Ford Ranger EV (2001 year). Manual — part 107
414-03A-24
414-03A-24
High Voltage/Traction Battery
DIAGNOSIS AND TESTING (Continued)
PINPOINT TEST A: DTC C1835 CURRENT SENSE CIRCUIT FAILURE
TEST STEP
ACTION TO TAKE
No =
GO to A5.
WARNING: The traction battery contains high-voltage
components and wiring. High-voltage insulated safety gloves and face
shield must be worn when performing the following steps. Failure to
follow this warning may result in severe personal injury or death.
•
Connect Traction Battery High-Voltage Service Cord to traction battery
support tray in-line C1935F and in-line C1935M.
•
Connect Traction Battery Low-Voltage Service Cord to traction battery
support tray in-line C1939F and in-line C1939M.
•
Connect 104-Pin Breakout Box (BOB) to BCM C1986, C1987 using the
BCM/TIM BOB Adapter Cable and Overlay; leave the BCM
disconnected.
•
With key ON, measure the voltage between BOB pin A17 and ground
(BOB pin A33).
•
Is the voltage between 5 and 8 volts?
A5 CHECK CIRCUITS 3996 (R/Y) AND 3705 (LB) FOR OPEN(S)
•
With key OFF, disconnect contactor box C1982 and measure the
Yes =
GO to A6.
resistance of the R/Y wire between pin 21 on contactor box C1982 and
BOB pin A16.
•
With key OFF, measure the resistance of the LB wire between pin 22 on
No =
REPAIR the wire(s) in
contactor box C1982 and BOB pin A17.
question.
•
Are the resistances less than 5 ohms?
A6 CHECK CIRCUIT 3705 (LB) FOR SHORT TO GROUND
•
With key OFF, measure the resistance between BOB pin A17 and ground Yes =
GO to A7.
(BOB pin A33).
•
Is the resistance greater than 10,000 ohms?
No =
REPAIR the LB wire.
A7 CHECK CIRCUIT 3705 (LB) FOR SHORT TO POWER
•
With key ON, measure the voltage between BOB pin A17 and ground
Yes =
REPAIR the LB wire.
(BOB pin A33).
•
Is the voltage greater than 0 volts?
No =
REPLACE the contactor
box.
A8 CHECK MAIN CURRENT SENSOR SIGNAL TO BCM
•
Remove the traction battery and connect Traction Battery High-Voltage
Yes =
REPLACE the BCM.
Lockout and Diagnostic Tool to the traction battery high-voltage two-pin
C3994M.
No =
GO to A9.
WARNING: The traction battery contains high-voltage
components and wiring. High-voltage insulated safety gloves and face
shield must be worn when performing the following steps. Failure to
follow this warning may result in severe personal injury or death.
•
Connect Traction Battery High-Voltage Service Cord to traction battery
support tray in-line C1935F and in-line C1935M.
•
Connect Traction Battery Low-Voltage Service Cord to traction battery
support tray in-line C1939F and in-line C1939M.
•
Connect 104-Pin Breakout Box (BOB) to BCM C1986, C1987 using the
BCM/TIM BOB Adapter Cable and Overlay; leave the BCM
disconnected.
•
With key ON, measure the voltage between BOB pin A15 and ground
(BOB pin A33).
•
Is the voltage between 5 and 8 volts?
A9 CHECK CIRCUITS 3602 (T/Y) AND 3706 (DB) FOR OPEN(S)
•
With key OFF, disconnect contactor box C1982 and measure the
Yes =
resistance of the T/Y wire between pin 23 on contactor box C1982 and
BOB pin B1.
(Continued)
414-03A-25
414-03A-25
High Voltage/Traction Battery
DIAGNOSIS AND TESTING (Continued)
PINPOINT TEST A: DTC C1835 CURRENT SENSE CIRCUIT FAILURE
TEST STEP
ACTION TO TAKE
•
With key OFF, measure the resistance of the DB wire between pin 15 on No =
REPAIR the wire(s) in
contactor box C1982 and BOB pin A15.
question.
•
Are the resistances less than 5 ohms?
A10 CHECK CIRCUIT 3706 (DB) FOR SHORT TO GROUND
•
With key OFF, measure the resistance between BOB pin A15 and ground Yes =
GO to A11.
(BOB pin A33).
•
Is the resistance greater than 10,000 ohms?
No =
REPAIR the DB wire.
A11 CHECK CIRCUIT 3706 (DB) FOR SHORT TO POWER
•
With key ON, measure the voltage between BOB pin A15 and ground
Yes =
REPAIR the DB wire.
(BOB pin A33).
•
Is the voltage greater than 0 volts?
No =
REPLACE the contactor
box.
A12 CHECK CURRENT SENSE CONTROL DISABLE SIGNAL
•
Remove the traction battery and connect Traction Battery High-Voltage
Yes =
GO to A13.
Lockout and Diagnostic Tool to the traction battery high-voltage two-pin
C3994M.
No =
GO to A15.
WARNING: The traction battery contains high-voltage
components and wiring. High-voltage insulated safety gloves and face
shield must be worn when performing the following steps. Failure to
follow this warning may result in severe personal injury or death.
•
Connect Traction Battery High-Voltage Service Cord to traction battery
support tray in-line C1935F and in-line C1935M.
•
Connect Traction Battery Low-Voltage Service Cord to traction battery
support tray in-line C1939F and in-line C1939M.
•
Connect 104-Pin Breakout Box (BOB) to BCM and BCM C1986, C1987
using the BCM/TIM BOB Adapter Cable and Overlay.
