Nissan Teana J32. Manual — part 322
TRUNK LID OPENER SWITCH
DLK-71
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
NO
>> Repair or replace harness.
3.
CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK TRUNK LID OPENER SWITCH
DLK-71, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace trunk lid opener switch. Refer to
DLK-243, "Removal and Installation"
5.
CHECK INTERMITTENT INCIDENT
GI-35, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000003794873
1.
CHECK TRUNK LID OPENER SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect trunk lid opener switch connector.
3.
Check continuity between trunk lid opener switch terminal.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace trunk lid opener switch. Refer to
DLK-243, "Removal and Installation"
Trunk lid opener switch
Ground
Continuity
Connector
Terminal
M25
2
Existed
Trunk lid opener switch
Condition
Continuity
Terminal
1
2
ON (press and hold)
Existed
OFF (release)
Not existed
DLK-72
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR REQUEST SWITCH
DOOR REQUEST SWITCH
Description
INFOID:0000000003794874
Transmits lock/unlock operation to BCM.
Component Function Check
INFOID:0000000003794875
1.
CHECK FUNCTION
Check door request switch (“REQ SW-DR” or “REQ SW-AS”) in Data Monitor mode.
Is the inspection result normal?
YES
>> Door request switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000003794876
1.
CHECK BCM OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect malfunctioning front outside handle (request switch) connector.
3.
Check signal between malfunctioning front outside handle (request switch) harness connector and ground
with oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR REQUEST SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and malfunctioning front outside handle (request
switch) harness connector.
3.
Check continuity between BCM harness connector and ground.
Monitor item
Condition
DR REQ SW
AS REQ SW
Door request switch is pressed: ON
Door request switch is released: OFF
(+)
(–)
Signal
(Reference value)
Front outside handle (request switch)
Connector
Terminal
LH
D11
1
Ground
RH
D50
JMKIA0059GB
BCM
Front outside handle (request switch)
Continuity
Connector
Terminal
Connector
Terminal
M122
101
LH
D11
1
Existed
100
RH
D50
DOOR REQUEST SWITCH
DLK-73
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-78, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between malfunctioning front outside handle (request switch) harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR REQUEST SWITCH
DLK-73, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace malfunctioning front outside handle. Refer to
DLK-224, "OUTSIDE HANDLE : Removal
.
5.
CHECK INTERMITTENT INCIDENT
GI-35, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000003794877
1.
CHECK DOOR REQUEST SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect front outside handle (request switch) connector.
3.
Check front outside handle (request switch).
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front outside handle. Refer to
DLK-224, "OUTSIDE HANDLE : Removal and Installation"
.
BCM
Ground
Continuity
Connector
Terminal
M122
101
Not existed
100
Front outside handle (request switch)
Ground
Continuity
Connector
Terminal
LH
D11
2
Existed
RH
D50
Front outside handle (request switch)
Door request switch condition
Continuity
Terminal
1
2
Pressed
Existed
Released
Not existed
DLK-74
< COMPONENT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER REQUEST SWITCH
TRUNK LID OPENER REQUEST SWITCH
Description
INFOID:0000000003794878
Performs trunk lid open request when it is pressed.
Component Function Check
INFOID:0000000003794879
1.
CHECK FUNCTION
Check trunk lid opener request switch (“REQ SW -BD/TR ”) in Data Monitor mode.
Is the inspection result normal?
YES
>> Trunk lid opener request switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000003794880
1.
CHECK TRUNK LID OPENER SWITCH OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect trunk lid opener request switch connector.
3.
Check signal between trunk lid opener request switch harness connector and ground with oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and trunk lid opener request switch harness connec-
tor.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
Monitor item
Condition
REQ SW -BD/TR
Trunk lid opener request switch is pressed: ON
Trunk lid opener request switch is released: OFF
(+)
(–)
Signal
(Reference value)
Trunk lid opener request switch
Connector
Terminal
T6
1
Ground
JPMIA0016GB
BCM
Trunk lid opener request switch
Continuity
Connector
Terminal
Connector
Terminal
M121
61
T6
1
Existed
BCM
Ground
Continuity
Connector
Terminal
M121
61
Not existed