Geely CK (2008). Manual part — 44
Geely CK (2008). Manual part - 44
173
2. DEFINITION OF MULTIPIN PLUG-IN TERMINAL
Definition of Terminal
Color of Harness
1
Empty
2
EPS
VG
3
Empty
4
Empty
5
Empty
6
Empty
7
Empty
8 Combination switch (Position lamp P
9 Speed sensor groun B
10 Speed sensor power sourc RY
11 Speed sensor signal outpu YR
12 Fuel senso B
13
Alternator
WR
14 Brake fluid level switc GR
15 Oil pressure switc YG
16
Rear defrost
YB
1
Rear fog lamp
Gr
2
Engine malfunction
GY
3
Seat belt switch
R
4
Power source
Y
5 Engine coolant temperature senso YW
6
Park switch
G
7 Power source groun B
8 Power source groun B
9
ABS
R
10
SRS (Main)
RY
11
Engine revolution signal
BBl
12
Live wire (Fire wire)
WG
13
High beam lamp +
RB
14
Low beam -
RW
15
SRS (Sub)
RG
16
Empty
Terminal No.
A
B
174
Section 2 Malfunction Symptom Table and Solution Procedure
I.MALFUNCTION SYMPTOM TABLE
The table below lists the typical malfunction symptoms of the combination meter. These malfunctions can be
solved by the procedure in the section of the Malfunction Diagnosis.
Serial No.
MALFUNCTION SYMPTOM
1
The whole combination meter does not operate
2
Speedometer malfunction
3
Tachometer malfunction
4
Water temperature gauge malfunction
5
Fuel gauge malfunction
6
Odometer malfunction
175
II. DETAILED SOLUTION PROCEDURE
1. THE WHOLE COMBINATION METER
DOSE NOT OPERATE.
(a) Inspect fuse
1
Check fuse CLUSTER (10A) in the main fuse
box for continuity.
2
Check fuse AM (30A) in the main fuse box
for continuity.
3
Check fuse MAIN (80A) in the fuse box for
continuity.
Result and solution: If a certain fuse is burnt, replace a fuse
with the same capacity.
Ignition Switch
Main Fuse Box
Combined Meter Assembly
Battery
Fuse Box
176
(b) Inspect the combination meter connectors.
1
Inspect continuity
Disconnect the connector from the combination meter assembly
Inspect continuity between terminals
Standard:
2
Inspect voltage
Disconnect the connector from the combination meter assembly
Turn the ignition switch ON
Inspect voltage between terminals
Standard:
Result and solution:
Normal
Replace the combination meter assembly
Abnormal
Repair or replace the harness or connector
Tester connection
Condition
Standard condition
B4 - ground
Turn the ignition switch ON
10 – 14V
Tester connection
Condition
Standard condition
B7 - ground
Normal condition
Continuity
B8 - ground
Normal condition
Continuity
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.