Nissan Murano Z51 (2008 year). Manual — part 154
EC-280
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0442 EVAP CONTROL SYSTEM
2.
Check for genuine NISSAN fuel filler cap design.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Replace with genuine NISSAN fuel filler cap.
2.
CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Open fuel filler cap, then clean cap and fuel filler neck threads using air blower. Retighten until
ratcheting sound is heard.
3.
CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
CHECK FUEL TANK VACUUM RELIEF VALVE
EC-283, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace fuel filler cap with a genuine one.
5.
CHECK FOR EVAP LEAKAGE
.
Is there any leakage in EVAP line?
YES
>> Repair or replace malfunctioning part.
NO
>> GO TO 6.
6.
CHECK EVAP CANISTER VENT CONTROL VALVE
Check the following.
• EVAP canister vent control valve is installed properly.
EC-549, "Removal and Installation"
.
• EVAP canister vent control valve.
EC-294, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair or replace EVAP canister vent control valve and O-ring.
7.
CHECK IF EVAP CANISTER IS SATURATED WITH WATER
SEF915U
Revision: 2008 October
2009 Murano
P0442 EVAP CONTROL SYSTEM
EC-281
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Remove EVAP canister with EVAP canister vent control valve and
EVAP control system pressure sensor attached.
Does water drain from the EVAP canister?
YES
>> GO TO 8.
NO-1
>> With CONSULT-III: GO TO 10.
NO-2
>> Without CONSULT-III: GO TO 11.
8.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 10.
YES-2 >> Without CONSULT-III: GO TO 11.
NO
>> GO TO 9.
9.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
10.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1.
Disconnect vacuum hose from EVAP canister purge volume control solenoid valve at EVAP service port.
2.
Start engine.
3.
Perform “PURG VOL C/V” in “ACTIVE TEST” mode.
4.
Touch “Qu” on CONSULT-III screen to increase “PURG VOL C/V” opening to 100%.
5.
Check vacuum hose for vacuum.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> GO TO 12.
11.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-III
1.
Start engine and warm it up to normal operating temperature.
2.
Stop engine.
3.
Disconnect vacuum hose from EVAP canister purge volume control solenoid valve at EVAP service port.
4.
Start engine and let it idle for at least 80 seconds.
5.
Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> GO TO 12.
12.
CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to
Is the inspection result normal?
JMBIA1134GB
Vacuum should exist.
Vacuum should exist.
Revision: 2008 October
2009 Murano
EC-282
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0442 EVAP CONTROL SYSTEM
YES
>> GO TO 13.
NO
>> Repair or reconnect the hose.
13.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 14.
NO
>> Replace EVAP canister purge volume control solenoid valve.
14.
CHECK FUEL TANK TEMPERATURE SENSOR
EC-238, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> Replace fuel level sensor unit and fuel pump.
15.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-302, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 16.
NO
>> Replace EVAP control system pressure sensor.
16.
CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or improper connection.
Refer to
Is the inspection result normal?
YES
>> GO TO 17.
NO
>> Repair or reconnect the hose.
17.
CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 18.
18.
CHECK EVAP/ORVR LINE
Check EVAP/ORVR line between EVAP canister and fuel tank for clogging, kinks, looseness and improper
connection. For location, refer to
.
Is the inspection result normal?
YES
>> GO TO 19.
NO
>> Repair or replace hoses and tubes.
19.
CHECK RECIRCULATION LINE
Check recirculation line between filler neck tube and fuel tank for clogging, kinks, cracks, looseness and
improper connection.
Is the inspection result normal?
YES
>> GO TO 20.
NO
>> Repair or replace hose, tube or filler neck tube.
20.
CHECK REFUELING EVAP VAPOR CUT VALVE
EC-460, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 21.
NO
>> Replace refueling EVAP vapor cut valve with fuel tank.
21.
CHECK FUEL LEVEL SENSOR
MWI-47, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 22.
Revision: 2008 October
2009 Murano
P0442 EVAP CONTROL SYSTEM
EC-283
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
NO
>> Replace fuel level sensor unit and fuel pump.
22.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000003388054
1.
CHECK FUEL FILLER CAP
1.
Turn ignition switch OFF.
2.
Remove fuel filler cap.
3.
Wipe clean valve housing.
4.
Install fuel filler cap adapter (commercial service tool) to fuel filler cap.
5.
Check valve opening pressure and vacuum.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
REPLACE FUEL FILLER CAP
Replace fuel filler cap.
CAUTION:
Use only a genuine fuel filler cap as a replacement. If an incorrect fuel filler cap is used, the MIL may
illuminate.
