DAF LF45, LF55 Series. Manual — part 27
©
2-13
VIC customer parameters
VIC
DAVIE XD diagnostics manual
4
T
he de
fa
ult
setting ca
n be mod
ifie
d
by
me
an
s
of
a
modification in
the
main menu. The
setting
s ar
e expla
ine
d in th
e table
b
e
lo
w.
VIC
c
u
sto
m
er
para
meter
c
o
de
Exp
la
n
atio
n
D
e
p
en
de
nc
es:
Notes
Minimum
va
lu
e to be
se
t:
Ma
ximum
value
to
b
e
set:
Grou
p 1
S
ettin
g
of the
e
n
ga
gi
ng c
ond
iti
o
n
s
for
th
e
PT
O
con
trol
fun
c
ti
on
fo
r PT
O 1 an
d/o
r PT
O 2
Th
ese se
ttin
gs ap
ply to ve
hicles eq
uipp
ed
with
AS
Tron
ic
.
1
-6
8/1-76
S
etti
ng used
to determi
n
e whethe
r the parkin
g brake
(parkin
g brake
signa
l) has i
nfl
uen
ce
on the
enga
gin
g of
the PTO.
The
setting
"n
ot a
ctive
" mea
ns
tha
t the
parkin
g
brake
(p
arking
brake
sign
al) h
as n
o i
nfl
uen
ce
on
the
enga
gin
g
of the PTO.
The
setting
"a
ctive
" me
ans
th
at the
pa
rki
ng
brake
(p
arking
brake sig
nal) h
as influ
ence o
n the en
gag
ing o
f
the
PT
O.
1
-6
9/1-77
S
etti
ng used
to determin
e the
in
fluen
ce of the pa
rki
ng
brake
(pa
rking brake
sig
nal
) on
the en
gag
ing of th
e
PTO. See
a
lso
1-68.
The
setti
ng "u
sed"
only a
llow
s th
e PT
O to b
e en
gage
d if
th
e pa
rki
ng b
rake
is ac
tivat
ed.
The
setting
"re
lease
d" onl
y al
lows th
e PTO
to be
enga
ged
if
th
e
parking
b
rake
is n
ot a
ctiva
te
d.
1
-7
0/1-78
S
etti
ng
of the ma
xi
mu
m eng
ine
spee
d a
t which
th
e PT
O
is eng
age
d.
1
-7
1/1-79
S
etti
ng of th
e ma
ximum
veh
icle spe
ed at which the PTO
is eng
age
d.
G
ro
u
p
2
S
etti
ng
o
f
th
e di
sen
ga
gi
ng
con
d
it
io
n
s for the
PT
O
con
trol
fun
c
ti
on
fo
r PT
O 1 an
d/o
r PT
O 2
Th
ese se
ttin
gs ap
ply to ve
hicles eq
uipp
ed
with
AS
Tron
ic
.
1
-7
3/1-81
S
etti
ng used
to determi
n
e whethe
r the parkin
g brake
(parkin
g brake sign
al) has in
flu
ence
on
the
d
iseng
agin
g
of
the
PT
O.
The
setting
"n
ot a
ctive
" mea
ns
tha
t the
parkin
g
brake
(p
arking
b
ra
ke si
gna
l)
h
as
n
o influe
nce on the
disen
gagi
ng
of the
PT
O.
The
setting
"a
ctive
" me
ans
th
at the
pa
rki
ng
brake
(p
arking
b
ra
ke si
gna
l)
h
as influe
nce on the dise
ngag
ing
of the PTO.
VIC
2-14
©
VIC customer parameters
DAVIE XD diagnostics manual
4
1
-7
4/1-82
S
etti
ng used
to determin
e the
in
fluen
ce of the pa
rki
ng
brake
(pa
rking
brake
sig
nal
)
on
the
di
senga
gin
g o
f the
PT
O.
The
setting
"u
sed" on
ly
a
llow
s the PTO to
be
disen
gage
d if
the pa
rki
ng brake is activated.
The
setting
"re
lease
d" onl
y al
lows th
e PTO
to be
disen
gage
d if
the pa
rki
ng
brake is not activated.
1
-3
2/1-83
S
etti
ng
of the ma
xi
mu
m eng
ine
spee
d a
t which
th
e PT
O
is dise
ngag
ed.
1
-7
5/1-84
S
etti
ng of th
e ma
ximum
veh
icle spe
ed at which the PTO
is dise
ngag
ed.
Setting
o
f th
e
FAG
tr
action
c
o
n
tro
l
T
h
is
setting
allo
ws
you
to d
eter
m
in
e whe
n
th
e F
A
G
tr
ac
tio
n co
ntro
l
mu
st be
d
is
enga
g
e
d
.
1
-2
7
Setti
ng
of
the
ve
hicle
spe
ed
for e
ngag
ing
a
nd
di
se
nga
ging
the
traction
control
.
