Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual — part 105

TEST

ACTION

APPLICABILITY

10

Test both sides of fuse #9 for battery voltage.
Is the fuse or circuit open?

All

Yes

→ Replace the fuse or repair the open circuit as necessary.

Perform BODY VERIFICATION TEST - VER 1.

No

Go To 11

11

Disconnect the Body Control Module C4 connector.
Connect a jumper wire from the ground to the Passenger Unlock Relay Output circuit
in the C4 connector.
Momentarily connect the jumper wire from a fused B(+) supply to the Passenger Lock
Output circuit in the C4 connector and observe the door locks.
Reverse the jumper wires to drive the motor in the unlock position.
Did the door lock and unlock?

All

Yes

→ Using the wiring diagram/schmatic as a guide, repair the open

Lock or Unlock Relay Output circuits as necessary.
Perform BODY VERIFICATION TEST - VER 1.

No

Go To 12

12

Turn the ignition off.
Remove the Body Control Module from the Junction Block.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?

All

Yes

Go To 13

No

→ Repair the open Ground circuit through the junction block.

Perform BODY VERIFICATION TEST - VER 1.

13

Turn the ignition off.
Remove the Body Control Module from the Junction Block.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?

All

Yes

Go To 14

No

→ Replace the Junction Block.

Perform BODY VERIFICATION TEST - VER 1.

14

If there are no possible causes remaining, view repair

All

Repair

Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.

405

POWER DOOR LOCKS/RKE

*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ANY SWITCH —

Continued

Symptom:

*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ONE
SWITCH

POSSIBLE CAUSES

FUSED B(+) CIRCUIT OPEN

FUSED B(+) CIRCUIT OPEN

DOOR CYLINDER LOCK SWITCH MUX CIRCUIT SHORT TO GROUND

DOOR SWITCH MUX CIRCUIT SHORT TO GROUND

DOOR CYLINDER LOCK SWITCH MUX CIRCUIT OPEN

DOOR SWITCH MUX CIRCUIT OPEN

POWER DOOR LOCK SWITCH OPEN

DOOR CYLINDER LOCK SWITCH OPEN

BODY CONTROL MODULE - DOOR CYLINDER LOCK SWITCH SENSE OPEN

BODY CONTROL MODULE - DOOR LOCK SWITCH SENSE OPEN

TEST

ACTION

APPLICABILITY

1

Operate the door locks from the door lock switches and the door cylinder lock
switches (if equipped).
Is the problem with a Door Cylinder Lock Switch (VTSS)?

All

Yes

Go To 2

No

Go To 7

2

Disconnect the inoperative Door Cylinder Lock Switch connector.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?

All

Yes

Go To 3

No

→ Repair the Fused B(+) circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the inoperative Door Cylinder Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance between ground and the Cylinder Lock Switch Mux circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Cylinder Lock Switch Mux circuit for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

Go To 4

406

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

Disconnect the inoperative Door Cylinder Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance of the Cylinder Lock Switch Mux circuit between the Switch
connector and the BCM C4 connector.
Is the resistance below 5.0 ohms?

All

Yes

Go To 5

No

→ Repair the Door Cylinder Lock Switch Mux circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

5

Disconnect the inoperative Door Cylinder Lock Switch connector.
Connect a jumper wire between the appropriate Cylinder Lock Switch Mux circuit
and Fused B(+).
With the DRBIII

t in Sensors, read the appropriate Door Arm/Disarm Switch voltage.

Is the voltage above 9.0 volts?

All

Yes

→ Replace the appropriate Door Cylinder Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

No

Go To 6

6

If there are no possible causes remaining, view repair.

All

Repair

Replace the Body Control Module in accordance with the Service
Information.
Perform BODY VERIFICATION TEST - VER 1.

7

Disconnect the inoperative Door Lock Switch connector.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.0 volts?

All

Yes

Go To 8

No

→ Repair the Fused B(+) circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

8

Disconnect the inoperative Door Lock Switch connector.
Disconnect the BCM C4 connector.
Measure the resistance between ground and the Door Switch Mux circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Switch Mux circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

Go To 9

9

Disconnect the inoperative Door Lock Switch connector.
Disconnect the Body Control Module C4 connector.
Measure the resistance of the Door Switch Mux circuit between the Door Lock Switch
connector and the BCM C4 connector.
Is the resistance below 5.0 ohms?

All

Yes

Go To 10

No

→ Repair the Door Switch Mux circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

407

POWER DOOR LOCKS/RKE

*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ONE SWITCH —

Continued

TEST

ACTION

APPLICABILITY

10

Disconnect the inoperative Door Lock Switch connector.
Connect a jumper wire between the Door Switch Mux circuit and Fused B(+).
With the DRBIII

t, read the Door Lock Sw Volts status.

Is the voltage above 9.0 volts?

All

Yes

→ Replace the Power Door Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

No

Go To 11

11

If there are no possible causes remaining, view repair.

All

Repair

Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.

408

POWER DOOR LOCKS/RKE

*ALL DOORS FAILING TO LOCK AND UNLOCK FROM ONE SWITCH —

Continued

Была ли эта страница вам полезна?
Да!Нет
7 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности