Kia Carnival (2009+). Manual — part 315

2009 > G 2.7 DOHC >

INSPECTION

1. If the value is out of specification according to the chart below, remove the valve body cover.

2. Measure the resistance again after disconnecting solenoid valve connector.

Specification (20°C):
2.5 ~ 3.5 ! (LR, 2ND, UD, OD, TCC)

3. If the value is out of specification replace the solenoid valve.

Pin No.

Name

Resistance

6&9

DCC (TCC)

2.5~3.5! (20°C)

6&11

LR

4&5

2ND

3&5

UD

5&12

OD

Automatic Transaxle System

Valve Body System - VFS (Variable Force

Solenoid) Valve

Automatic Transaxle System

2009 > G 2.7 DOHC >

DESCRIPTION

Actuators

Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C~130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 ! (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 ! (VFS)
- Surge voltage: 56 V (Except VFS)

(VFS)

Location

VFS Control pressure

Input Current(mA)

Control Pressure (No line pressure)

Increasing Current

Decreasing Current

MAX. (Kgf/cm!)

Kpa

MIN. (Kgf/cm!)

Kpa

" (Kgf/cm!)

Kpa

MIN. (Kgf/cm!)

Kpa

100

6.52

[639]

5.87

[575]

[64]

200

6.23

[611]

5.70

[559]

[52]

5.43

[532]

300

5.76

[564]

5.24

[514]

[50]

4.49

[484]

400

5.08

[498]

4.59

[450]

[48]

4.30

[421]

500

4.24

[416]

3.78

[370]

[46]

3.52

[345]

Была ли эта страница вам полезна?
Да!Нет
4 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности