DAF LF45, LF55 Series. Manual — part 27

©

2-13

VIC customer parameters

VIC

DAVIE XD diagnostics manual

4

T

he de

fa

ult

setting ca

n be mod

ifie

d

by

me

an

s

of

a

modification in

the

main menu. The

setting

s ar

e expla

ine

d in th

e table

b

e

lo

w.

VIC

c

u

sto

m

er

para

meter

c

o

de

Exp

la

n

atio

n

D

e

p

en

de

nc

es:

Notes

Minimum

va

lu

e to be

se

t:

Ma

ximum

value

to

b

e

set:

Grou

p 1

S

ettin

g

of the

e

n

ga

gi

ng c

ond

iti

o

n

s

for

th

e

PT

O

con

trol

fun

c

ti

on

fo

r PT

O 1 an

d/o

r PT

O 2

Th

ese se

ttin

gs ap

ply to ve

hicles eq

uipp

ed

with

AS

Tron

ic

.

1

-6

8/1-76

S

etti

ng used

to determi

n

e whethe

r the parkin

g brake

(parkin

g brake

signa

l) has i

nfl

uen

ce

on the

enga

gin

g of

the PTO.

The

setting

"n

ot a

ctive

" mea

ns

tha

t the

parkin

g

brake

(p

arking

brake

sign

al) h

as n

o i

nfl

uen

ce

on

the

enga

gin

g

of the PTO.

The

setting

"a

ctive

" me

ans

th

at the

pa

rki

ng

brake

(p

arking

brake sig

nal) h

as influ

ence o

n the en

gag

ing o

f

the

PT

O.

1

-6

9/1-77

S

etti

ng used

to determin

e the

in

fluen

ce of the pa

rki

ng

brake

(pa

rking brake

sig

nal

) on

the en

gag

ing of th

e

PTO. See

a

lso

1-68.

The

setti

ng "u

sed"

only a

llow

s th

e PT

O to b

e en

gage

d if

th

e pa

rki

ng b

rake

is ac

tivat

ed.

The

setting

"re

lease

d" onl

y al

lows th

e PTO

to be

enga

ged

if

th

e

parking

b

rake

is n

ot a

ctiva

te

d.

1

-7

0/1-78

S

etti

ng

of the ma

xi

mu

m eng

ine

spee

d a

t which

th

e PT

O

is eng

age

d.

1

-7

1/1-79

S

etti

ng of th

e ma

ximum

veh

icle spe

ed at which the PTO

is eng

age

d.

G

ro

u

p

2

S

etti

ng

o

f

th

e di

sen

ga

gi

ng

con

d

it

io

n

s for the

PT

O

con

trol

fun

c

ti

on

fo

r PT

O 1 an

d/o

r PT

O 2

Th

ese se

ttin

gs ap

ply to ve

hicles eq

uipp

ed

with

AS

Tron

ic

.

1

-7

3/1-81

S

etti

ng used

to determi

n

e whethe

r the parkin

g brake

(parkin

g brake sign

al) has in

flu

ence

on

the

d

iseng

agin

g

of

the

PT

O.

The

setting

"n

ot a

ctive

" mea

ns

tha

t the

parkin

g

brake

(p

arking

b

ra

ke si

gna

l)

h

as

n

o influe

nce on the

disen

gagi

ng

of the

PT

O.

The

setting

"a

ctive

" me

ans

th

at the

pa

rki

ng

brake

(p

arking

b

ra

ke si

gna

l)

h

as influe

nce on the dise

ngag

ing

of the PTO.

VIC

2-14

©

VIC customer parameters

DAVIE XD diagnostics manual

4

1

-7

4/1-82

S

etti

ng used

to determin

e the

in

fluen

ce of the pa

rki

ng

brake

(pa

rking

brake

sig

nal

)

on

the

di

senga

gin

g o

f the

PT

O.

The

setting

"u

sed" on

ly

a

llow

s the PTO to

be

disen

gage

d if

the pa

rki

ng brake is activated.

The

setting

"re

lease

d" onl

y al

lows th

e PTO

to be

disen

gage

d if

the pa

rki

ng

brake is not activated.

1

-3

2/1-83

S

etti

ng

of the ma

xi

mu

m eng

ine

spee

d a

t which

th

e PT

O

is dise

ngag

ed.

1

-7

5/1-84

S

etti

ng of th

e ma

ximum

veh

icle spe

ed at which the PTO

is dise

ngag

ed.

Setting

o

f th

e

FAG

tr

action

c

o

n

tro

l

T

h

is

setting

allo

ws

you

to d

eter

m

in

e whe

n

th

e F

A

G

tr

ac

tio

n co

ntro

l

mu

st be

d

is

enga

g

e

d

.

1

-2

7

Setti

ng

of

the

ve

hicle

spe

ed

for e

ngag

ing

a

nd

di

se

nga

ging

the

traction

control

.