•
Enter BCM active command mode BCM PACKETED COMMANDS, set
the active command CURRENT S to DISABLE, and measure the voltage
between BOB pin B22 and ground (BOB pin A33).
•
Is the voltage greater than 7.5 volts?
A13 CHECK CURRENT SENSE CONTROL ENABLE SIGNAL
•
Set the active command CURRENT S to ENABLE and measure the
Yes =
System OK. CHECK wiring
voltage between BOB pin B22 and ground (BOB pin A33).
for intermittent connections.
•
Is the voltage less than 1 volt?
No =
GO to A14.
A14 CHECK CIRCUIT 3138 (LB/BK) FOR SHORT TO POWER
•
With key OFF, disconnect the BOB from the BCM; leave BOB
Yes =
REPAIR the LB/BK wire.
connected to BCM C1986 and C1987.
•
With key OFF, disconnect contactor box C1982.
No =
REPLACE the BCM.
•
With key ON, measure the voltage between BOB pin B22 and ground
(BOB pin A33).
•
Is the voltage greater than 0 volts?
A15 CHECK CONTACTOR BOX SIGNAL TO BCM
•
With key OFF, disconnect the BOB from the BCM; leave BOB
Yes =
REPLACE the BCM.
connected to BCM C1986 and C1987.
•
With key ON, measure the voltage between BOB pin B22 and ground
No =
GO to A16.
(BOB pin A33).
•
Is the voltage between 7.5 and 9 volts?
A16 CHECK CIRCUIT 3138 (LB/BK) FOR OPEN
•
With key OFF, disconnect contactor box C1982 and measure the
Yes =
resistance of the LB/BK wire between pin 12 on contactor box C1982
and BOB pin B22.
(Continued)
414-03A-26
414-03A-26
High Voltage/Traction Battery
DIAGNOSIS AND TESTING (Continued)
PINPOINT TEST A: DTC C1835 CURRENT SENSE CIRCUIT FAILURE
TEST STEP
ACTION TO TAKE
•
Is the resistance less than 5 ohms?
No =
REPAIR the LB/BK wire.
A17 CHECK CIRCUIT 3138 (LB/BK) FOR SHORT TO GROUND
•
With key OFF, measure the resistance between BOB pin B22 and ground Yes =
REPLACE the contactor
(BOB pin A33).
box.
•
Is the resistance greater than 10,000 ohms?
No =
REPAIR the LB/BK wire.
Electrical Schematic
Current Leakage Detection
Refer to Electrical and Vacuum Troubleshooting
Diagnostic Trouble Code (DTC) Definition
Manual, Cell 16, Traction Battery System for
The following DTC relates to current leakage
schematic and connector information.
detection:
Inspection and Verification
•
DTC C1839 Leakage Fault
Refer to
— Current leakage is a low level of impedance
between vehicle chassis and either traction
battery positive (TB+) or traction battery
negative (TB-). The battery control module
(BCM) checks for a parallel combination of
bus leakage impedance (between vehicle
chassis and TB+, and between vehicle chassis
and TB-) during the charge and drive cycles.
The BCM sets DTC C1839 when it detects a
low level of leakage (between 10,000 and
50,000 ohms) during charging, high level
leakage (less than 10,000 ohms) during
charging, leakage (less than 50,000 ohms)
during driving, or if the leakage circuit fails.
The BCM uses PIDs to indicate when the
leakage occurred, the severity of the leakage
when it occurred, and the status of the leakage
circuits.
414-03A-27
414-03A-27
High Voltage/Traction Battery
DIAGNOSIS AND TESTING (Continued)
Symptom Chart
Symptom Chart
Condition
Possible Sources
Action
•
DTC C1839 Leakage Fault
•
High-voltage harness
•
(10B694).
•
High-voltage harness(es)
(14A280).
•
Battery control module
(BCM).
•
A/C inverter motor controller
(IMC).
•
A/C compressor.
•
Traction inverter module
(TIM).
•
Motor/transaxle.
•
Lower battery heater.
•
High-voltage harness
(10B700).
•
Upper battery heater.
•
Contactor box.
•
Power steering assembly.
•
Positive temperature
coefficient (PTC) heater.
•
PTC switching module.
•
DC/DC converter.
•
High-voltage power
distribution box (HVPDB).
•
Traction battery charger.
•
High-voltage harness
(14B322).
Special Tool(s)
Pinpoint Tests
Auxiliary Interlock Tool 418-F208
Special Tool(s)
Traction Battery High-Voltage Service Cord 418-F218
104-Pin Breakout Box (BOB) 418-049 (014-00950) or
Traction Battery Low-Voltage Service Cord 418-F219
equivalent
High-Voltage Insulated Safety Gloves 100-F036 or
Traction Battery High-Voltage Lockout and Diagnostic
equivalent
Tool 418-F207
Face Shield 100-F035 or equivalent
Power Steering Interlock Tool 211-F006
(Continued)
PINPOINT TEST A: DTC C1839 LEAKAGE FAULT
TEST STEP
ACTION TO TAKE
A1 CHECK FOR CURRENT LEAKAGE
•
With key ON, monitor battery control module (BCM) PIDs LEAK DF,
Yes =
LEAKHCF, and LEAKLCF.
vehicle somewhere).
•
Wait approximately 50 seconds.
•
Do any of the PIDs indicate YES?
No =
GO to A2 (leakage circuit
failure).
A2 CHECK FOR LEAKAGE CIRCUIT FAILURE
•
With key ON, monitor BCM PID LEAK CF.
Yes =
•
Wait approximately two minutes.
(Continued)