> Replace the corresponding daytime running light. Refer to
EXL-212, "Removal and Installation"
NO
>> Repair or replace harness.
IPDM E/R
Daytime running light
Continuity
Connector
Terminal
Connector
Terminal
RH
E12
19
E75
1
Existed
LH
20
E76
Daytime running light
—
Continuity
Connector
Terminal
RH
E75
2
Ground
Existed
LH
E76