REMOVAL AND INSTALLATION (Continued)
3.
WARNING: The nominal voltage of
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4. Disconnect the independent observer module
(IOM) electrical connector.
1 Loosen the bolt.
2 Unclip the connector.
5. Remove the IOM.
1 Remove the bolts.
2 Remove the IOM.
414-03B-173
414-03B-173
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
Installation
1. To install, reverse the removal procedure.
414-03B-174
414-03B-174
High Voltage/Traction Battery — Nickel Metal Hydride
DISASSEMBLY AND ASSEMBLY
Traction Battery
Special Tool(s)
Battery Terminal Cap Opener
418-F215
Battery Post Torque Wrench
307-026
414-03B-175
414-03B-175
High Voltage/Traction Battery — Nickel Metal Hydride
DISASSEMBLY AND ASSEMBLY (Continued)
Traction Battery