Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual — part 105
TEST
ACTION
APPLICABILITY
10
Test both sides of fuse #9 for battery voltage.
Is the fuse or circuit open?
All
Yes
→ Replace the fuse or repair the open circuit as necessary.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 11
11
Disconnect the Body Control Module C4 connector.
Connect a jumper wire from the ground to the Passenger Unlock Relay Output circuit
in the C4 connector.
Momentarily connect the jumper wire from a fused B(+) supply to the Passenger Lock
Output circuit in the C4 connector and observe the door locks.
Reverse the jumper wires to drive the motor in the unlock position.
Did the door lock and unlock?
All
Yes
→ Using the wiring diagram/schmatic as a guide, repair the open
Lock or Unlock Relay Output circuits as necessary.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 12
12
Turn the ignition off.
Remove the Body Control Module from the Junction Block.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?
All
Yes
→ Go To 13
No
→ Repair the open Ground circuit through the junction block.
Perform BODY VERIFICATION TEST - VER 1.
13
Turn the ignition off.
Remove the Body Control Module from the Junction Block.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?
All
Yes
→ Go To 14
No
→ Replace the Junction Block.
Perform BODY VERIFICATION TEST - VER 1.
14
If there are no possible causes remaining, view repair
All
Repair
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
405
POWER DOOR LOCKS/RKE
*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ANY SWITCH —
Continued
Symptom:
*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ONE
SWITCH
POSSIBLE CAUSES
FUSED B(+) CIRCUIT OPEN
FUSED B(+) CIRCUIT OPEN
DOOR CYLINDER LOCK SWITCH MUX CIRCUIT SHORT TO GROUND
DOOR SWITCH MUX CIRCUIT SHORT TO GROUND
DOOR CYLINDER LOCK SWITCH MUX CIRCUIT OPEN
DOOR SWITCH MUX CIRCUIT OPEN
POWER DOOR LOCK SWITCH OPEN
DOOR CYLINDER LOCK SWITCH OPEN
BODY CONTROL MODULE - DOOR CYLINDER LOCK SWITCH SENSE OPEN
BODY CONTROL MODULE - DOOR LOCK SWITCH SENSE OPEN
TEST
ACTION
APPLICABILITY
1
Operate the door locks from the door lock switches and the door cylinder lock
switches (if equipped).
Is the problem with a Door Cylinder Lock Switch (VTSS)?
All
Yes
→ Go To 2
No
→ Go To 7
2
Disconnect the inoperative Door Cylinder Lock Switch connector.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?
All
Yes
→ Go To 3
No
→ Repair the Fused B(+) circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
3
Disconnect the inoperative Door Cylinder Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance between ground and the Cylinder Lock Switch Mux circuit.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Door Cylinder Lock Switch Mux circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 4
406
POWER DOOR LOCKS/RKE
TEST
ACTION
APPLICABILITY
4
Disconnect the inoperative Door Cylinder Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance of the Cylinder Lock Switch Mux circuit between the Switch
connector and the BCM C4 connector.
Is the resistance below 5.0 ohms?
All
Yes
→ Go To 5
No
→ Repair the Door Cylinder Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5
Disconnect the inoperative Door Cylinder Lock Switch connector.
Connect a jumper wire between the appropriate Cylinder Lock Switch Mux circuit
and Fused B(+).
With the DRBIII
t in Sensors, read the appropriate Door Arm/Disarm Switch voltage.
Is the voltage above 9.0 volts?
All
Yes
→ Replace the appropriate Door Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 6
6
If there are no possible causes remaining, view repair.
All
Repair
Replace the Body Control Module in accordance with the Service
Information.
Perform BODY VERIFICATION TEST - VER 1.
7
Disconnect the inoperative Door Lock Switch connector.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?
All
Yes
→ Go To 8
No
→ Repair the Fused B(+) circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
8
Disconnect the inoperative Door Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance between ground and the Door Switch Mux circuit.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Door Switch Mux circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 9
9
Disconnect the inoperative Door Lock Switch connector.
Disconnect the Body Control Module C4 connector.
Measure the resistance of the Door Switch Mux circuit between the Door Lock Switch
connector and the BCM C4 connector.
Is the resistance below 5.0 ohms?
All
Yes
→ Go To 10
No
→ Repair the Door Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
407
POWER DOOR LOCKS/RKE
*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ONE SWITCH —
Continued
TEST
ACTION
APPLICABILITY
10
Disconnect the inoperative Door Lock Switch connector.
Connect a jumper wire between the Door Switch Mux circuit and Fused B(+).
With the DRBIII
t, read the Door Lock Sw Volts status.
Is the voltage above 9.0 volts?
All
Yes
→ Replace the Power Door Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 11
11
If there are no possible causes remaining, view repair.
All
Repair
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
408