The
3
0
km/h
settin
g
me
ans
th
at w
ith
a
veh
icle
spe
ed
exceedi
ng
30
km/h
the
traction
con
trol
can
not
be
acti
va
te
d; with
a
ve
hicle
spe
ed
belo
w
3
0
km/h, ho
wever,
the
traction
con
trol
ca
n
be
activated.
Oi
l level parameters
S
e
tt
ing
p
e
rmitt
in
g
c
o
m
p
en
sa
ti
on
o
f th
e
el
ec
tr
on
ic
oil level co
ntro
l
1
-2
3
Setti
ng pe
rmitting
compe
nsation
o
f the ele
ctron
icall
y
measu
re
d oil le
vel with th
e actu
al oil
le
vel in the en
gine
With a chang
e of
val
ue hig
her th
an 0 the level
is
co
mp
ensa
ted
u
pward
s; with a chang
e of
val
ue low
er
tha
n 0 (n
ega
tive
va
lue) the level
is
compe
nsated
down
w
ards
1
-2
4
Setti
ng pe
rmitting
compe
nsation
o
f the ele
ctron
icall
y
measu
re
d
oil
leve
l, de
pen
ding
o
n the
e
ngin
e i
nclin
ation.
T
his se
ttin
g is
in
tende
d fo
r coa
ch
a
ppli
cations for
examp
le, a
s he
re
the
e
ngi
ne
incli
nation
va
ries
in
compa
ris
on with th
e truck app
licatio
n
With a chang
e of
val
ue hig
her th
an 10
0
the
le
vel is
co
mp
ensa
ted
u
pward
s; with a chang
e of
val
ue low
er
tha
n 100
the le
ve
l is
co
mp
ensated
d
ownwa
rds
ESC par
amete
rs
Se
tti
n
g of the
sw
it
chi
n
g on
a
n
d
s
w
it
ch
in
g off
co
nd
itio
ns o
f t
h
e ECS-DC3 con
tro
l fun
c
ti
on
"(PT
O)
eng
in
e
sp
eed
co
ntro
l" via
the
en
gine
sp
eed
co
n
tr
o
l
app
lica
tio
n co
nn
ecto
r (A068
).
On
ly
with
ve
hicles
eq
uipp
ed
w
it
h
a
BE
or
CE
en
gi
ne
.
VIC
c
u
sto
m
er
para
meter
c
o
de
Exp
la
n
atio
n
D
e
p
en
de
nc
es:
Notes
Minimum
va
lu
e to be
se
t:
Ma
ximum
value
to
b
e
set:
©
2-15
VIC customer parameters
VIC
DAVIE XD diagnostics manual
4
1
-2
8
Setti
ng of the
b
rake ped
al so tha
t the control function
"e
ng
in
e
spe
ed
co
nt
ro
l"
is
sw
itch
ed
o
ff w
hen
th
e
bra
ke
pe
dal is ope
rate
d.
If "
not a
cti
ve
"
has
bee
n se
lected, th
e
b
rake ped
al is
igno
red. If "a
cti
ve
" h
as
been
se
lected, the
e
ngin
e
sp
eed
co
ntrol is
sw
itch
ed off an
d
sw
itch
ing
-o
n is
p
revented
when
the
brake
p
edal
is
op
erated.
1
-2
9
Setti
ng of the
cl
utch
p
edal
so
that th
e co
ntrol fu
ncti
on
"engine speed control"
is sw
itch
ed
o
ff w
hen
th
e
clu
tc
h
pe
dal is ope
rate
d.
If "no
t acti
ve" h
as be
en set, the cl
utch
ped
al i
s ign
ored;
if
"a
ctive
" h
as b
een
set, the
en
gin
e
sp
eed
con
tro
l i
s
sw
itch
ed off as soon
a
s
the clutch ped
al is ope
rate
d.
1
-3
0
Setti
ng of the
p
arking
bra
ke
so
tha
t th
e control function
"en
gin
e spe
ed
control"
is swi
tche
d o
ff wh
en
th
e pa
rking
brake
is
rele
ased
.
If "
not a
cti
ve
"
has
bee
n se
le
cted,
th
e p
arking
b
ra
ke
is
igno
red. If "a
cti
ve
" h
as
been
se
lected, the
e
ngin
e
sp
eed
co
ntrol is
sw
itch
ed off an
d
sw
itch
ing
-o
n is
p
revented
when
the
pa
rki
ng
brake
pe
dal
is
rele
ased.
VIC
c
u
sto
m
er
para
meter
c
o
de
Exp
la
n
atio
n
D
e
p
en
de
nc
es:
Notes
Minimum
va
lu
e to be
se
t:
Ma
ximum
value
to
b
e
set:
VIC
2-16
©
VIC customer parameters
4
DAVIE XD diagnostics manual
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст