Nissan Pathfinder. Manual — part 482

EC-234

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

P0138, P0158 HO2S2

Component Function Check

INFOID:0000000009178159

1.

PERFORM COMPONENT FUNCTION CHECK-1

Without CONSULT

1. Start engine and warm it up to the normal operating temperature.

2. Turn ignition switch OFF and wait at least 10 seconds.

3. Turn ignition switch ON.

4. Turn ignition switch OFF and wait at least 10 seconds.

5. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.

6. Let engine idle for 1 minute.

7. Check the voltage between ECM harness connector terminals under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

PERFORM COMPONENT FUNCTION CHECK-2

Check the voltage between ECM harness connector terminals under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 3.

3.

PERFORM COMPONENT FUNCTION CHECK-3

Check the voltage between ECM harness connector terminals under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Proceed to

EC-235, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009178160

1.

INSPECTION START

Confirm the detected malfunction (A or B). Refer to

EC-233, "DTC Logic"

.

Which malfunction is detected?

A

>> GO TO 2.

B

>> GO TO 6.

DTC

ECM

Condition

Voltage

Connector

+

Terminal

P0138

F52

57

59

Revving up to 4,000 rpm under no load
at least 10 times

The voltage should be below 0.18 V at
least once during this procedure.

P0158

58

DTC

ECM

Condition

Voltage

Connector

+

Terminal

P0138

F52

57

59

Keeping engine speed at idle for 10
minutes

The voltage should be below 0.18 V
at least once during this procedure.

P0158

58

DTC

ECM

Condition

Voltage

Connector

+

Terminal

P0138

F52

57

59

Coasting from 80 km/h (50 MPH) with se-
lector lever in the D position

The voltage should be below 0.18 V at
least once during this procedure.

P0158

58

P0138, P0158 HO2S2

EC-235

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

2.

CHECK HO2S2 CONNECTOR FOR WATER

1. Disconnect heated oxygen sensor 2 harness connector.

2. Check that water is not inside connectors.
Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness or connectors.

3.

CHECK HO2S2 GROUND CIRCUIT

1. Disconnect heated oxygen sensor 2 harness connector.

2. Disconnect ECM harness connector.

3. Check the continuity between heated oxygen sensor 2 (HO2S2) harness connector and ECM harness

connector.

4. Also check harness for short to ground and short to power.
Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

4.

CHECK HO2S2 INPUT SIGNAL CIRCUIT

1. Check the continuity between HO2S2 harness connector and ECM harness connector.

2. Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and

ground.

3. Also check harness for short to power.
Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

5.

CHECK HEATED OXYGEN SENSOR 2

Check heated oxygen sensor 2. Refer to

EC-238, "Component Inspection"

.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to

GI-49, "Intermittent Incident"

.

DTC

HO2S2

ECM

Continuity

Bank

Connector

Terminal

Connector

Terminal

P0138

1

F13

1

F52

59

Existed

P0158

2

F12

1

DTC

HO2S2

ECM

Continuity

Bank

Connector

Terminal

Connector

Terminal

P0138

1

F13

4

F52

57

Existed

P0158

2

F12

4

58

DTC

HO2S2

Ground

Continuity

Bank

Connector

Terminal

P0138

1

F13

4

Ground

Not existed

P0158

2

F12

4

DTC

ECM

Ground

Continuity

Connector

Terminal

P0138

F52

57

Ground

Not existed

P0158

58

EC-236

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

P0138, P0158 HO2S2

NO

>> Replace malfunctioning heated oxygen sensor 2. Refer to

EM-31, "Removal and Installation

(bank 2)"

,

EM-33, "Removal and Installation (bank 1)"

.

6.

CLEAR MIXTURE RATIO SELF-LEARNING VALUE

1. Clear the mixture ratio self-learning value. Refer to

EC-145, "Work Procedure"

.

2. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 or P0175 detected? Is it difficult to start engine?

YES

>> Perform trouble diagnosis for DTC P0172, P0175. Refer to

EC-256, "DTC Logic"

.

NO

>> GO TO 7.

7.

CHECK HO2S2 GROUND CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect heated oxygen sensor 2 harness connector.

3. Disconnect ECM harness connector.

4. Check the continuity between HO2S2 harness connector and ECM harness connector.

5. Also check harness for short to ground and short to power.
Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

8.

CHECK HO2S2 INPUT SIGNAL CIRCUIT

1. Check the continuity between HO2S2 harness connector and ECM harness connector.

2. Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and

ground.

3. Also check harness for short to power.
Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

9.

CHECK HEATED OXYGEN SENSOR 2

Check heated oxygen sensor 2. Refer to

EC-238, "Component Inspection"

Is the inspection result normal?

DTC

HO2S2

ECM

Continuity

Bank

Connector

Terminal

Connector

Terminal

P0138

1

F13

1

F52

59

Existed

P0158

2

F12

1

DTC

HO2S2

ECM

Continuity

Bank

Connector

Terminal

Connector

Terminal

P0138

1

F13

4

F52

57

Existed

P0158

2

F12

4

58

DTC

HO2S2

Ground

Continuity

Bank

Connector

Terminal

P0138

1

F13

4

Ground

Not existed

P0158

2

F12

4

DTC

ECM

Ground

Continuity

Connector

Terminal

P0138

F52

57

Ground

Not existed

P0158

58

P0138, P0158 HO2S2

EC-237

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

YES

>> Check intermittent incident. Refer to

GI-49, "Intermittent Incident"

.

NO

>> Replace malfunctioning heated oxygen sensor 2. Refer to

EM-31, "Removal and Installation

(bank 2)"

,

EM-33, "Removal and Installation (bank 1)"

.

Component Inspection

INFOID:0000000009178161

1.

INSPECTION START

Will CONSULT be used?
Will CONSULT be used?

YES

>> GO TO 2.

NO

>> GO TO 3.

2.

CHECK HEATED OXYGEN SENSOR 2

With CONSULT

1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT.

2. Start engine and warm it up to the normal operating temperature.

3. Turn ignition switch OFF and wait at least 10 seconds.

4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.

5. Let engine idle for 1 minute.

6. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select “HO2S2 (B1)/(B2)” as the monitor item

with CONSULT.

7. Check “HO2S2 (B1)/(B2)” at idle speed when adjusting “FUEL INJECTION” to

± 25%.

“HO2S2 (B1)/(B2)” should be above 0.68 V at least once when the “FUEL INJECTION” is + 25%.

“HO2S2 (B1)/(B2)” should be below 0.18 V at least once when the “FUEL INJECTION” is

25%.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace malfunctioning heated oxygen sensor 2. Refer to

EM-31, "Removal and Installation

(bank 2)"

,

EM-33, "Removal and Installation (bank 1)"

.

3.

CHECK HEATED OXYGEN SENSOR 2-I

Without CONSULT

1. Start engine and warm it up to the normal operating temperature.

2. Turn ignition switch OFF and wait at least 10 seconds.

3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.

4. Let engine idle for 1 minute.

5. Check the voltage between ECM harness connector terminals under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 4.

PBIB3458E

ECM

Condition

Voltage

Connector

+

Terminal

F52

57

59

Revving up to 4,000 rpm under
no load at least 10 times

The voltage should be above 0.68 V at least once during this
procedure.
The voltage should be below 0.18 V at least once during this
procedure.

58

Была ли эта страница вам полезна?
Да!Нет
2 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности