Mitsubishi Grandis. Manual — part 682
KEYLESS ENTRY SYSTEM
BODY
42-56
NOTE:
.
•
The customisation function allows you to
change the answerback setting as follows.
Prior to that check, confirm which setting is
activated.
•
The hazard warning lights flash once
when locked and twice when unlocked.
The room lamp flashes once when locked
and illuminates for 15 seconds when
unlocked (default setting).
•
The hazard warning lights flash once
when locked and do not flash when
unlocked. The room lamp flashes once
when locked and illuminates for 15
seconds when unlocked.
•
The hazard warning lights do flash when
locked and flash twice when unlocked.
The room lamp flashes once when locked
and illuminates for 15 seconds when
unlocked.
•
The hazard warning lights do not flash
when both locked and unlocked. The room
lamp flashes once when locked and
illuminates for 15 seconds when unlocked.
•
The hazard warning lights flash twice
when locked and once when unlocked.
The room lamp flashes twice when locked
and illuminates for 15 seconds when
unlocked.
•
The hazard warning lights flash twice
when locked and do not flash when
unlocked. The room lamp flashes twice
when locked and illuminates for 15
seconds when unlocked.
•
The hazard warning lights do flash when
locked and flash once when unlocked.
The room lamp flashes twice when locked
and illuminates for 15 seconds when
unlocked.
•
The hazard warning lights do not flash
when both locked and unlocked. The room
lamp flashes twice when locked and
illuminates for 15 seconds when unlocked.
MULTI-MODE KEYLESS ENTRY
FUNCTION INSPECTION
M1428004100049
Check that the transmitter operates the electric
outside mirrors. If they do not operate, carry out
troubleshooting. Refer to GROUP 54B,
Troubleshooting
Troubleshooting
.
KEYLESS ENTRY SYSTEM TIMER LOCK
FUNCTION INSPECTION
M1428004000194
Attempt to unlock the doors and the tailgate by using
the transmitter. If the doors and the tailgate are not
locked within 30 seconds, carry out troubleshooting.
Note that the doors and the tailgate will not be locked
if the ignition key is inserted within the 30-second
period, one of the doors or the tailgate is opened, or
the multi-mode keyless entry function is triggered.
Refer to GROUP 54B, Troubleshooting
refer to GROUP 54C, Troubleshooting
.
NOTE: The customisation function allows you to
change the keyless entry system timer lock period
from 30 seconds (default setting) to 60, 120 or 180
seconds. Prior to the check, confirm which setting is
activated.
ENABLING/DISABLING THE
ANSWERBACK FUNCTION
M1428003200366
If the keyless entry system locks or unlocks the
doors, the room lamp flashes or illuminates, the
hazard warning lamp flashes (hazard answerback
function). The hazard answerback function can be
enabled or disabled according to the following
procedure:
ENABLING/DISABLING THE HAZARD
ANSWERBACK FUNCTION
The hazard answerback function can be enabled or
disabled by one of the two following procedures.
HOW TO ADJUST HAZARD
ANSWERBACK WHEN THE
TRANSMITTER IS USED TO LOCK
DOORS
1. Remove the ignition key.
2. Push the ”UNLOCK” button and then push the
”LOCK“ button within 4 seconds to 10 seconds.
3. Release the ”LOCK” button within 10 seconds
after Step 2 and then release the “UNLOCK”
button. The ETACS-ECU buzzer will sound,
indicating that the hazard answerback function
can be enabled or disabled when the doors are
locked.
• Enable the hazard answerback function
when the doors are locked: The
ETACS-ECU buzzer will sound once.
• Disable the hazard answerback function
when the doors are locked: The
ETACS-ECU buzzer will sound twice.
KEYLESS ENTRY SYSTEM
BODY
42-57
HOW TO ADJUST HAZARD
ANSWERBACK WHEN THE
TRANSMITTER IS USED TO UNLOCK
DOORS
1. Remove the ignition key.
2. Push the ”UNLOCK” button and then push the
”LOCK“ button within 4 seconds to 10 seconds.
3. Release the ”UNLOCK” button within 10 seconds
after Step 2 and then release the “LOCK” button.
The ETACS-ECU buzzer will sound, indicating
that the hazard answerback function can be
enabled or disabled when the door are unlocked.
• Enable the hazard answerback function
when the doors are unlocked: The
ETACS-ECU buzzer will sound once.
• Disable the hazard answerback function
when the doors are unlocked: The
ETACS-ECU buzzer will sound twice.
HOW TO REGISTER SECRET CODE
M1428001000474
Each individual secret code is registered inside the
transmitter, and so it is necessary to resister these
codes with the EEPROM inside the receiver in the
following cases.
