Juke F15 (2012 year). Service Repair Manual — part 170
P0226 APP SENSOR
EC-929
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
DETECT MALFUNCTIONING PART
• Harness connectors M77, E105 (RHD models)
• Harness connectors M95, M202 (RHD models)
• Harness for open or short between ECM and accelerator pedal position sensor
>> Repair open circuit or short to ground or short to power in harness or connector.
6.
CHECK ACCELERATOR PEDAL POSITION SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between accelerator pedal position sensor harness connector and ECM harness
connector.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> GO TO 7.
7.
DETECT MALFUNCTIONING PART
• Harness connectors M77, E105 (RHD models)
• Harness connectors M95, M202 (RHD models)
• Harness for open or short between ECM and accelerator pedal position sensor
>> Repair open circuit or short to ground or short to power in harness or connector.
8.
CHECK ACCELERATOR PEDAL POSITION SENSOR
EC-929, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Replace accelerator pedal position sensor.
9.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
>> INSPECTION END
Component Inspection
INFOID:0000000006496612
1.
CHECK ACCELERATOR PEDAL POSITION SENSOR
1.
Turn ignition switch OFF.
2.
Disconnect accelerator pedal position sensor harness connector.
3.
Check resistance between accelerator pedal position sensor as follows.
Is the inspection result normal?
YES
>> INSPECTION END
Accelerator pedal position sensor
ECM
Continuity
Sensor
Connector
Terminal
Connector
Terminal
1
E110 (LHD models)
M206 (RHD models)
3
E32
158
Existed
2
6
151
Sensor
Terminals
Resistance
1
2 and 4
1.7
±
0.9 K
Ω
2
1 and 5
2.85
±
2.05 K
Ω
EC-930
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0226 APP SENSOR
NO
>> Replace accelerator pedal position sensor.
P0263, P0266, P0269, P0272 FUEL INJECTOR
EC-931
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0263, P0266, P0269, P0272 FUEL INJECTOR
DTC Logic
INFOID:0000000006496613
DTC DETECTION LOGIC
NOTE:
Check injector code when the above DTC is indicated. If the code is normal, replace injector showing an appli-
cable code. If the code is not normal, load injector codes and initialize the injector learning.
DTC No.
Trouble diagnosis name
Possible cause
P0263
NO. 1 cylinder fuel injector performance
• Fuel injector
P0266
NO. 2 cylinder fuel injector performance
P0269
NO. 3 cylinder fuel injector performance
P0272
NO. 4 cylinder fuel injector performance
EC-932
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0335 CKP SENSOR (POS)
P0335 CKP SENSOR (POS)
DTC Logic
INFOID:0000000006496614
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000006496615
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground inspection in
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK CKP SENSOR (POS) GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect crankshaft position (CKP) sensor (POS) harness connector.
3.
Disconnect ECM harness connector.
4.
Check the continuity between CKP sensor (POS) harness connector and ECM harness connector.
5.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK CKP SENSOR (POS) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between CKP sensor (POS) harness connector and ECM harness connector.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK CKP SENSOR (POS)
EC-933, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace crankshaft position sensor (POS).
DTC No.
Trouble diagnosis name
Possible cause
P0335
CRANKSHAFT POSITION SENSOR (POS) CIRCUIT
• 1.DEF: Signal incoherence
• 2.DEF: No signal
• 3.DEF: Signal interference
• 4.DEF: Number of teeth incorrect.
• 5.DEF: Plausibility.
• CO: Open circuit
• Harness or connectors
(The sensor circuit is open or shorted.)
• Crankshaft position sensor (POS)
• Signal plate
CKP sensor (POS)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F73
2
F57
114
Existed
CKP sensor (POS)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F73
1
F57
113
Existed
P0335 CKP SENSOR (POS)
EC-933
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
5.
CHECK GEAR TOOTH
Visually check for chipping flywheel gear tooth.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace signal plate.
6.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
>> INSPECTION END
Component Inspection
INFOID:0000000006496616
1.
CHECK CKP SENSOR (POS)
1.
Turn ignition switch OFF.
2.
Disconnect CKP sensor (POS) harness connector.
3.
Check resistance between CKP sensor (POS) terminals as follows.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace CKP sensor.
Terminals
Resistance
1 and 2
520 - 860
Ω
EC-934
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0340 CMP SENSOR (PHASE)
P0340 CMP SENSOR (PHASE)
DTC Logic
INFOID:0000000006496617
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000006496618
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground inspection in
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK CMP SENSOR (PHASE) POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect camshaft position (CMP) sensor (PHASE) harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between CMP sensor (PHASE) harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK CMP SENSOR (PHASE) GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between CMP sensor (PHASE) harness connector and ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between CMP sensor (PHASE) harness connector and ECM harness connector.
DTC No.
Trouble diagnosis name
Possible cause
P0340
CAMSHAFT POSITION SENSOR (PHASE) CIRCUIT
• 6.DEF: Camshaft signal incoherence
• 7.DEF: No signal
• 9.DEF: Signal with interference
• 10.DEF: Plausibility
• Harness or connectors
(The sensor circuit is open or shorted.)
• Camshaft position sensor (PHASE)
• Timing belt
• Signal plate
CMP sensor (PHASE)
Ground
Voltage
Connector
Terminal
F70
1
Ground
Battery voltage
CMP sensor (PHASE)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F70
2
F57
99
Existed
CMP sensor (PHASE)
ECM
Continuity
Connector
Terminal
Connector
Terminal
F70
3
F57
126
Existed
P0340 CMP SENSOR (PHASE)
EC-935
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK CMP SENSOR (PHASE)
EC-935, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace camshaft position sensor (PHASE).
6.
CHECK SIGNAL PLATE
Visually check for chipping signal plate gear tooth of CMP sensor.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair or replace sprocket.
7.
CHECK TIMING BELT
EM-302, "Removal and Installation"
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Replace timing belt.
8.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
>> INSPECTION END
Component Inspection
INFOID:0000000006496619
1.
CHECK CMP SENSOR (PHASE)
1.
Reconnect all harness connectors disconnected.
2.
Start engine and warm it up to normal operating temperature.
3.
Measure the voltage signal between ECM harness connector and ground under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace CMP sensor.
+
-
Condition
Voltage
Connector
Terminal
Connector
Terminal
F57
126
(CMP sensor
signal)
E32
160
[Engine is running]
• Warm-up condition
• Idle speed
NOTE:
The pulse cycle
changes depending on
rpm at idle.
[Engine is running]
• Warm-up condition
• Engine speed: 2,000
rpm
JSBIA0140GB
JSBIA0141GB
EC-936
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0380 GLOW RELAY
P0380 GLOW RELAY
DTC Logic
INFOID:0000000006496620
DTC DETECTION LOGIC
NOTE:
If DTC P0380 is displayed with DTC P0560 or P0657, first perform trouble diagnosis for DTC P0560 or P0657.
Refer to
(DTC P0657).
Diagnosis Procedure
INFOID:0000000006496621
1.
CHECK GLOW RELAY POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect glow relay harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between glow relay connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• 100 A fusible link (letter B)
• Harness for open and short between glow relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK GLOW RELAY INPUT CIRCUIT FOR OPEN AND SHORT-I
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between glow relay harness connector and ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK GLOW RELAY OUTPUT CIRCUIT FOR OPEN AND SHORT-II
1.
Check the continuity between glow relay harness connector and ECM harness connector.
DTC No.
Trouble diagnosis name
Possible cause
P0380
GLOW PLUG DIAGNOSTIC CONNECTION
• CO: Open circuit
• CC.0: Short circuit to earth.
• CC.1: Short circuit to +12V
• 1.DEF: Fault alerted via the control unit
• Harness or connectors
(The glow relay circuit is open or shorted.)
• Glow relay
• Glow plug
Glow relay
Ground
Voltage
Connector
Terminal
F16
4
Ground
Battery voltage
Glow relay
ECM
Continuity
Connector
Terminal
Connector
Terminal
F16
3
F57
122
Existed
P0380 GLOW RELAY
EC-937
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
Is the inspection result normal?