The

3

0

km/h

settin

g

me

ans

th

at w

ith

a

veh

icle

spe

ed

exceedi

ng

30

km/h

the

traction

con

trol

can

not

be

acti

va

te

d; with

a

ve

hicle

spe

ed

belo

w

3

0

km/h, ho

wever,

the

traction

con

trol

ca

n

be

activated.

Oi

l level parameters

S

e

tt

ing

p

e

rmitt

in

g

c

o

m

p

en

sa

ti

on

o

f th

e

el

ec

tr

on

ic

oil level co

ntro

l

1

-2

3

Setti

ng pe

rmitting

compe

nsation

o

f the ele

ctron

icall

y

measu

re

d oil le

vel with th

e actu

al oil

le

vel in the en

gine

With a chang

e of

val

ue hig

her th

an 0 the level

is

co

mp

ensa

ted

u

pward

s; with a chang

e of

val

ue low

er

tha

n 0 (n

ega

tive

va

lue) the level

is

compe

nsated

down

w

ards

1

-2

4

Setti

ng pe

rmitting

compe

nsation

o

f the ele

ctron

icall

y

measu

re

d

oil

leve

l, de

pen

ding

o

n the

e

ngin

e i

nclin

ation.

T

his se

ttin

g is

in

tende

d fo

r coa

ch

a

ppli

cations for

examp

le, a

s he

re

the

e

ngi

ne

incli

nation

va

ries

in

compa

ris

on with th

e truck app

licatio

n

With a chang

e of

val

ue hig

her th

an 10

0

the

le

vel is

co

mp

ensa

ted

u

pward

s; with a chang

e of

val

ue low

er

tha

n 100

the le

ve

l is

co

mp

ensated

d

ownwa

rds

ESC par

amete

rs

Se

tti

n

g of the

sw

it

chi

n

g on

a

n

d

s

w

it

ch

in

g off

co

nd

itio

ns o

f t

h

e ECS-DC3 con

tro

l fun

c

ti

on

"(PT

O)

eng

in

e

sp

eed

co

ntro

l" via

the

en

gine

sp

eed

co

n

tr

o

l

app

lica

tio

n co

nn

ecto

r (A068

).

On

ly

with

ve

hicles

eq

uipp

ed

w

it

h

a

BE

or

CE

en

gi

ne

.

VIC

c

u

sto

m

er

para

meter

c

o

de

Exp

la

n

atio

n

D

e

p

en

de

nc

es:

Notes

Minimum

va

lu

e to be

se

t:

Ma

ximum

value

to

b

e

set:

©

2-15

VIC customer parameters

VIC

DAVIE XD diagnostics manual

4

1

-2

8

Setti

ng of the

b

rake ped

al so tha

t the control function

"e

ng

in

e

spe

ed

co

nt

ro

l"

is

sw

itch

ed

o

ff w

hen

th

e

bra

ke

pe

dal is ope

rate

d.

If "

not a

cti

ve

"

has

bee

n se

lected, th

e

b

rake ped

al is

igno

red. If "a

cti

ve

" h

as

been

se

lected, the

e

ngin

e

sp

eed

co

ntrol is

sw

itch

ed off an

d

sw

itch

ing

-o

n is

p

revented

when

the

brake

p

edal

is

op

erated.

1

-2

9

Setti

ng of the

cl

utch

p

edal

so

that th

e co

ntrol fu

ncti

on

"engine speed control"

is sw

itch

ed

o

ff w

hen

th

e

clu

tc

h

pe

dal is ope

rate

d.

If "no

t acti

ve" h

as be

en set, the cl

utch

ped

al i

s ign

ored;

if

"a

ctive

" h

as b

een

set, the

en

gin

e

sp

eed

con

tro

l i

s

sw

itch

ed off as soon

a

s

the clutch ped

al is ope

rate

d.

1

-3

0

Setti

ng of the

p

arking

bra

ke

so

tha

t th

e control function

"en

gin

e spe

ed

control"

is swi

tche

d o

ff wh

en

th

e pa

rking

brake

is

rele

ased

.

If "

not a

cti

ve

"

has

bee

n se

le

cted,

th

e p

arking

b

ra

ke

is

igno

red. If "a

cti

ve

" h

as

been

se

lected, the

e

ngin

e

sp

eed

co

ntrol is

sw

itch

ed off an

d

sw

itch

ing

-o

n is

p

revented

when

the

pa

rki

ng

brake

pe

dal

is

rele

ased.

VIC

c

u

sto

m

er

para

meter

c

o

de

Exp

la

n

atio

n

D

e

p

en

de

nc

es:

Notes

Minimum

va

lu

e to be

se

t:

Ma

ximum

value

to

b

e

set:

VIC

2-16

©

VIC customer parameters

4

DAVIE XD diagnostics manual