• When the transmitter or ETACS-ECU is replaced
• If more transmitters are to be used
• If it appears that a problem is occurring because
of faulty registration of a code.
A maximum of four different codes can be stored in
the EEPROM memory (four different transmitters can
be used). When the code for the first transmitter is
registered, the previously registered codes for all
transmitters are cleared. Therefore, if you are using
four transmitters or are adding more transmitters, the
codes for all transmitters must be registered at the
same time.
WHEN THE SPECIAL TOOL V.C.I.
(MB991824) IS USED
1. Check that the doors lock normally when the key
is used.
2. Insert the ignition key.
CAUTION
Before connecting or disconnecting the V.C.I.,
turn the ignition switch to the "LOCK" (OFF)
position.
3. Connect the V.C.I. to the diagnosis connector.
4. Within 10 seconds after turning the V.C.I. power
switch to the "ON" position, press the hazard
switch six times.
NOTE: Once the process is completed six times,
then it will operate with all doors and tailgate lock
and unlock operations once and then go to the
save mode.
NOTE: The hazard warning lamp switch is turned
on and off alternately whenever it is pushed.
5. Press the transmitter switch, and then press it two
times within 10 seconds of the first press. This will
register the code.
6. Once the program is saved, it will operate once
with the all doors and tailgate lock and unlock
operations.
AC310120
AC310861
AB
MB991910
MB991824
16-Pin
ACX00571
Connect V. C. I. and turn
the V. C. I. power supply
switch ON.
Within 10 seconds
Hazard
warning
switch
ON
OFF
1
2
3
4
5
6
AJ
KEYLESS ENTRY SYSTEM
BODY
42-58
7. If you are using two or more transmitters or have
added a second transmitter, the same registration
procedure should be carried out within one minute
after registering the code for the first transmitter.
8. Registration mode will be cancelled under the
following conditions:
• When the secret code for four transmitters has
been registered;
• When one minute has passed after registration
mode started;
• When the V.C.I. is disconnected from the
diagnosis connector;
• When the key is removed from the key cylinder;
9. After the registration is completed, remove the
ignition key and close all the doors, and then
check that the keyless entry system operates
normally.
WHEN THE MUT-III AND SWS MONITOR
IS USED
1. Check that the doors lock normally when the
ignition key is inserted into the door key cylinder
and turned.
2. Insert the ignition key in the ignition switch.
CAUTION
Before connecting or disconnecting the MUT-III
and SWS monitor, turn the ignition switch to the
"LOCK" (OFF) position.
3. Connect the SWS monitor to the MUT-III. Refer to
GROUP 54C, How to Connect The SWS Monitor
4. Connect the MUT-III to the diagnosis connector.
5. Select "Interactive Diagnosis" from the main
menu.
6. Select "System Select" from "Interactive
Diagnosis".
7. Select "BODY" from the upper tab on "System
Select" window.
8. Select "SWS" from "BODY".
9. Select "SWS Monitor" from "SWS".
10.If "New communication between doors" is
selected from "SWS monitor", the display screen
will be changed. Select "Keyless Entry" from that
screen.
AC311058
MB991910
MB991806
(SWS monitor)
MB991827
AB
MB991824
MB991960
16-Pin
KEYLESS ENTRY SYSTEM
BODY
42-59
11.Select "Keyless ID Regist" from "Keyless Entry"
items.
12.Press the YES key to clear encrypted codes for
all the current registered transmitters.
13.Push the hazard warning lamp switch to clear all
the encrypted codes completely.
14.Push the switch of the transmitter to be registered
consecutively three times. If another transmitter is
registered, push the switch of that transmitter
again consecutively three times.
15.Return to the previous step.
16.Select "Recept Inspect" from "Keyless Entry"
items.
17.Push the transmitter switch. If the transmitter can
receive signal normally, the screen will show
variation of the received signals and whether the
transmitter switch has been registered or not.
NOTE: For the keyless entry system, the signal
reception can be examined regardless of whether
the transmitter is registered or not.
18.Return to the main menu and complete.
19.Remove the MUT-III.
20.Disconnect the SWS monitor.
21.Check that the keyless entry system works
normally.
TRANSMITTER
DISASSEMBLY AND REASSEMBLY
M1428002800097
DISASSEMBLY SERVICE POINT
<<A>> BATTERY REMOVAL
CAUTION
Do not allow water or dust to enter the inside of
the transmitter assembly when it is open. Also,
do not touch the precision electronic device.
Post-installation operation
• Transmitter operation check
AC310838
AC303199
AC304118
1
2
3
AB
Disassembly steps
1.
Screw
<<A>>
>>A<<
2.
Battery
3.
Master key assembly
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст