SsangYong Musso. Manual — part 534
7B/C-16 MANUAL & SEMIAUTO-HVAC
1 Main Condenser Fan
2 Auxiliary Condenser Fan
3 Bolt
4 Condenser
Gasoline Engine
MANUAL & SEMIAUTO-HVAC 7B/C-17
Removal & Installation Procedure
1. Disconnect the inlet and outlet pipes of condenser.
Notice
Before disconnection, evacuate the refrigerant from the
system.
2. Remove the mounting bolts (4bolts) and condenser
assembly.
3. Remove the main condenser fan from condenser.
4. Installation should follow the removal procedure in the
reverse order.
7B/C-18 MANUAL & SEMIAUTO-HVAC
RECEIVER DRIER
Diesel Engine
1 Condenser
2 Receiver Drier
3 Bolt . . . . . . . . . . . . . . . 4-6 Nm
4 Bolt . . . . . . . . . . . . . . .. 5-8 Nm
5 Bracket
MANUAL & SEMIAUTO-HVAC 7B/C-19
Removal & Installation Procedure
1. Disconnect the negative(-) terminal from the battery.
2. Discharge refrigerant from the system.
Notice
By connecting a manifold gauge connection hose to High/
Low pressure line, discharge the refrigerant.
3. Disconnect the inlet and outlet pipes of receiver drier.
Notice
When installing, check the O-ring and apply the compressor
oil.
Installation Notice
4. Remove the bracket bolt and then remove the receiver drier.
Installation Notice
Tightening Torque
4 - 6 Nm
5. Installation should follow the removal procedure in the
reverse order.
Tightening Torque
5 - 8 Nm
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.