Geely Diagnosis Flow. Manual part — 84
Geely Diagnosis Flow. Manual part - 84
333
No. 238 Weak running of blower
Malfunction Cause
Solution
Malfunction of battery
Check if the voltage of battery reaches to 12.5 – 12.9V, if the over-low
voltage results in weak running of blower, the battery should be charged
or replaced ;
Worn-out or poor contact of
blower carbon brush
Replace blower assembly
Malfunction of blower coil
Check blower coil for short-circuit; check and measure if over-big
adjusting resistance of blower results in weak running; if it’s abnormal, the
blower assembly should be replaced;
Weak running of
blower
Malfunction of blower adjusting
resistance
Replace blower adjusting resistance;
Over-big resistance or short-circuit of blower coil
Replace blower
motor
Blocking or unsmooth running of blower blades
Replace blower
assembly
Weak running of blower
Over-low voltage for blower
Charge or replace battery
Abnormal
Normal
Normal
Abnormal
Over-low
334
No. 239 Blower can’t work
Malfunction
Cause
Solution
Malfunction of fuse
Check the fuse of blower for break and replace blower fuse if it’s broken;
Malfunction of blower
relay
Check #1 and #2 terminal of relay for conducting; if so, check #3 and #4 terminal of
relay for conducting while applying positive voltage to #1 and #2 terminal; if not,
the relay should be replaced;
Malfunction of blower
adjusting resistance
Check every coil of blower adjusting resistance for conducting; if not, the blower
adjusting resistance should be replaced;
Malfunction of blower
coil
Check blower coil for short-circuit or conducting; if it’s not conducted, the blower
motor should be replaced;
Malfunction of blower
switch
Check every connector of blower switch for conducting; if there is abnormal
connector, the blower switch should be replaced;
Malfunction of
harness
Check the harness of blower for short-circuit or break; if it's abnormal, the harness
of blower should be checked and repaired;
Blower can’t
work
Malfunction of blower
fan
Check blower fan for blocking or other object resulting in blocking, thus the blower
should be dismantled and checked;
Blower can’t work
Low voltage of battery
Broken fuse of blower
Malfunction of blower relay
Open circuit of blower speed governing
resistance
Short-circuit or open circuit of blower coil
Replace blower motor
Normal working of blower switch
Blocking or blocked blower fan
Replace blower fan
Replace blower
switch
Replace blower speed
governing resistance;
Replace blower relay
Charg or replace battery
Replace blower fuse
Open circuit or poor contact of connector loop for blower
Check and repair blower
loop
Abnormal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Open circuit
Abnormal
Break
Over-low
335
No. 240 Abnormal sound of blower
Malfunction Cause
Solution
Check working condition of brush for worn-out and if the friction between
brush and rotator of blower results in abnormal sound; if it's abnormal, the
blower motor or blower assembly should be replaced;
Internal malfunction of blower
Check bearing bush of blower for over-worn; if it's abnormal, the blower
motor or blower assembly should be replaced;
Check blower internally for other object; if so, the blower should be
dismantled to take other object out;
Abnormal sound of
blower
Other malfunctions
Check fixing bolt of blower blades and fastening bolt of blower for loosing;
tighten them if it’s abnormal;
Dismantle
blower
Impurity enters into blower
Loosing of internal blower blades
Dismantle
blower
Internal brush and bearing for blower in poor
operation
Replace
blower
Abnormal sound of blower
Abnormal
Normal
Abnormal
Abnormal
Normal
336
No. 241 Continuous running of cooling fan
Malfunction Cause
Solution
Malfunction of fan
relay
Check #1 and #2 terminal of relay for conducting; if so, check #3 and #4 terminal of relay
for conducting while applying positive voltage to #1 and #2 terminal; the #3 and #4
terminal should be conducted; if the two contacts are still normal-close resulting in
continuous running of fan, the relay should be replaced;
1. Check if the opening temperature of thermostat is 80 – 84 degree; if not, recirculation
and heat dispersion of cooling water will be bad and the high water temperature will
result in continuous running of fan; then the thermostat should be replaced;
Malfunction of
thermostat
2. Check thermostat valve for lift; when water temperature is about 93 degree, the lift
should bigger than 8 mm; if not, insufficient recirculation and heat dispersion of cooling
water will result in high water temperature and subsequent continuous running of fan;
then the thermostat should be replaced;
Temperature sensor
for coolant
Check if the resistance of coolant temperature sensor varies according to water
temperature; check if the resistance of sensor is 2.5 kOhm +/- 5% under 20 degree; if it's
abnormal, the temperature sensor for coolant should be replaced;
Other malfunctions
Check if there is leakage of coolant for radiator and cooling system; if so, it will result in
insufficient cooling water and high water temperature and subsequent continuous
running of fan, thus the leaking parts should be replaced or treated for sealing;
Malfunction of
harness
Check harness of fan motor for short-circuit or mixed connection; if it’s abnormal, the fan
loop should be checked and repaired;
Continuous
running of cooling
fan
Malfunction of
engine ECU
Check internal program of engine ECU for short-circuit or mixed connection; if it’s
abnormal, thus the engine ECU should be replaced;
Continuous
running of cooling
Leaking or insufficient coolant
Check cooling
system
No recirculation and heat dispersing
for coolant of radiator
Check, repair or
replace thermostat
Fan relay in poor operation
Replace fan
relay
Water temperature sensor in poor
operation
Short-circuit or break of fan loop
Replace water
temperature
Check and
repair fan loop
Engine ECU in poor operation
Replace engine
Abnormal
Normal
Abnormal
Abnormal
Abnormal
Abnormal
Leakage
Normal
Normal
Normal
Normal
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст