Nissan Juke (2014 year). Service Repair Manual — part 53
DOOR LOCK ACTUATOR
DLK-73
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
3.
CHECK BCM OUTPUT SIGNAL
1.
Connect BCM connector.
2.
Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
PASSENGER SIDE
PASSENGER SIDE : Component Function Check
INFOID:0000000009753973
1.
CHECK FUNCTION
1.
Select “DOOR LOCK” of “BCM” using CONSULT.
2.
Select “DOOR LOCK” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-72, "DRIVER SIDE : Diagnosis Procedure"
PASSENGER SIDE : Diagnosis Procedure
INFOID:0000000009753974
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect front door lock assembly (passenger side) connector.
3.
Check voltage between front door lock assembly (passenger side) harness connector and ground.
Is the inspection result normal?
YES
>> Replace front door lock assembly (passenger side).
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1.
Disconnect BCM connector and all door lock assembly connector.
2.
Check continuity between BCM harness connector and front door lock assembly (passenger side) har-
ness connector.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M69
66
Ground
Door lock and unlock switch
Unlock
12 V
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
(+)
(–)
Condition
Voltage
(Approx.)
Front door lock assembly
(passenger side)
Connector
Terminal
D17
6
Ground
Door lock and unlock switch
Unlock
12 V
5
Lock
Revision: 2013 October
2014 JUKE
DLK-74
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK ACTUATOR
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1.
Connect BCM connector.
2.
Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
REAR LH
REAR LH : Component Function Check
INFOID:0000000009753975
1.
CHECK FUNCTION
1.
Select “DOOR LOCK” of “BCM” using CONSULT.
2.
Select “DOOR LOCK” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-72, "DRIVER SIDE : Diagnosis Procedure"
REAR LH : Diagnosis Procedure
INFOID:0000000009753976
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect rear door lock assembly LH connector.
3.
Check voltage between rear door lock assembly LH harness connector and ground.
BCM
Front door lock assembly (passenger side)
Continuity
Connector
Terminal
Connector
Terminal
M69
59
D17
6
Existed
65
5
BCM
Ground
Continuity
Connector
Terminal
M69
59
Not existed
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M69
59
Ground
Door lock and unlock switch
Unlock
12 V
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
Revision: 2013 October
2014 JUKE
DOOR LOCK ACTUATOR
DLK-75
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace rear door lock assembly LH.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1.
Disconnect BCM connector and all door lock assembly connector.
2.
Check continuity between BCM harness connector and rear door lock assembly LH harness connector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1.
Connect BCM connector.
2.
Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
REAR RH
REAR RH : Component Function Check
INFOID:0000000009753977
1.
CHECK FUNCTION
1.
Select “DOOR LOCK” of “BCM” using CONSULT.
2.
Select “DOOR LOCK” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock assembly LH
Connector
Terminal
D65
2
Ground
Door lock and unlock switch
Unlock
12 V
1
Lock
BCM
Rear door lock assembly LH
Continuity
Connector
Terminal
Connector
Terminal
B10
55
D65
2
Existed
M69
65
1
BCM
Ground
Continuity
Connector
Terminal
B10
55
Not existed
M69
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
B10
55
Ground
Door lock and unlock switch
Unlock
12 V
M69
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
Revision: 2013 October
2014 JUKE
DLK-76
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK ACTUATOR
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-72, "DRIVER SIDE : Diagnosis Procedure"
REAR RH : Diagnosis Procedure
INFOID:0000000009753978
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect rear door lock assembly RH connector.
3.
Check voltage between rear door lock assembly RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace rear door lock assembly RH.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1.
Disconnect BCM connector and all door lock assembly connector.
2.
Check continuity between BCM harness connector and rear door lock assembly RH harness connector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1.
Connect BCM connector.
2.
Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock assembly RH
Connector
Terminal
D45
6
Ground
Door lock and unlock switch
Unlock
12 V
5
Lock
BCM
Rear door lock assembly RH
Continuity
Connector
Terminal
Connector
Terminal
B10
55
D45
6
Existed
M69
65
5
BCM
Ground
Continuity
Connector
Terminal
B10
55
Not existed
M69
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
B10
55
Ground
Door lock and unlock switch
Unlock
12 V
M69
65
Lock
Revision: 2013 October
2014 JUKE
DOOR LOCK AND UNLOCK SWITCH
DLK-77
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR LOCK AND UNLOCK SWITCH
Component Function Check
INFOID:0000000009753979
1.
CHECK FUNCTION
1.
Select “DOOR LOCK” of “BCM” using CONSULT.
2.
Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock and unlock switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753980
1.
CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect power window main switch connector.
3.
Check signal between power window main switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK AND UNLOCK SWITCH CIRCUIT
1.
Disconnect BCM connector and power window main switch connector.
2.
