Jaguar X-Type Sedan and Estate (Wagon). Service manual — part 660

- The roof opening glass will close until the roof opening panel switch is pressed in any direction or the roof opening glass
reaches the full closed position.

Press the rear of the switch to the first detent with the roof opening glass in a vent up position.

- The roof opening glass will close until the roof opening panel switch is released or the roof opening glass reaches the full closed
position.

Press the rear of the switch to the second detent with the roof opening glass in a vent up position.

- The roof opening glass will close until the roof opening panel switch is pressed in any direction or the roof opening glass
reaches the full closed position.

Global Closing Operation

The roof opening panel is included in the global close operation. This function closes the power windows and the roof opening panel
automatically. For additional information on the global close feature for the power windows, refer to Section

501-11 Glass, Frames and

Mechanisms

.

The global close function is activated by:

turning the driver door lock cylinder to the lock position and holding.

Global close operation is only available with the ignition in the OFF position and the ignition key removed.

When the global close operation is selected, the roof opening panel switch is not recognized by the roof opening panel control module
throughout the operation and for five seconds after the operation is completed.

Global close will operate as follows.

With the roof opening glass in the open position, activating global close will close the roof opening glass to the flush position.

*
*

*

*
*

*

*

Published: 11-May-2011

Roof Opening Panel - Roof Opening Panel

Diagnosis and Testing

Principles of Operation

Roof Opening Panel Control Module

Battery power is continuously supplied to the roof opening panel control module. However, the roof opening panel will only operate from the
roof opening panel switch with the ignition switch in the RUN or ACCY position. The global close feature is controlled by two circuits from
the generic electronics control module (GEM). The two circuits must be at ground potential before the roof opening panel control module will
acknowledge the roof opening panel switch. When the ignition switch is turned to RUN or ACCY, the GEM provides ground to these circuits.

The roof opening panel control module incorporates soft stops at the end of all travel positions. The roof opening panel control module
monitors the internal switches to determine the roof opening glass position and the soft stops. The internal switches are activated by the
roof opening panel motor rotation.

The roof opening panel control module supplies the power and ground to the roof opening panel motor depending on the ordered function.
Power is supplied to the roof opening panel for a maximum of 12 seconds. Under normal operation, position is monitored by the roof
opening panel control module and power is removed from the roof opening panel motor as soon as the roof opening panel reaches the
commanded position.

Roof Opening Panel Switch

Two circuits connect the roof opening panel switch to the roof opening panel control module. One circuit controls open and down operation.
The other circuit controls the tilt and close operation. The roof opening panel control module monitors these lines for voltage fluctuation to
determine which function was selected.

With the ignition switch in the RUN or ACCY position, the roof opening panel supplies a five volt reference voltage to three control lines.
Activation of the roof opening panel switch connects one or more of these lines to the common return which pulls the line low. The roof
opening panel control module will sense the line or lines being connected to the common line and carry out the appropriate function.

The express open function connects the open and tilt circuits to the common return when the roof opening panel switch is moved rearward
to the second detent position. The operator-controlled open function connects the open circuit to the common return. The close function
connects the close circuit to the common causing the roof opening panel to close from a slide or vent position.

Global Close

One circuit connects the GEM to the roof opening panel control module for this function. Global close operation for the roof opening panel is
controlled by this circuit being grounded by the GEM.

When the ignition switch is in the RUN or ACCY position, the GEM grounds this circuit allowing normal operation of the roof opening panel
from the roof opening panel switch. Global close operation is only available with the ignition in the OFF position and the ignition key
removed.

When global close operation is selected, the roof opening panel switch is not recognized by the roof opening panel control module
throughout the operation and for five seconds after the operation is completed.

With the ignition switch in the OFF position, the roof opening panel control module supplies a constant voltage to this circuit. The roof
opening panel control module monitors these lines for a low state, caused by the GEM grounding the line, to determine the ordered global
function by the GEM.

Global close is commanded by the GEM grounding control line one. Line two will remain at previous voltage.

If both lines have voltage, the roof opening panel will be inoperative.

Inspection and Verification

1. Verify the customer concern by operating the system.

1.

2. Visually inspect for obvious signs of mechanical and electrical damage.

2.

Visual Inspection Chart

Mechanical

Electrical

Roof opening panel track and rail assembly
Roof opening panel glass seal
Roof opening panel glass adjustment
Roof opening panel synchronization

Central junction box (CJB) fuse 73 (15A)
Damaged, loose or corroded connectors
W iring harness
Roof opening panel switch
Roof opening panel motor
Roof opening panel control module

3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next

step.

3.

4. If the concern is not visually evident, verify the symptom and refer to the Symptom Chart.

4.

Symptom Chart

Refer to the Wiring Diagram manual for the connectors cited in the pinpoint tests.

SYMPTOM CHART

Symptom

Possible Sources

Action

The roof opening panel has excessive wind noise

Incorrect adjustment.
Roof opening panel glass seal.

GO to Pinpoint Test A.

The roof opening panel leaks

Incorrect adjustment.
Roof opening panel frame drain
hoses.
Roof opening panel glass seal.

GO to Pinpoint Test B.

*
*
*

*

*
*

*
*
*
*

*

*

*
*

*

*
*
*

*

*

*
*

*

1
2

1

1

1

1

1

1

The roof opening panel is noisy during operation

Roof opening panel glass.
Roof opening panel.
Roof opening panel motor.

GO to Pinpoint Test C.

The roof opening panel does not open or close

Roof opening panel.
Roof opening panel control
module.
Roof opening panel motor.
Generic electronics module (GEM).
Roof opening panel switch.
Circuitry.

GO to the approved Jaguar diagnostic
system.

The roof opening panel does not open or close in vent
position

Roof opening panel control
module.
Roof opening panel switch.
Circuitry.

