Ford Ranger EV (2001 year). Manual — part 194

414-03B-172

414-03B-172

High Voltage/Traction Battery — Nickel Metal Hydride

REMOVAL AND INSTALLATION (Continued)

3.

WARNING: The nominal voltage of

the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to

Section 100-00

.

1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.

4. Disconnect the independent observer module

(IOM) electrical connector.
1 Loosen the bolt.
2 Unclip the connector.

5. Remove the IOM.

1 Remove the bolts.
2 Remove the IOM.

414-03B-173

414-03B-173

High Voltage/Traction Battery — Nickel Metal Hydride

REMOVAL AND INSTALLATION (Continued)

Installation

1. To install, reverse the removal procedure.

414-03B-174

414-03B-174

High Voltage/Traction Battery — Nickel Metal Hydride

DISASSEMBLY AND ASSEMBLY

Traction Battery

Special Tool(s)

Battery Terminal Cap Opener

418-F215

Battery Post Torque Wrench

307-026

414-03B-175

414-03B-175

High Voltage/Traction Battery — Nickel Metal Hydride

DISASSEMBLY AND ASSEMBLY (Continued)

Traction Battery