YES
>> Replace glow relay.
NO
>> Repair or replace.
Glow relay
ECM
Continuity
Connector
Terminal
Connector
Terminal
F16
8
F57
110
Existed
EC-938
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0402 EGR VOLUME CONTROL VALVE
P0402 EGR VOLUME CONTROL VALVE
DTC Logic
INFOID:0000000006496622
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000006496623
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground inspection in
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK EGR VOLUME CONTROL VALVE INSTALLATION
Check that EGR volume control valve is installed properly.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Install EGR volume control valve properly.
3.
CHECK EGR VOLUME CONTROL VALVE CONTROL MOTOR CIRCUIT
1.
Check harness continuity between the following terminals.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK EGR VOLUME CONTROL VALVE VISUALLY
1.
Remove the EGR volume control valve
2.
Check if foreign matter is caught between the EGR volume control valve and the housing.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Remove the foreign matter and clean the EGR volume control valve.
5.
CHECK EGR PASSAGE
Check the following for clogging and cracks.
• EGR tube
• EGR hose
• EGR cooler
Is the inspection result normal?
DTC No.
Trouble diagnosis name
Possible cause
P0402
EGR VOLUME CONTROL
• Harness or connectors
(The EGR volume control valve circuit is open
or shorted.)
• EGR volume control valve
EGR volume control valve
ECM
Continuity
Connector
Terminal
Connector
Terminal
F88
2
F58
14
Existed
13
Not existed
6
14
Not existed
13
Existed
P0402 EGR VOLUME CONTROL VALVE
EC-939
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
YES
>> GO TO 6.
NO
>> Repair or replace EGR passage.
6.
CHECK EGR VOLUME CONTROL VALVE
EC-939, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 8.
7.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Repair or replace.
8.
REPLACE EGR VOLUME CONTROL VALVE
1.
Replace the EGR volume control valve.
2.
>> INSPECTIO END
Component Inspection
INFOID:0000000006496624
1.
CHECK EGR VOLUME CONTROL VALVE CONTROL MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect EGR volume control valve harness connector.
3.
Check resistance between EGR volume control valve terminals as follows.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
REPLACE EGR VOLUME CONTROL VALVE
1.
Replace the EGR volume control valve.
2.
>> INSPECTIO END
Terminals
Resistance
2 and 6
2.3
Ω
[at 25
°
C (77
°
F)]
EC-940
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0403 EGR VOLUME CONTROL VALVE
P0403 EGR VOLUME CONTROL VALVE
DTC Logic
INFOID:0000000006496625
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000006496626
1.
CHECK EGR VOLUME CONTROL VALVE CONTROL CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect EGR volume control valve harness connector and ECM harness connector.
3.
Check the continuity between EGR volume control valve terminal harness connector and ECM harness
connector.
4.
Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 2.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
2.
CHECK EGR VOLUME CONTROL VALVE
EC-941, "Component Inspection"
OK or NG
OK
>> GO TO 3.
NG
>> Replace EGR volume control valve.
3.
CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR
EC-941, "Component Inspection"
OK or NG
OK
>> GO TO 4.
NG
>> Replace EGR volume control valve.
4.
CHECK EGR PASSAGE
Check the following for clogging and cracks.
• EGR tube
• EGR hose
• EGR cooler
OK or NG
OK
>> GO TO 5.
NG
>> Repair or replace EGR passage.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
DTC No.
Trouble diagnosis name
Possible cause
P0403
EGR VOLUME CONTROL VALVE CIRCUIT
• 1.DEF: Internal electronic fault
• 2.DEF: Operation temperature too high.
• Harness or connectors
(The EGR volume control valve circuit is open
or shorted.)
• EGR volume control valve
EGR volume control valve terminal
ECM
Continuity
Connector
Terminal
Connector
Terminal
F88
1
F58
32
Existed
2
14
3
59
5
38
6
13
P0403 EGR VOLUME CONTROL VALVE
EC-941
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
>> INSPECTION END
Component Inspection
INFOID:0000000006496627
EGR VOLUME CONTROL VALVE
1.
