Kia Carnival (2009+). Manual — part 315
2009 > G 2.7 DOHC >
INSPECTION
1. If the value is out of specification according to the chart below, remove the valve body cover.
2. Measure the resistance again after disconnecting solenoid valve connector.
Specification (20°C):
2.5 ~ 3.5 ! (LR, 2ND, UD, OD, TCC)
3. If the value is out of specification replace the solenoid valve.
Pin No.
Name
Resistance
6&9
DCC (TCC)
2.5~3.5! (20°C)
6&11
LR
4&5
2ND
3&5
UD
5&12
OD
Automatic Transaxle System
Valve Body System - VFS (Variable Force
Solenoid) Valve
Automatic Transaxle System
2009 > G 2.7 DOHC >
DESCRIPTION
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C~130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 ! (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 ! (VFS)
- Surge voltage: 56 V (Except VFS)
(VFS)
Location
VFS Control pressure
Input Current(mA)
Control Pressure (No line pressure)
Increasing Current
Decreasing Current
MAX. (Kgf/cm!)
[Kpa]
MIN. (Kgf/cm!)
[Kpa]
" (Kgf/cm!)
[Kpa]
MIN. (Kgf/cm!)
[Kpa]
100
6.52
[639]
5.87
[575]
[64]
200
6.23
[611]
5.70
[559]
[52]
5.43
[532]
300
5.76
[564]
5.24
[514]
[50]
4.49
[484]
400
5.08
[498]
4.59
[450]
[48]
4.30
[421]
500
4.24
[416]
3.78
[370]
[46]
3.52
[345]