Chery Tiggo 5 (T21). Service manual — part 344
31–
80
31
g. Disconnect the connector (arrow) connecting A/C wire
harness assembly and instrument panel wire harness
assembly.
h. Carefully take off the HVAC assembly from the cabin.
Disassembly
1. Remove the A/C element (
).
2. Remove the blower assembly (
3. Remove the blower speed resistor (
).
4. Remove the inner/outer circulation damper motor (
5. Remove the mode damper servo motor (
6. Remove the mix damper servo motor (
).
7. Remove the HVAC assembly transition duct.
a. Detach the claws (arrow) on both sides and remove
the transition duct (1) from the HVAC assembly.
8. Remove the air inlet assembly.
a. Remove the air inlet assembly right fixing screw
(arrow) and detach the fixing claws (1).
(Tightening torque: 2.5 ± 0.5 N·m)
RT21310320
1
RT21310330
1
RT21310340
31–
81
31
b. Remove 2 fixing screws (arrow) from the left side of
air inlet assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
c. Remove the air inlet assembly.
9. Remove the inner/outer circulation damper set.
a. Remove the air inlet assembly grommet (arrow) and
detach the fixing claw (1) on front part.
b. Remove the air inlet assembly rear fixing screw
(arrow) and detach the fixing claws (1).
(Tightening torque: 2.5 ± 0.5 N·m)
c. Detach the air inlet housing assembly and remove the
inner/outer circulation damper set.
RT21310350
1
RT21310360
1
RT21310370
RT21310380
31–
82
31
10.Remove the left foot fan shield.
a. Remove the fixing screw (arrow), detach the fixing
claw and detach the left foot fan shield (1) from the
HVAC assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
11.Remove the right foot fan shield.
a. Remove the fixing screw (arrow), detach the fixing
claw and detach the right foot fan shield (1) from the
HVAC assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
12.Remove the expansion valve.
a. Remove the evaporator core line grommet (arrow).
b. Remove 2 fixing bolts (arrow) between expansion
valve and expansion valve mounting pressure plate.
(Tightening torque: 7 ± 1 N·m)
1
RT21310390
1
RT21310400
RT21310410
RT21310420
31–
83
31
c. Detach the A/C high/low pressure line and remove the
expansion valve carefully.
13.Remove the blower case assembly.
a. Detach the A/C wire harness and connector (arrow)
from the blower case assembly.
b. Detach the evaporator temperature sensor wire
harness and connector (arrow) from the blower case
assembly.
c. Detach the A/C wire harness (arrow) from the blower
case assembly.
RT21310430
RT21310440
RT21310450
RT21310460
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст