Mitsubishi Montero Sport (2004+). Manual — part 599
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-23
INSPACTION PROCEDURE 10: Warm Air does not Go Out From the Air Outlets
DIAGNOSIS
STEP 1. Check the water shut motor
CAUTION
When the motor stops, disconnect battery cable.
Follow the table below to check the water shut motor for correct
operation.
Q: Does water shut motor work normally?
YES : Go to Step 2.
NO : Replace. Then go to Step 3.
STEP 2. Check the water shut valve controller continuity.
NOTE: When the temperature control knob is at the "MAX
COOL" position, power is supplied to the water shut relay.
LEVER POSITION BATTERY
CONNECTION
LEVER
OPERATION
At the open position
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
The lever moves
from the open
position to the
closed position
At the close
position
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 2 to the
negative battery
terminal
The lever moves
from the closed
position to the open
position
AC306351AB
OPEN
SIDE
CLOSE
SIDDE
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-24
Follow the table below to check the water shut valve controller
for continuity.
Q: Is the water shut valve controller in good condition?
YES : Go to Step 3.
NO : Replace. Then go to Step 3.
STEP 3. Check symptoms.
Q: Is the cool air discharged?
YES : This diagnosis is complete. (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to Introduction, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1 .
TEMPERATURE
CONTROL KNOB
POSITION
BATTERY CONNECTION TESTER
CONNECTION
SPECIFIED
CONDITION
At the "MAX
COOL" position
• Connect
terminal 7 to
the positive
battery
terminal
• Connect
terminal 3 to
the negative
battery
terminal
3
− 8
Less than 2
ohms
At the other than
"MAX COOL"
position
• Connect
terminal 7 to
the positive
battery
terminal
• Connect
terminal 3 to
the negative
battery
terminal
1
− 3
Less than 2
ohms
AC002849
DEFROSTER
SWITCH
AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-25
INSPECTION AT THE AUTOMATIC COMPRESSOR CONTROLLER TERMINAL
M1552010300602
1
2 3 4 5 6
7 8
9 10
11 12 13 14 15 16 17 18 19 20
AC000026
AB
TERMINAL
NO.
CHECK ITEM
CHECKING REQUIREMENTS
NORMAL CONDITION
1
IG2 power supply
Ignition switch ON
Battery positive voltage
2
A/C switch input
A/C switch OFF or blower switch OFF
0 V
A/C switch ON Ignition switch ON
Blower switch ON
Battery positive voltage
4
Air conditioning output
A/C compressor clutch relay OFF
0 V
A/C compressor clutch relay ON
Battery positive voltage
8
Ground
At all times
Continuity
9
Ground
At all times
Continuity
14
Air thermo sensor power
supply
At all times
4.8
− 5.2 V
15
Air thermo sensor input
Sensor temperature 25
°C (77°F) (4 kΩ) 2.3 − 2.9 V
16
Outside air temperature
sensor power supply
At all times
4.8
− 5.2 V
17
Outside air temperature
sensor input
Sensor temperature 25
°C (77°F) (4 kΩ) 2.3 − 2.9 V
18
Backup power supply
At all times
Battery positive voltage
19
Outside air temperature
output
Sensor temperature 15
°C (52°F) or
more
Battery positive voltage
Sensor temperature 18
°C (64°F) or
more
2 V or more
SPECIAL TOOLS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-26
SPECIAL TOOLS
M1552000600248
TOOL
TOOL NUMBER AND
NAME
SUPER SESSION
APPLICATION
MB991367
Special spanner
MB991367-01
Armature mounting nut of
compressor removal and
installation
MB991386
Pin
MIT217213
MB990784
Ornament remover
General service tool
Meter bezel assembly removal
B991367
MB990784
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст