Nissan Teana J32. Manual — part 321
REMOTE KEYLESS ENTRY RECEIVER
DLK-67
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
REMOTE KEYLESS ENTRY RECEIVER
Description
INFOID:0000000003794867
Receives Intelligent Key operation and transmits to BCM.
Component Function Check
INFOID:0000000003794868
1.
CHECK FUNCTION
With CONSULT-III
Check remote keyless entry receiver (“RKE OPE COUN1”) in Data Monitor mode with CONSULT-III.
Is the inspection result normal?
YES
>> Remote keyless entry receiver is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000003794869
1.
CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Check signal between remote keyless entry receiver harness connector and ground with oscilloscope.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
1.
Disconnect BCM connector and remote keyless entry receiver connector.
2.
Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
3.
Check continuity between BCM harness connector and ground.
Monitor item
Condition
RKE OPE COUN1
Checks whether value changes when operating Intelligent Key.
(+)
(–)
Condition
Signal
(Reference value)
Remote keyless entry receiver
Connector
Terminal
M78
2
Ground
Waiting
(All doors closed)
When signal is received
(All doors closed)
JMKIA0064GB
JMKIA0065GB
BCM
Remote keyless entry receiver
Continuity
Connector
Terminal
Connector
Terminal
M122
83
M78
2
Existed
DLK-68
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
REMOTE KEYLESS ENTRY RECEIVER
Is the inspection result normal?
YES
>> INSPECTION END.
NO
>> Repair or replace harness.
3.
CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
Check signal between remote keyless entry receiver harness connector and ground with oscilloscope.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 2
1.
Disconnect BCM connector and remote keyless entry receiver.
2.
Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-78, "Removal and Installation"
NO
>> Repair or replace harness.
5.
CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
1.
Disconnect BCM connector and remote keyless entry receiver.
2.
Check continuity between BCM connector and remote keyless entry receiver connector.
3.
Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M122
83
Not existed
(+)
(–)
Signal
(Reference value)
Remote keyless entry receiver
Connector
Terminal
M78
4
Ground
JMKIA0064GB
BCM
Remote keyless entry receiver
Continuity
Connector
Terminal
Connector
Terminal
M122
103
M78
4
Existed
BCM
Ground
Continuity
Connector
Terminal
M122
103
Not existed
BCM
Remote keyless entry receiver
Continuity
Connector
Terminal
Connector
Terminal
M123
137
M78
1
Existed
REMOTE KEYLESS ENTRY RECEIVER
DLK-69
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace harness.
6.
CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT 2
1.
Connect remote keyless entry receiver connector.
2.
Check continuity between remote keyless entry receiver harness connector and ground.
Is the inspection result normal?
YES
>> Replace remote keyless entry receiver. Refer to
DLK-244, "Removal and Installation"
NO
>> Replace BCM. Refer to
BCS-78, "Removal and Installation"
BCM
Ground
Continuity
Connector
Terminal
M122
137
Not existed
Remote keyless entry receiver
Ground
Continuity
Connector
Terminal
M78
1
Existed
DLK-70
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER SWITCH
TRUNK LID OPENER SWITCH
Description
INFOID:0000000003794870
Output trunk lid open signal to BCM.
Component Function Check
INFOID:0000000003794871
1.
CHECK FUNCTION
Check trunk lid opener switch (“TR/BD OPEN SW”) in “Data Monitor mode with CONSULT-III.
Is the inspection result normal?
YES
>> Trunk lid opener switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000003794872
1.
CHECK TRUNK LID OPENER INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect trunk lid opener switch connector.
3.
Check signal between trunk lid opener switch harness connector and ground with oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK TRUNK LID OPENER SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and trunk lid opener switch harness connector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-78, "Removal and Installation"
Monitor item
Condition
TR/BD OPEN SW
Trunk lid opener switch is pressed: ON
Trunk lid opener switch is released: OFF
(+)
(–)
Signal
(Reference value)
Trunk lid opener switch
Connector
Terminal
M25
1
Ground
JPMIA0011GB
BCM
Trunk lid opener switch
Continuity
Connector
Terminal
Connector
Terminal
M121
67
M25
1
Existed
BCM
Ground
Continuity
Connector
Terminal
M121
67
Not existed