>> INSPECTION END
SEF445Y
Pressure:
15.3 - 20.0 kPa (0.156 - 0.204 kg/cm
2
, 2.22 -
2.90 psi)
Vacuum:
−
6.0 to
−
3.3 kPa (
−
0.061 to
−
0.034 kg/cm
2
,
−
0.87 to
−
0.48 psi)
SEF943S
Revision: 2008 October
2009 Murano
EC-284
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Description
INFOID:0000000003388055
The EVAP canister purge volume control solenoid valve is used to
control the flow rate of fuel vapor from the EVAP canister. The EVAP
canister purge volume control solenoid valve is moved by ON/OFF
pulses from the ECM. The longer the ON pulse, the greater the
amount of fuel vapor that will flow through the valve.
DTC Logic
INFOID:0000000003388056
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.
Turn ignition switch OFF and wait at least 10 seconds.
2.
Turn ignition switch ON.
3.
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5
°
C (41
°
F) or more.
Will CONSULT-III be used?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-III
1.
Start engine and warm it up to normal operating temperature.
2.
Turn ignition switch OFF and wait at least 10 seconds.
3.
Turn ignition switch ON.
4.
Turn ignition switch OFF and wait at least 10 seconds.
5.
Turn ignition switch ON.
6.
Select “PURG VOL C/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
7.
Touch “START”.
8.
Start engine and let it idle until “TESTING” on CONSULT-III changes to “COMPLETED”. (It will take
approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
9.
Touch “SELF-DIAG RESULTS”.
Which is displayed on CONSULT-III screen?
PBIB3489E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0443
EVAP canister purge
volume control solenoid
valve
The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
• EVAP control system pressure sensor
• EVAP canister purge volume control so-
lenoid valve
(The valve is stuck open.)
• EVAP canister vent control valve
• EVAP canister
• Hoses
(Hoses are connected incorrectly or
clogged.)
Revision: 2008 October
2009 Murano
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-285
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
OK
>> INSPECTION END
NG
>> Go to
3.
PERFORM DTC CONFIRMATION PROCEDURE
With GST
1.
Start engine and warm it up to normal operating temperature.
2.
Turn ignition switch OFF and wait at least 10 seconds.
3.
Turn ignition switch ON.
4.
Turn ignition switch OFF and wait at least 10 seconds.
5.
Start engine and let it idle for at least 20 seconds.
6.
Check 1st trip DTC.
Is 1st trip DTC displayed?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000003388057
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister purge volume control solenoid valve harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between EVAP canister purge volume control solenoid valve harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors F121, E7
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
• Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit, short to ground or short to power in harness or connectors.
3.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between EVAP canister purge volume control solenoid valve harness connector and
ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
EVAP canister purge volume control
solenoid valve
Ground
Voltage
Connector
Terminal
F30
1
Ground
Battery voltage
EVAP canister purge volume con-
trol solenoid valve
ECM
Continuity
Connector
Terminal
Connector
Terminal
F30
2
F7
25
Existed
Revision: 2008 October
2009 Murano
EC-286
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
4.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1.
Disconnect EVAP control system pressure sensor harness connector.
2.
Check that water is not inside connectors.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace EVAP control system pressure sensor.
5.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-302, "Component Inspection"
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 6.
YES-2 >> Without CONSULT-III: GO TO 7.
NO
>> Replace EVAP control system pressure sensor.
6.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
1.
Turn ignition switch OFF.
2.
Reconnect harness connectors disconnected.
3.
Start engine.
4.
Perform “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed varies
according to the valve opening.
Does engine speed vary according to the valve opening?
YES
>> GO TO 8.
NO
>> GO TO 7.
7.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Replace EVAP canister purge volume control solenoid valve.
8.
CHECK RUBBER TUBE FOR CLOGGING
1.
Disconnect rubber tube connected to EVAP canister vent control valve.
2.
Check the rubber tube for clogging.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Clean the rubber tube using an air blower.
9.
CHECK EVAP CANISTER VENT CONTROL VALVE
EC-294, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> Replace EVAP canister vent control valve.
10.
CHECK IF EVAP CANISTER IS SATURATED WITH WATER
Remove EVAP canister with EVAP canister vent control valve and
EVAP control system pressure sensor attached.
Does water drain from the EVAP canister?
YES
>> GO TO 11.
NO
>> GO TO 13.
JMBIA1134GB
Revision: 2008 October
2009 Murano
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-287
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
11.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> GO TO 12.
12.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
13.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000003388058
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
1.
Turn ignition switch OFF.
2.