GO to the approved Jaguar diagnostic
system.

The roof opening panel does not stop in flush from any
position.

Roof opening panel adjustment.
Roof opening panel glass seal.
Roof opening panel control
module.

GO to Pinpoint Test D.

The express open is inoperative

Roof opening panel control
module.
Roof opening panel switch.
Circuitry.

GO to the approved Jaguar diagnostic
system.

PINPOINT TEST A : THE ROOF OPENING PANEL HAS EXCESSIVE WIND NOISE

TEST

CONDITIONS

DETAILS/RESULTS/ACTIONS

A1: CHECK THE ROOF OPENING GLASS FIT

Cycle the roof opening glass from the full-open to the full-closed position.
Inspect the roof opening glass seal for proper fit or damage.

Is the roof opening glass seal OK?
Yes

GO to A2

.

No

INSTALL a new roof opening glass seal. REFER to

Seal

. Test the system for normal operation.

A2: CHECK THE ROOF OPENING GLASS OPERATION

Cycle the roof opening glass from the full-open to the full-closed position.

Does the roof opening glass travel to the full-open and the full-closed position?
Yes

ADJUST the roof opening glass. REFER to

Roof Opening Panel Alignment

. If the roof opening glass closes unevenly,

CHECK the roof opening panel syncronization. REFER to Section

100-00 General InformationMotor Synchronization

—Calibration

. Test the system for normal operation.

No

CHECK the roof opening panel glass seal. If necessary, INSTALL a new roof opening panel glass seal. REFER to

Seal

.

TEST the system for normal operation.

PINPOINT TEST B : THE ROOF OPENING PANEL LEAKS

TEST

CONDITIONS

DETAILS/RESULTS/ACTIONS

B1: CHECK THE ROOF OPENING PANEL OPERATION

Cycle the roof opening panel glass from the full-open position to the full-closed position.

Does the roof opening glass operate smoothly and close tightly?
Yes

GO to B2

.

No

CHECK the roof opening panel glass alignment. REFER to

Roof Opening Panel Alignment

. Test the system for

normal operation.

B2: CHECK THE ROOF OPENING PANEL FRAME DRAIN TUBES

Gain access to the roof opening panel drain tubes.

Is there blockage or damage to the roof opening panel drain tubes?
Yes

Clear the blockage or if necessary, INSTALL a new drain tube. TEST the system for normal operation.

No

GO to B3

.

B3: CHECK THE ROOF OPENING PANEL GLASS SEAL

Actuate the roof opening panel glass to the full open position.

Is the roof opening panel glass seal damaged?
Yes

INSTALL a new roof opening panel glass seal. REFER to

Seal

. TEST the system for normal operation.

No

REPAIR as necessary. TEST the system for normal operation.

PINPOINT TEST C : THE ROOF OPENING PANEL IS NOISY DURING OPERATION

TEST

CONDITIONS

DETAILS/RESULTS/ACTIONS

C1: CHECK THE OPERATION OF THE ROOF OPENING PANEL GLASS

Cycle the roof opening panel glass from the full-open to the full-closed position.

Is the roof opening panel glass loose?
Yes

ADJUST the roof opening panel glass. REFER to

Roof Opening Panel Alignment

No

GO to C2

.

C2: CHECK FOR OBSTRUCTIONS

Check the roof opening panel track and rail for foreign material, damage or looseness.

Is the roof opening panel obstructed or damaged?
Yes

REMOVE the obstruction. If necessary, INSTALL a new roof opening panel frame. REFER to

Roof Opening Panel Frame

.

TEST the system for normal operation.

1

1

1

1

No

GO to C3

.

C3: CHECK THE ROOF OPENING PANEL MOTOR

Cycle the roof opening glass from the full-open to the full-closed position.

Does the roof opening panel motor make excessive noise?
Yes

CHECK the roof opening panel motor for correct mounting. If necessary, INSTALL a new roof opening panel motor .
REFER to

Roof Opening Panel Motor

TEST the system for normal operation. If the roof opening panel opens or closes

unevenly, ADJUST the roof opening panel motor syncronization. REFER to

Motor Synchronization—Calibration

No

REFER to

Roof Opening Panel Alignment

ADJUST the roof opening panel glass as necessary. TEST the system for

normal operation.

PINPOINT TEST D : THE ROOF OPENING PANEL DOES NOT STOP IN FLUSH FROM ANY POSITION

TEST

CONDITIONS

DETAILS/RESULTS/ACTIONS

D1: CHECK THE ROOF OPENING PANEL GLASS ADJUSTMENT

Check the roof opening panel glass alignment. For additional information, refer to

Roof Opening Panel Alignment

.

Is the roof opening panel glass adjusted correctly?
Yes

GO to D2

.

No

ADJUST the roof opening panel glass as necessary. TEST the system for normal operation.

D2: CHECK THE ROOF OPENING GLASS SEAL

Inspect the roof opening panel glass seal for looseness, damage and correct installation.

Is the roof opening panel glass seal OK and installed correctly?
Yes

GO to D3

.

No

REPAIR or INSTALL a new roof opening panel glass seal as necessary. For additional information, refer to

Seal

. TEST

the system for normal operation.

D3: CHECK FOR OBSTRUCTION IN THE ROOF OPENING PANEL

Inspect the roof opening panel assembly for obstructions in the track.

Are any obstructions found?
Yes

REMOVE the obstruction. If necessary, INSTALL a new roof opening panel track and rail assembly. For additional
information, refer to

Roof Opening Panel Frame

. TEST the system for normal operation.

No

INSTALL a new roof opening panel control module. For additional information, refer to

Roof Opening Panel Motor

Была ли эта страница вам полезна?
Да!Нет
5 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности