Jaguar X-Type Sedan and Estate (Wagon). Service manual — part 660
- The roof opening glass will close until the roof opening panel switch is pressed in any direction or the roof opening glass
reaches the full closed position.
Press the rear of the switch to the first detent with the roof opening glass in a vent up position.
- The roof opening glass will close until the roof opening panel switch is released or the roof opening glass reaches the full closed
position.
Press the rear of the switch to the second detent with the roof opening glass in a vent up position.
- The roof opening glass will close until the roof opening panel switch is pressed in any direction or the roof opening glass
reaches the full closed position.
Global Closing Operation
The roof opening panel is included in the global close operation. This function closes the power windows and the roof opening panel
automatically. For additional information on the global close feature for the power windows, refer to Section
501-11 Glass, Frames and
Mechanisms
.
The global close function is activated by:
turning the driver door lock cylinder to the lock position and holding.
Global close operation is only available with the ignition in the OFF position and the ignition key removed.
When the global close operation is selected, the roof opening panel switch is not recognized by the roof opening panel control module
throughout the operation and for five seconds after the operation is completed.
Global close will operate as follows.
With the roof opening glass in the open position, activating global close will close the roof opening glass to the flush position.
*
*
*
*
*
*
*
Published: 11-May-2011
Roof Opening Panel - Roof Opening Panel
Diagnosis and Testing
Principles of Operation
Roof Opening Panel Control Module
Battery power is continuously supplied to the roof opening panel control module. However, the roof opening panel will only operate from the
roof opening panel switch with the ignition switch in the RUN or ACCY position. The global close feature is controlled by two circuits from
the generic electronics control module (GEM). The two circuits must be at ground potential before the roof opening panel control module will
acknowledge the roof opening panel switch. When the ignition switch is turned to RUN or ACCY, the GEM provides ground to these circuits.
The roof opening panel control module incorporates soft stops at the end of all travel positions. The roof opening panel control module
monitors the internal switches to determine the roof opening glass position and the soft stops. The internal switches are activated by the
roof opening panel motor rotation.
The roof opening panel control module supplies the power and ground to the roof opening panel motor depending on the ordered function.
Power is supplied to the roof opening panel for a maximum of 12 seconds. Under normal operation, position is monitored by the roof
opening panel control module and power is removed from the roof opening panel motor as soon as the roof opening panel reaches the
commanded position.
Roof Opening Panel Switch
Two circuits connect the roof opening panel switch to the roof opening panel control module. One circuit controls open and down operation.
The other circuit controls the tilt and close operation. The roof opening panel control module monitors these lines for voltage fluctuation to
determine which function was selected.
With the ignition switch in the RUN or ACCY position, the roof opening panel supplies a five volt reference voltage to three control lines.
Activation of the roof opening panel switch connects one or more of these lines to the common return which pulls the line low. The roof
opening panel control module will sense the line or lines being connected to the common line and carry out the appropriate function.
The express open function connects the open and tilt circuits to the common return when the roof opening panel switch is moved rearward
to the second detent position. The operator-controlled open function connects the open circuit to the common return. The close function
connects the close circuit to the common causing the roof opening panel to close from a slide or vent position.
Global Close
One circuit connects the GEM to the roof opening panel control module for this function. Global close operation for the roof opening panel is
controlled by this circuit being grounded by the GEM.
When the ignition switch is in the RUN or ACCY position, the GEM grounds this circuit allowing normal operation of the roof opening panel
from the roof opening panel switch. Global close operation is only available with the ignition in the OFF position and the ignition key
removed.
When global close operation is selected, the roof opening panel switch is not recognized by the roof opening panel control module
throughout the operation and for five seconds after the operation is completed.
With the ignition switch in the OFF position, the roof opening panel control module supplies a constant voltage to this circuit. The roof
opening panel control module monitors these lines for a low state, caused by the GEM grounding the line, to determine the ordered global
function by the GEM.
Global close is commanded by the GEM grounding control line one. Line two will remain at previous voltage.
If both lines have voltage, the roof opening panel will be inoperative.
Inspection and Verification
1. Verify the customer concern by operating the system.
1.
2. Visually inspect for obvious signs of mechanical and electrical damage.
2.
Visual Inspection Chart
Mechanical
Electrical
Roof opening panel track and rail assembly
Roof opening panel glass seal
Roof opening panel glass adjustment
Roof opening panel synchronization
Central junction box (CJB) fuse 73 (15A)
Damaged, loose or corroded connectors
W iring harness
Roof opening panel switch
Roof opening panel motor
Roof opening panel control module
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next
step.
3.
4. If the concern is not visually evident, verify the symptom and refer to the Symptom Chart.
4.
Symptom Chart
Refer to the Wiring Diagram manual for the connectors cited in the pinpoint tests.
SYMPTOM CHART
Symptom
Possible Sources
Action
The roof opening panel has excessive wind noise
Incorrect adjustment.
Roof opening panel glass seal.
GO to Pinpoint Test A.
The roof opening panel leaks
Incorrect adjustment.
Roof opening panel frame drain
hoses.
Roof opening panel glass seal.
GO to Pinpoint Test B.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
1
2
1
1
1
1
1
1
The roof opening panel is noisy during operation
Roof opening panel glass.
Roof opening panel.
Roof opening panel motor.
GO to Pinpoint Test C.
The roof opening panel does not open or close
Roof opening panel.
Roof opening panel control
module.
Roof opening panel motor.
Generic electronics module (GEM).
Roof opening panel switch.
Circuitry.
GO to the approved Jaguar diagnostic
system.
The roof opening panel does not open or close in vent
position
Roof opening panel control
module.
Roof opening panel switch.