Reconnect all harness connectors disconnected.
3.
Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4.
Turn ignition switch ON.
5.
Select “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT-III.
6.
Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG
VOL C/V” opening and check air passage continuity of EVAP
canister purge volume control solenoid valve under the following
conditions.
Without CONSULT-III
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister purge volume control solenoid valve harness connector.
3.
Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4.
Check air passage continuity of EVAP canister purge volume
control solenoid valve under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
Condition
(PURG VOL C/V value)
Air passage continuity
between (A) and (B)
100%
Existed
0%
Not existed
PBIB2058E
Condition
Air passage continuity
between (A) and (B)
12 V direct current supply between
terminals 1 and 2
Existed
No supply
Not existed
PBIB2059E
Revision: 2008 October
2009 Murano
EC-288
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
NO
>> Replace EVAP canister purge volume control solenoid valve
Revision: 2008 October
2009 Murano
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-289
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
Description
INFOID:0000000003597996
The EVAP canister purge volume control solenoid valve is used to
control the flow rate of fuel vapor from the EVAP canister. The EVAP
canister purge volume control solenoid valve is moved by ON/OFF
pulses from the ECM. The longer the ON pulse, the greater the
amount of fuel vapor that will flow through the valve.
DTC Logic
INFOID:0000000003388060
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
CONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.
Turn ignition switch OFF and wait at least 10 seconds.
2.
Turn ignition switch ON.
3.
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Start engine and let it idle for at least 13 seconds.
2.
Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000003388061
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister purge volume control solenoid valve harness connector.
3.
Turn ignition switch ON.
PBIB3489E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0444
EVAP canister purge volume
control solenoid valve circuit
open
An excessively low voltage signal is sent
to ECM through the valve
• Harness or connectors
(The solenoid valve circuit is open or
shorted.)
• EVAP canister purge volume control so-
lenoid valve
P0445
EVAP canister purge volume
control solenoid valve circuit
shorted
An excessively high voltage signal is sent
to ECM through the valve
• Harness or connectors
(The solenoid valve circuit is shorted.)
• EVAP canister purge volume control so-
lenoid valve
Revision: 2008 October
2009 Murano
EC-290
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
4.
Check the voltage between EVAP canister purge volume control solenoid valve harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors F121, E7
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
• Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit, short to ground or short to power in harness or connectors.
3.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between EVAP canister purge volume control solenoid valve harness connector and
ECM harness connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES-1 >> With CONSULT-III: GO TO 4.
YES-2 >> Without CONSULT-III: GO TO 5.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
4.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-III
1.
Reconnect all harness connectors disconnected.
2.
Start engine.
3.
Perform “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed varies
according to the valve opening.
Does engine speed vary according to the valve opening?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-291, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace EVAP canister purge volume control solenoid valve.
6.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
EVAP canister purge volume control
solenoid valve
Ground
Voltage
Connector
Terminal
F30
1
Ground
Battery voltage
EVAP canister purge volume con-
trol solenoid valve
ECM
Continuity
Connector
Terminal
Connector
Terminal
F30
2
F7
25
Existed
Revision: 2008 October
2009 Murano
P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-291
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
>> INSPECTION END
Component Inspection
INFOID:0000000003591644
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
1.
Turn ignition switch OFF.
2.
Reconnect all harness connectors disconnected.
3.
Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4.
Turn ignition switch ON.
5.
Select “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT-III.
6.
Touch “Qd” and “Qu” on CONSULT-III screen to adjust “PURG
VOL C/V” opening and check air passage continuity of EVAP
canister purge volume control solenoid valve under the following
conditions.
Without CONSULT-III
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister purge volume control solenoid valve harness connector.
3.
Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4.
Check air passage continuity of EVAP canister purge volume
control solenoid valve under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace EVAP canister purge volume control solenoid
valve
Condition
(PURG VOL C/V value)
Air passage continuity
between (A) and (B)
100%
Existed
0%
Not existed
PBIB2058E
Condition
Air passage continuity
between (A) and (B)
12 V direct current supply between
terminals 1 and 2
Existed
No supply
Not existed
PBIB2059E
Revision: 2008 October
2009 Murano
EC-292
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0447 EVAP CANISTER VENT CONTROL VALVE
P0447 EVAP CANISTER VENT CONTROL VALVE
Description
INFOID:0000000003388063
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows “EVAP
Control System” diagnosis.
DTC Logic
INFOID:0000000003388064
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.
Turn ignition switch OFF and wait at least 10 seconds.
2.
Turn ignition switch ON.
3.
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Start engine and wait at least 8 seconds.
