Hyundai Santa Fe (2006 year). Manual — part 146
KEYLESS ENTRY AND BURGLAR ALARM
BE -45
CONDITION 5
State
Description
Initial Condition
AUTOLOCK TIMER2 state
Transition Condition
-
When any one of the 4DOOR, HOOD or T/GATE is opened.
-
In case of KEY IN.
-
LOCK FAIL after the LOCK attempt by the AUTO LOCK.
-
LOCK FAIL after the LOCK attempt by the TX LOCK.
-
LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK
(In case of B_MECH_KEY=Enable)
Operating
-
ENTRY INTO THE DISARM STATE
CONDITION 6
State
Description
Initial Condition
ARM state
Transition Condition
-
IGN KEY ON
-
DRIVER KEY UNLOCK(T/GATE KEY UNLOCK) input.
Operating
-
ENTRY INTO THE DISARM STATE
CONDITION 7
State
Description
Initial Condition
REARM state
Transition Condition
-
After 30 seconds in the IGN KEY ON state.
-
LOCK FAIL after the LOCK attempt by the TX LOCK.
-
LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK.
-
When entering DRIVER KEY UNLOCK.
Operating
-
ENTRY INTO THE DISARM STATE
-
B/ALARM RELAY OFF
CONDITION 8
State
Description
Initial Condition
REARM state
Transition Condition
-
In case of TX UNLOCK INPUT in the state that any one of the
4DOOR or T/GATE is opened.
-
In case of KEY IN.
-
In case of the 4DOORor T/GATE or HOOD is closed and at least one door is unlocked.
Operating
-
ENTRY INTO THE DISARM STATE
-
In the case of the TX UNLOCK INPUT, the HAZARD LAMP signal is output
two times with the ON/OFF cycle of 0.5 seconds.
BE -46
BODY ELECTRICAL SYSTEM
3.
ARM
CONDITION 1
State
Description
Initial Condition
ARM state
Transition Condition
When entering TX LOCK
Operating
-
Keep the ARM state
-
The HAZARD LAMP signal is output for 1s once.
CONDITION 2
State
Description
Initial Condition
ARM WAIT state
Transition Condition
After the ARM WAIT TIMER completion
Operating
-
ENTRY INTO THE ARM state
4.
ALARM
CONDITION 1
State
Description
Initial Condition
ARM state
Transition Condition
In case of 4DOOR, T/GATE or HOOD is opened.
Operating
-
ENTRY INTO THE ALARM state
-
The B/ALARM RELAY outputs is ON, and then, inhibit the start.
-
Non-EC area: the Horn alarm shall be output three times with the cycle consisting
of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard
Lamp signal shall also be output as the Horn alarm.)
-
EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once. (At
this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)
CONDITION 2
State
Description
Initial Condition
REARM state
Transition Condition
In case of 4DOOR, T/GATE or HOOD is opened.
Operating
-
ENTRY INTO THE ALARM state
-
Non-EC area: the Horn alarm shall be output three times with the cycle
consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the
Hazard Lamp signal shall also be output as the Horn alarm.)
-
EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once.
(At this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)
KEYLESS ENTRY AND BURGLAR ALARM
BE -47
ARM
STATE
ARM/
REARM
DISARM
4DOOR
HOOD
T/GATE
OPEN
CLOSE
B/ALARM
RELAY
ON
OFF
ON
B/HORN
RELAY
OFF
HAZARD
RELAY
ON
OFF
T2
T1
T1
T1
T3
T3
Non-EC SPECIFICATION
SCMBE6124L
T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec,
T3 : 10 ± 1sec.
ARM
STATE
ARM/
REARM
DISARM
4DOOR
HOOD
T/GATE
OPEN
CLOSE
B/ALARM
RELAY
ON
OFF
ON
B/HORN
RELAY
OFF
HAZARD
RELAY
ON
OFF
T2
T1
EC SPECIFICATION
SCMBE6119L
T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec.
5.
ARM WAIT
CONDITION 1
State
Description
Initial Condition
ARM WAIT state
Transition Condition
When entering TX LOCK
Operating
-
Keep ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
CONDITION 2
State
Description
Initial Condition
DISARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT.
-
In case of 4DOOR, T/GATE, HOOD OPEN>CLOSE with all doors locked.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER
CONDITION 3
State
Description
Initial Condition
ALARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT.
Operating
-
Entry into the ARM WAIT state
-
OFF the HORN, B/ALARM output.
-
The HAZARD LAMP signal shall be output for 1s once
-
Start the ARMWAIT TIMER
BE -48
BODY ELECTRICAL SYSTEM
CONDITION 4
State
Description
Initial Condition
AUTOLOCK TIMER1 state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the AUTOLOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER
KEY LOCK (T/GATE KEY LOCK) INPUT
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER
CONDITION 5
State
Description
Initial Condition
PREARM state
Transition Condition
-
4DOOR, T/GATE and HOOD are closed and all doors are locked.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER
CONDITION 6
State
Description
Initial Condition
REARM state
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK
(T/GATE KEY LOCK) INPUT.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
B/ALARM RLY OFF
-
Start the ARMWAIT TIMER
6.
REARM
CONDITION 1
State
Description
Initial Condition
ALARM state
Transition Condition
4DOOR, T/GATE and HOOD are closed and after the ALARM PATTERN completion
Operating
-
Entry into the REARM state