Circuitry.
GO to the approved Jaguar diagnostic
system.
The roof opening panel does not stop in flush from any
position.
Roof opening panel adjustment.
Roof opening panel glass seal.
Roof opening panel control
module.
GO to Pinpoint Test D.
The express open is inoperative
Roof opening panel control
module.
Roof opening panel switch.
Circuitry.
GO to the approved Jaguar diagnostic
system.
PINPOINT TEST A : THE ROOF OPENING PANEL HAS EXCESSIVE WIND NOISE
TEST
CONDITIONS
DETAILS/RESULTS/ACTIONS
A1: CHECK THE ROOF OPENING GLASS FIT
Cycle the roof opening glass from the full-open to the full-closed position.
Inspect the roof opening glass seal for proper fit or damage.
Is the roof opening glass seal OK?
Yes
GO to A2
.
No
INSTALL a new roof opening glass seal. REFER to
Seal
. Test the system for normal operation.
A2: CHECK THE ROOF OPENING GLASS OPERATION
Cycle the roof opening glass from the full-open to the full-closed position.
Does the roof opening glass travel to the full-open and the full-closed position?
Yes
ADJUST the roof opening glass. REFER to
Roof Opening Panel Alignment
. If the roof opening glass closes unevenly,
CHECK the roof opening panel syncronization. REFER to Section
100-00 General InformationMotor Synchronization
—Calibration
. Test the system for normal operation.
No
CHECK the roof opening panel glass seal. If necessary, INSTALL a new roof opening panel glass seal. REFER to
Seal
.
TEST the system for normal operation.
PINPOINT TEST B : THE ROOF OPENING PANEL LEAKS
TEST
CONDITIONS
DETAILS/RESULTS/ACTIONS
B1: CHECK THE ROOF OPENING PANEL OPERATION
Cycle the roof opening panel glass from the full-open position to the full-closed position.
Does the roof opening glass operate smoothly and close tightly?
Yes
GO to B2
.
No
CHECK the roof opening panel glass alignment. REFER to
Roof Opening Panel Alignment
. Test the system for
normal operation.
B2: CHECK THE ROOF OPENING PANEL FRAME DRAIN TUBES
Gain access to the roof opening panel drain tubes.
Is there blockage or damage to the roof opening panel drain tubes?
Yes
Clear the blockage or if necessary, INSTALL a new drain tube. TEST the system for normal operation.
No
GO to B3
.
B3: CHECK THE ROOF OPENING PANEL GLASS SEAL
Actuate the roof opening panel glass to the full open position.
Is the roof opening panel glass seal damaged?
Yes
INSTALL a new roof opening panel glass seal. REFER to
Seal
. TEST the system for normal operation.
No
REPAIR as necessary. TEST the system for normal operation.
PINPOINT TEST C : THE ROOF OPENING PANEL IS NOISY DURING OPERATION
TEST
CONDITIONS
DETAILS/RESULTS/ACTIONS
C1: CHECK THE OPERATION OF THE ROOF OPENING PANEL GLASS
Cycle the roof opening panel glass from the full-open to the full-closed position.
Is the roof opening panel glass loose?
Yes
ADJUST the roof opening panel glass. REFER to
Roof Opening Panel Alignment
No
GO to C2
.
C2: CHECK FOR OBSTRUCTIONS
Check the roof opening panel track and rail for foreign material, damage or looseness.
Is the roof opening panel obstructed or damaged?
Yes
REMOVE the obstruction. If necessary, INSTALL a new roof opening panel frame. REFER to
Roof Opening Panel Frame
.
TEST the system for normal operation.
1
1
1
1
No
GO to C3
.
C3: CHECK THE ROOF OPENING PANEL MOTOR
Cycle the roof opening glass from the full-open to the full-closed position.
Does the roof opening panel motor make excessive noise?
Yes
CHECK the roof opening panel motor for correct mounting. If necessary, INSTALL a new roof opening panel motor .
REFER to
Roof Opening Panel Motor
TEST the system for normal operation. If the roof opening panel opens or closes
unevenly, ADJUST the roof opening panel motor syncronization. REFER to
Motor Synchronization—Calibration
No
REFER to
Roof Opening Panel Alignment
ADJUST the roof opening panel glass as necessary. TEST the system for
normal operation.
PINPOINT TEST D : THE ROOF OPENING PANEL DOES NOT STOP IN FLUSH FROM ANY POSITION
TEST
CONDITIONS
DETAILS/RESULTS/ACTIONS
D1: CHECK THE ROOF OPENING PANEL GLASS ADJUSTMENT
Check the roof opening panel glass alignment. For additional information, refer to
Roof Opening Panel Alignment
.
Is the roof opening panel glass adjusted correctly?
Yes
GO to D2
.
No
ADJUST the roof opening panel glass as necessary. TEST the system for normal operation.
D2: CHECK THE ROOF OPENING GLASS SEAL
Inspect the roof opening panel glass seal for looseness, damage and correct installation.
Is the roof opening panel glass seal OK and installed correctly?
Yes
GO to D3
.
No
REPAIR or INSTALL a new roof opening panel glass seal as necessary. For additional information, refer to
Seal
. TEST
the system for normal operation.
D3: CHECK FOR OBSTRUCTION IN THE ROOF OPENING PANEL
Inspect the roof opening panel assembly for obstructions in the track.
Are any obstructions found?
Yes
REMOVE the obstruction. If necessary, INSTALL a new roof opening panel track and rail assembly. For additional
information, refer to
Roof Opening Panel Frame
. TEST the system for normal operation.
No
INSTALL a new roof opening panel control module. For additional information, refer to
Roof Opening Panel Motor