2.
Check 1st trip DTC.
Is 1st trip DTC detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000003388065
1.
INSPECTION START
Will CONSULT-III be used?
Will CONSULT-III be used?
YES
>> GO TO 2.
NO
>> GO TO 3.
2.
CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT-III
PBIB1263E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0447
EVAP canister vent con-
trol valve circuit open
An improper voltage signal is sent to ECM
through EVAP canister vent control valve.
• Harness or connectors
(The valve circuit is open or shorted.)
• EVAP canister vent control valve
• Hoses
(Hoses are connected incorrectly or
clogged.)
Revision: 2008 October
2009 Murano
P0447 EVAP CANISTER VENT CONTROL VALVE
EC-293
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
1.
Turn ignition switch OFF and then ON.
2.
Select “VENT CONTROL/V” in “ACTIVE TEST” mode with CONSULT-III.
3.
Touch “ON/OFF” on CONSULT-III screen.
4.
Check for operating sound of the valve.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 3.
3.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister vent control valve harness connector.
3.
Turn ignition switch ON.
4.
Check the voltage between EVAP canister vent control valve harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 4.
4.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors F121, E7
• Harness connectors E104, B4
• Harness for open or short between EVAP canister vent control valve and IPDM E/R
>> Repair open circuit, short to ground or short to power in harness or connectors.
5.
CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between ECM harness connector and EVAP canister vent control valve harness con-
nector.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 6.
6.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E104, B4
• Harness for open or short between EVAP canister vent control valve and ECM
>> Repair open circuit, short to ground or short to power in harness or connectors.
7.
CHECK RUBBER TUBE FOR CLOGGING
1.
Disconnect rubber tube connected to EVAP canister vent control valve.
Clicking sound should be heard.
EVAP canister vent control valve
Ground
Voltage
Connector
Terminal
B65
1
Ground
Battery voltage
EVAP canister vent control valve
ECM
Continuity
Connector
Terminal
Connector
Terminal
B65
2
E16
109
Existed
Revision: 2008 October
2009 Murano
EC-294
< COMPONENT DIAGNOSIS >
[VQ35DE]
P0447 EVAP CANISTER VENT CONTROL VALVE
2.
Check the rubber tube for clogging.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Clean the rubber tube using an air blower.
8.
CHECK EVAP CANISTER VENT CONTROL VALVE
EC-294, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Replace EVAP canister vent control valve.
9.
CHECK INTERMITTENT INCIDENT
GI-40, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000003388066
1.
CHECK EVAP CANISTER VENT CONTROL VALVE-I
1.
Remove EVAP canister vent control valve from EVAP canister.
2.
Check portion (A) of EVAP canister vent control valve for rust.
Is it rusted?
YES
>> Replace EVAP canister vent control valve.
NO
>> GO TO 2.
2.
CHECK EVAP CANISTER VENT CONTROL VALVE-II
With CONSULT-III
1.
Reconnect harness connectors disconnected.
2.
Turn ignition switch ON.
3.
Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
4.
Check air passage continuity and operation delay time.
Check that new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
1.
Disconnect EVAP canister vent control valve harness connector.
2.
Check air passage continuity and operation delay time under the
following conditions.
Check that new O-ring is installed properly.
Operation takes less than 1 second.
JMBIA0168ZZ
Condition VENT CONTROL/V
Air passage continuity between (A) and (B)
ON
Not existed
OFF
Existed
Condition
Air passage continuity between (A) and (B)
12 V direct current supply between
terminals 1 and 2
Not existed
OFF
Existed
JMBIA0169ZZ
Revision: 2008 October
2009 Murano
P0447 EVAP CANISTER VENT CONTROL VALVE
EC-295
< COMPONENT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 3.
3.
CHECK EVAP CANISTER VENT CONTROL VALVE-III
With CONSULT-III
1.
Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.
2.
Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.
3.
Check air passage continuity and operation delay time.
Check that new O-ring is installed properly.
Operation takes less than 1 second.
Without CONSULT-III
1.
Clean the air passage [portion (A) to (B)] of EVAP canister vent
control valve using an air blower.
2.
Check air passage continuity and operation delay time under the
following conditions.
Check that new O-ring is installed properly.
Operation takes less than 1 second.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace EVAP canister vent control valve
Condition VENT CONTROL/V
Air passage continuity between (A) and (B)
ON
No
OFF
Yes
Condition
Air passage continuity between (A) and (B)
12 V direct current supply between
terminals (1) and (2)
No
OFF
Yes
JMBIA0169ZZ
Revision: 2008 October
2009 Murano