Disconnect EGR volume control valve harness connector.
2.
Check resistance EGR volume control valve harness connector.
If NG, replace EGR volume control valve. Refer to
.
EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR
1.
Disconnect EGR volume control valve harness connector.
2.
Check continuity EGR volume control valve harness connector.
If NG, replace EGR volume control valve. Refer to
.
EGR volume control valve
Resistance
Connector
Terminal
Connector
Terminal
F88
2
F88
6
2.3
Ω
[at 25
°
C (77
°
F)]
EGR volume control valve
Continuity
Connector
Terminal
Connector
Terminal
F88
1
F88
3
Continuity should exist.
EC-942
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0409 EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR
P0409 EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR
DTC Logic
INFOID:0000000006496628
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000006496629
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground inspection in
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR POWER SUPPLY CIRCUIT
1.
Disconnect EGR volume control valve harness connector.
2.
Turn ignition switch ON.
3.
Check the voltage between EGR volume control valve control position sensor connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR GROUND CIRCUIT FOR
OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between EGR volume control valve control position sensor harness connector and
ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR INPUT CIRCUIT FOR OPEN
AND SHORT
1.
Check the continuity between EGR volume control valve control position sensor harness connector and
ECM harness connector.
DTC No.
Trouble diagnosis name
Possible Cause
P0409
EGR VOLUME CONTROL VALVE CONTROL POSITION SEN-
SOR CIRCUIT
• Harness or connectors
(The EGR volume control valve control position
sensor circuit is open or shorted.)
• EGR volume control valve control position sensor
EGR volume control valve control position sensor
Ground
Voltage
Connector
Terminal
F88
1
Ground
Approx. 5V
EGR volume control valve control posi-
tion sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F88
3
E58
59
Existed
P0409 EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR
EC-943
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
, “INCIDENT SIMULATION TESTS” and “GROUND INSPECTION”.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace.
6.
REPLACE EGR VOLUME CONTROL VALVE
1.
Replace the EGR volume control valve.
2.
>> INSPECTIO END
EGR volume control valve control posi-
tion sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F88
5
E58
38
Existed
EC-944
< DTC/CIRCUIT DIAGNOSIS >
[K9K]
P0470 EXHAUST GAS PRESSURE SENSOR 1
P0470 EXHAUST GAS PRESSURE SENSOR 1
DTC Logic
INFOID:0000000006496630
DTC DETECTION LOGIC
NOTE:
If DTC P0470 is displayed with DTC P0651 or P2263, first perform trouble diagnosis for DTC P0651 or P2263.
Refer to
Diagnosis Procedure
INFOID:0000000006496631
1.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF and wait at least 20 seconds.
2.
Check ground connection E38. Refer to Ground inspection in
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace ground connection.
2.
CHECK EXHAUST GAS PRESSURE SENSOR 1 POWER SUPPLY CIRCUIT
1.
Disconnect exhaust gas pressure sensor 1 harness connector.
2.
Turn ignition switch ON.
3.
Check the voltage between exhaust pressure sensor 1 harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.
CHECK EXHAUST GAS PRESSURE SENSOR 1 GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF and wait at least 20 seconds.
2.
Check the continuity between exhaust gas pressure sensor 1 harness connector and ECM harness con-
nector.
3.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK EXHAUST GAS PRESSURE SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between exhaust gas pressure sensor 1 harness connector and ECM harness con-
nector.
DTC No.
Trouble diagnosis name
Possible cause
P0470
Exhaust gas pressure sensor 1 circuit
• 2.DEF: Signal outside lower limit
• 3.DEF: Signal outside upper limit
• Harness or connectors
(The exhaust gas pressure sensor 1 circuit is open or
shorted.)
• Exhaust gas pressure sensor 1
Exhaust gas pressure sensor 1
Ground
Voltage
Connector
Terminal
F67
3
Ground
Approx. 5 V
Exhaust gas pressure sensor 1
ECM
Continuity
Connector
Terminal
Connector
Terminal
F67
1
F58
23
Existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.