DAF 95XF. Manual — part 242
5
Connecting accessories
CONNECTING ACCESSORIES
1-3
1.3 CONNECTING ACCESSORIES VIA THE ACCESSORY CONNECTOR
On the right-hand side, along the central printed
circuit, a 12-pole accessory connector (1) has
been installed (connector no. 385).
The supply voltage for this connector is
branched off from the power supply via the
fuses (2)
Attached to the connector are:
Pin 1
:
wire no. 1154
Pin 3
:
wire no. 1258
Pin 10
:
earth
Pin 12
:
earth
Maximum current consumption:
Pin 1
:
supply before contact, max. 25 A
Pin 3
:
supply after contact, max. 25 A
E500255
385
3
12
1
10
E500138
2
1
6
ǹ 0009
5
CONNECTING ACCESSORIES
Connecting accessories
1-4
1.4 OVERVIEW OF CONNECTION POINTS IN ROOF CONSOLE
Cab versions
1
2
3
K100442
1.
XL cab (Comfort cab)
2.
XH cab (Space cab)
3.
XC cab (Superspace cab)
6
ǹ 0009
5
Connecting accessories
CONNECTING ACCESSORIES
1-5
Figure showing XC-cab roof console
E500579
A
B
C
D
XC
XL + XH
D
B
A
Description
Used for cab
versions
A
24V (40A) connector (for microwave, fog lights, etc.).
XL + XH + XC
B
Passage tube
XL + XH + XC
C
12V connector for audio equipment (e.g. CB transmitter)
XC
D
Connector, overhead-box wiring (with 12V connection)
XL + XH + XC
6
ǹ 0009
5
CONNECTING ACCESSORIES
Connecting accessories
1-6
1.5 40A CONNECTOR
This connector (A) is a two-pole connector.
The supply voltage for this connector is
branched off from the power supply before
contact via fuse E168.
It is possible to connect a connector to a contact
block. This way you get a central connection
point for supply and earth.
E500329
A
E168
A038
1175
1000
M
E500225
E500566
1334294
6
ǹ 0009