Hyundai Santa Fe (2006 year). Manual — part 147
KEYLESS ENTRY AND BURGLAR ALARM
BE -49
7.
AUTO-LOCK TIMER1
CONDITION 1
State
Description
Initial Condition
ARM state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 state
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START the AUTOLOCK TIMER1
CONDITION 2
State
Description
Initial Condition
REARM state
Transition Condition
-
AUTO-LOCK TIMER1 state.
-
TX UNLOCK INPUT.
Operating
-
keep the AUTO-LOCK TIMER1 state
-
CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.
-
CASE2: TX UNLOCK
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times
-
RESTART THE AUTOLOCK TIMER1
CONDITION 3
State
Description
Initial Condition
ARM WAIT state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 state
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER
CONDITION 4
State
Description
Initial Condition
The DISARM state and 4DOOR, T/GATE and HOOD are closed and IGN KEY OUT
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1
CONDITION 5
State
Description
Initial Condition
ALARM state, and 4DOOR, T/GATE and HOOD CLOSE state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
B/ALARM RELAY OFF
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1
BE -50
BODY ELECTRICAL SYSTEM
CONDITION 6
State
Description
Initial Condition
REARM state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
B/ALARM RELAY OFF
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1
8.
AUTO-LOCK TIMER 2
CONDITION 1
State
Description
Initial Condition
AUTO-LOCK TIMER2 state
Transition Condition
-
AUTOLOCK TIMER2 COMPLETION.
-
TX UNLOCK INPUT.
Operating
-
keep the AUTO-LOCK TIMER2 state
-
CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.
-
CASE2: TX UNLOCK
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times
-
RESTART THE AUTOLOCK TIMER1
CONDITION 2
State
Description
Initial Condition
REARM state
Transition Condition
DISARM state AND 4DOOR & T/GATE CLOSE & HOOD OPEN AND IGN KEY OUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2
CONDITION 3
State
Description
Initial Condition
ALARM STATE AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
OFF the HORN, B/ALARM OUTPUT
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2
KEYLESS ENTRY AND BURGLAR ALARM
BE -51
CONDITION 4
State
Description
Initial Condition
PREARM START AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2
9.
PREARM
CONDITION 1
State
Description
Initial Condition
AUTO-LOCK TIMER2 state
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the AUTO LOCK.
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY
LOCK (T/GATE KEY LOCK) INPUT.
Operating
-
Entry into the PREARM state
CONDITION 2
State
Description
Initial Condition
DISARM state & IGN KEY OUT
Transition Condition
-
LOCK SUCCESS after the LOCK ATTEMPT by the TX LOCK in the state
that 4 DOOR or T/GATE or HOOD is opened.
-
LOCK SUCCESS after the LOCK ATTEMPT by the DRIVER KEY LOCK (T/GATE
KEY LOCK) INPUT in the state that 4 DOOR or T/GATE or HOOD is opened.
-
The DOOR is turned to the CLOSE state from the OPEN state in the state
that all doors are locked. But, the HOOD is opened.
Operating
-
Entry into the PREARM state
CONDITION 3
State
Description
Initial Condition
ALARM state & IGN KEY OUT & 4DOOR or T/GATE or HOOD OPEN
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY
LOCK (T/GATE KEY LOCK) INPUT.
Operating
-
Entry into the PREARM state
-
OFF the HORN, HAZARD, B/ALARM OUTPUT
BE -52
BODY ELECTRICAL SYSTEM
10. RESET
CONDITION 1
State
Description
Initial Condition
ALARM, REARM state
Transition Condition
Insert after the BATTERY is withdrawn
Operating
-
The B/ALARM RELAY shall be ON and the HORN ALARM shall be
output three times again (EC SPEC ONCE).
CONDITION 2
State
Description
Initial Condition
ARM state
Transition Condition
Insert after the BATTERY is withdrawn
Operating
-
Keep the ARM state.