Chrysler 300/300 Touring/300C, Dodge Magnum. Manual — part 1852

12. Remove two previously loosened pump mounting

bolts (1) and remove power steering pump (2)
from engine.

NOTE: The drive pulley is not serviced separately
from the power steering pump.

INSTALLATION

2.7L/3.5L

1. Align pump (3) with mounting holes on engine

bracket (2).

2. Install three pump mounting bolts (1) through

access holes in pulley and engine bracket. Tighten
bolts to 28 N·m (21 ft. lbs.) torque.

19 - 226

PUMP

LX

NOTE: Always use a NEW O-ring on the end of the
pressure hose.

3. Lubricate NEW O-ring on end of pressure hose

with clean power steering fluid.

4. Install pressure hose (2) to pump (1). Tighten pres-

sure hose tube nut to 47 N·m (35 ft. lbs.) torque.

5. Install supply hose (3) on pump. Install clamp (2)

securing hose in place.

6. Install serpentine drive belt. (Refer to 7 - COOL-

ING/ACCESSORY DRIVE/DRIVE BELTS - INSTAL-
LATION)

7. Install air cleaner housing and inlet tube. (Refer to

9 - ENGINE/AIR INTAKE SYSTEM/AIR CLEANER
HOUSING - INSTALLATION)

8. Connect battery negative cable (2) to battery post.

It is important that this is performed properly. (Refer
to 8 - ELECTRICAL/BATTERY SYSTEM - STAN-
DARD PROCEDURE)

9. Fill pump reservoir with fluid and perform pump ini-

tial operation procedure. (Refer to 19 - STEERING/
PUMP - STANDARD PROCEDURE)

LX

PUMP

19 - 227

5.7L/6.1L

1. Align pump (1) with mounting holes on engine.

2. Install three pump mounting bolts (2) through

access holes in pulley. Tighten bolts to 28 N·m (21
ft. lbs.) torque.

NOTE: Always use a NEW O-ring on the end of the
pressure hose.

3. Lubricate NEW O-ring on end of pressure hose

with clean power steering fluid.

4. Install pressure hose (2) to pump (1). Tighten pres-

sure hose tube nut to 47 N·m (35 ft. lbs.) torque.

19 - 228

PUMP

LX

5. Install supply hose (3) on pump (1). Install clamp

securing hose in place.

6. Install serpentine drive belt. (Refer to 7 - COOL-

ING/ACCESSORY DRIVE/DRIVE BELTS - INSTAL-
LATION)

7. Install air cleaner housing and inlet tube. (Refer to

9 - ENGINE/AIR INTAKE SYSTEM/AIR CLEANER
HOUSING - INSTALLATION)

8. Connect battery negative cable (2) to battery post.

It is important that this is performed properly. (Refer
to 8 - ELECTRICAL/BATTERY SYSTEM - STAN-
DARD PROCEDURE)

9. Fill pump reservoir with fluid and perform pump ini-

tial operation procedure. (Refer to 19 - STEERING/
PUMP - STANDARD PROCEDURE)

LX

PUMP

19 - 229