Isuzu D-Max / Isuzu Rodeo (TFR/TFS). Manual — part 583

ENGINE COOLING 6B – 3

GENERAL DESCRIPTION

COOLANT FLOW





























6B – 4 ENGINE COOLING





























4JA1TC

ENGINE COOLING 6B – 5




























C06L200009

The engine cooling system consists of the radiator, the water pump, the cooling fan, and the thermostat.
To quickly increase cold engine coolant temperature for smooth engine operation, the coolant is circulated by the
water pump and thermostat through the bypass hose and back to the cylinder body. The coolant does not circulate
through the radiator.
When the coolant temperature reaches specified value, the thermostat will begin to open and a gradually increasing
amount of coolant will circulate through the radiator.
The thermostat will be fully open when the coolant temperature reaches specified value. All of the coolant is now
circulating through the radiator for effective engine cooling.

4JH1TC

6B – 6 ENGINE COOLING

WATER PUMP























A centrifugal type water pump forcefully circulates the coolant through the cooling system.
The water pump is not disassembled type.

THERMOSTAT
















A wax pellet type thermostat is used.
The jiggle valve accelerates engine warm-up.