Check continuity between BCM harness connector and power window main switch harness connector.
3.
Check continuity between BCM harness connector and ground.
Monitor item
Condition
Status
CDL LOCK SW
Door lock and unlock switch
Lock
ON
Unlock
OFF
CDL UNLOCK SW
Lock
OFF
Unlock
ON
(+)
(–)
Signal
(Reference value)
Power window main switch
Connector
Terminal
D35
3
Ground
1.0 - 1.5 V
15
JPMIA0012GB
BCM
Power window main switch
Continuity
Connector
Terminal
Connector
Terminal
M68
12
D35
3
Existed
13
15
Revision: 2013 October
2014 JUKE
DLK-78
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK AND UNLOCK SWITCH
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK DOOR LOCK AND UNLOCK SWITCH GROUND
Check continuity between power window main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR LOCK AND UNLOCK SWITCH
DLK-78, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace power window main switch. Refer to
PWC-55, "Removal and Installation"
5.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000009753981
1.
CHECK DOOR LOCK AND UNLOCK SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect power window main switch connector.
3.
Check continuity between power window main switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace power window main switch.
BCM
Ground
Continuity
Connector
Terminal
M68
12
Not existed
13
Power window main switch
Ground
Continuity
Connector
Terminal
D35
1
Existed
Power window main switch
Condition
Continuity
Terminal
3
1
Door lock and unlock
switch
LOCK
Existed
UNLOCK
Not existed
15
LOCK
Not existed
UNLOCK
Existed
Revision: 2013 October
2014 JUKE
DOOR REQUEST SWITCH
DLK-79
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR REQUEST SWITCH
Component Function Check
INFOID:0000000009753982
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “REQ SW-DR”, “REQ SW-AS” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Front door request switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753983
1.
CHECK DOOR REQUEST SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect malfunctioning front door request switch connector.
3.
Check voltage between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR REQUEST SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between malfunctioning front door request switch harness connector and BCM harness
connector.
3.
Check continuity between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
NO
>> Repair or replace harness.
Monitor item
Condition
Status
REQ SW -DR
Driver side door request switch
Pressed
ON
Released
OFF
REQ SW -AS
Passenger side door request switch
Pressed
ON
Released
OFF
(+)
(–)
Voltage
(Approx.)
Front door request switch
Connector
Terminal
Driver side
D34
2
Ground
12 V
Passenger side
D15
1
Front door request switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
Driver side
D34
2
M70
75
Existed
Passenger side
D15
1
100
Front door request switch
Ground
Continuity
Connector
Terminal
Driver side
D34
2
Not existed
Passenger side
D15
1
Revision: 2013 October
2014 JUKE
DLK-80
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR REQUEST SWITCH
3.
CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR REQUEST SWITCH
DLK-80, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace malfunctioning front door request switch.
5.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000009753984
1.
CHECK DOOR REQUEST SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect malfunctioning front door request switch connector.
3.
Check continuity between malfunctioning front door request switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace malfunctioning front door request switch.
Front door request switch
Ground
Continuity
Connector
Terminal
Driver side
D34
1
Existed
Passenger side
D15
2
Front door request switch
Condition
Continuity
Terminal
1
2
Door request switch
Pressed
Existed
Released
Not existed
Revision: 2013 October
2014 JUKE
DOOR SWITCH
DLK-81
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR SWITCH
Component Function Check
INFOID:0000000009753985
1.
CHECK FUNCTION
1.
Select “DOOR LOCK” of “BCM” using CONSULT.
2.
Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, “DOOR SW-BK” in “DATA
MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753986
1.
CHECK DOOR SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect malfunctioning door switch connector.
3.
Check signal between malfunctioning door switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES-1 >> Back door: GO TO 3.
YES-2 >> Other door: GO TO 4.
NO
>> GO TO 2.
2.
CHECK DOOR SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between door switch harness connector and BCM harness connector.
Monitor item
Condition
Status
DOOR SW-DR
Driver side door
Open
On
Closed
Off
DOOR SW-AS
Passenger side door
Open
On
Closed
Off
DOOR SW-RL
Rear door LH
Open
On
Closed
Off
DOOR SW-RR
Rear door RH
Open
On
Closed
Off
DOOR SW-BK
Back door
Open
On
Closed
Off
(+)
(–)
Signal
(Reference value)
Door switch
Connector
Terminal
Driver side
B48
2
Ground
7.0 - 8.0 V
Passenger side
B49
Rear LH
B71
Rear RH
B53
Back door
D106
3
PKIB4960J
Revision: 2013 October
2014 JUKE
DLK-82
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR SWITCH
3.
Check continuity between door switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK BACK DOOR LOCK ASSEMBLY CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR SWITCH
DLK-82, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace malfunctioning door switch.
5.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000009753987
1.
CHECK DOOR SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect malfunctioning door switch connector.
3.
Check continuity between door switch terminals.
Door switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
Driver side
B48
2
B10
47
Existed
Passenger side
B49
45
Rear LH
B71
48
Rear RH
B53
46
Back door
D106
3
43
Door switch
Ground
Continuity
Connector
Terminal
Driver side
B48
2
Not existed
Passenger side
B49
Rear LH
B71
Rear RH
B53
Back door
D106
3
Back door switch
Ground
Continuity
Connector
Terminal
D106
4
Existed
Revision: 2013 October
2014 JUKE
DOOR SWITCH
DLK-83
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace malfunction door switch.
Door switch
Condition
Continuity
Terminal
Driver side
2
Ground part of door
switch
Door switch
Pressed
Existed
Released
Not existed
Passenger side
Pressed
Existed
Released
Not existed
Rear LH
Pressed
Existed
Released
Not existed
Rear RH
Pressed
Existed
Released
Not existed
Back door
3
4
Back door lock as-
sembly
Lock
Existed
Unlock
Not existed
Revision: 2013 October
2014 JUKE
DLK-84
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
HAZARD FUNCTION
HAZARD FUNCTION
Component Function Check
INFOID:0000000009753988
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “FLASHER” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Hazard warning lamp circuit is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753989
1.
CHECK HAZARD SWITCH CIRCUIT
EXL-79, "Component Function Check"
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Monitor item
Status
FLASHER
LH
Front turn signal lamp LH
Turns ON
RH
Front turn signal lamp RH
Turns ON
OFF
Front turn signal lamp
Turns OFF
Revision: 2013 October
2014 JUKE
INTELLIGENT KEY BATTERY
DLK-85
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
INTELLIGENT KEY BATTERY
Component Inspection
INFOID:0000000009753990
1.
CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300
Ω
) so that the
current value becomes about 10 mA.
Is the measurement value within the specification?
YES
>> INSPECTION END
NO
>> Replace Intelligent Key battery.
Standard
: Approx. 2.5 - 3.0 V
OCC0607D
Revision: 2013 October
2014 JUKE
DLK-86
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
INTELLIGENT KEY WARNING BUZZER
INTELLIGENT KEY WARNING BUZZER
Component Function Check
INFOID:0000000009753991
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “OUTSIDE BUZZER” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Intelligent Key warning buzzer is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753992
1.
CHECK FUSE
1.
Turn ignition switch OFF.
2.
Check 10 A fuse, [No. 13, located in fuse block (J/B)].
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.
2.
CHECK INTELLIGENT KEY WARNING BUZZER POWER SUPPLY CIRCUIT
1.
Disconnect Intelligent Key warning buzzer connector.
2.
Check voltage between Intelligent Key warning buzzer harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK INTELLIGENT KEY WARNING BUZZER CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and Intelligent Key warning buzzer harness connector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
Monitor item
Status
OUTSIDE BUZZER
ON
Outside warning buzzer
Buzzer sounds
OFF
Buzzer does not sound
(+)
(–)
Voltage
(Approx.)
Intelligent Key warning buzzer
Connector
Terminal
E25
1
Ground
Battery voltage
BCM
Intelligent Key warning buzzer
Continuity
Connector
Terminal
Connector
Terminal
M70
93
E25
3
Existed
BCM
Ground
Continuity
Connector
Terminal
M70
93
Not existed
Revision: 2013 October
2014 JUKE
INTELLIGENT KEY WARNING BUZZER
DLK-87
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
4.
CHECK INTELLIGENT KEY WARNING BUZZER
DLK-87, "Component Inspection"
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-90, "Removal and Installation"
NO
>> Replace Intelligent Key warning buzzer.
Component Inspection
INFOID:0000000009753993
1.
CHECK INTELLIGENT KEY WARNING BUZZER
1.
Turn ignition switch OFF.
2.
Disconnect Intelligent Key warning buzzer connector.
3.
Connect battery power supply directly to Intelligent Key warning buzzer terminals and check the opera-
tion.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace Intelligent Key warning buzzer.
Intelligent Key warning buzzer
Operation
Terminal
(+)
(
−
)
1
3
Buzzer sounds
Revision: 2013 October
2014 JUKE
DLK-88
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
KEY WARNING LAMP
KEY WARNING LAMP
Component Function Check
INFOID:0000000009753994
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “INDICATOR” in “ACTIVE TEST” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Key warning lamp is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000009753995
1.
CHECK KEY WARNING LAMP
MWI-20, "On Board Diagnosis Function"
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK INTERMITTENT INCIDENT
GI-46, "Intermittent Incident"
>> INSPECTION END
Monitor item
Status
INDICATOR
KEY ON
Key warning lamp
Turns ON
KEY IND
Blinks
OFF
Turns OFF
Revision: 2013 October